ACL Commands
78-21075-01 Command Line Interface Reference Guide
Parameters
time-range-name—Specifies the name for the time range. (Range: 1–32
characters)
Default Configuration
No time range is defined
Command Mode
Global Configuration mode
User Guidelines
After adding the name of a time range with this command, use the
periodic
commands to actually configure the time-range. Multiple periodic
commands are allowed in a time range. Only one absolute command is allowed.
If a time-range command has both absolute and periodic values specified, then
the periodic items are evaluated only after the absolute start time is reached, and
are not evaluated again after the absolute end time is reached.
All time specifications are interpreted as local time.
To ensure that the time range entries take effect at the desired times, the software
clock should be set by the user or by SNTP. If the software clock is not set by the
user or by SNTP, the time range ACEs are not activated.
The user cannot delete a time-range that is bound to any features, such as ACLs.
When a time range is defined, it can be used in the following commands:
•
dot1x port-control
•
power inline
•
permit (IP)
•
deny (IP)
•
permit (IPv6)
•
deny (IPv6)
•
permit (MAC)
•
deny (MAC)
48
absolute
and
787