Removing and Replacing FRUs from the Cisco ASR 1000 Series Routers
The following figure shows the DC power supply terminal block with the order of installing the screws and washers
on the ground lug.
Figure 297: Cisco ASR 1013 Router DC Power Supply Ground Lug Installation
1
2
3
Step 9
Tighten the Kepnut screw (use the screwdriver to tighten the ground screw in the terminal block to a torque of 20+/–2
in-lbs / 2 per.) and repeat the same steps for the negative wires.
Note
Secure the wires coming in from the terminal block so that they cannot be disturbed by casual contact.
Step 10
Use tie wraps to secure the wires, so that the wires are not pulled from the terminal block by casual contact. Ti-wrap
studs are located below the power supply terminal block.
Removing and Replacing a DC Power Supply in Cisco ASR 1013 Router
DC power supply
grounding stud with wire
Grounding screws
DC power supply ground
symbol
Cisco ASR 1000 Series Router Hardware Installation Guide
4
5
—
Flat washer
Kepnut screw
—
597