Cisco ASR 1002 Router +24 VDC Power Supply
The +24 VDC power supply uses a spring-loaded terminal block. The input terminal block requires maximum
8AWG multi-strand wiring to support input current. The terminal block is compliant with safety agencies'
guidelines and electrical requirements of the supply. Use the tie wraps to dress the input cable wires; there
are two tie wrap tabs on the +24 VDC power supply. The +24 VDC power supply unit is secured into the
system chassis with two captive screws mounted on the faceplate.
Cisco ASR 1002 Router +24 VDC Power Supply LEDs and Connector
The following figure shows the +24 VDC power supplies at the rear of the Cisco ASR 1002 Router. The Cisco
ASR 1002 Router supports two +24 VDC power supplies.
Figure 18: Cisco ASR 1002 Router Rear View With +24 VDC Power Supply
1
2
3
4
5
Cisco ASR 1000 Series Router Hardware Installation Guide
72
+24 VDC terminal block
6
Positive (+) lead
7
Negative (-) lead
8
Ground (GND) lead
9
Power supply LEDs
—
Cisco ASR 1000 Series Routers Component Overview
Standby/On switch
Captive fastener
Power supply tabs
+27 VDC INPUT label
—