Removing and Replacing FRUs from the Cisco ASR 1000 Series Routers
Removing and Replacing the Cisco ASR 1013 Router Power
Supplies
The Cisco ASR 1013 Router contains power supplies that are field replaceable units. This section contains
the following topics:
Removing and Replacing an AC Power Supply in Cisco ASR 1013 Router
This section provides information about removing and replacing an AC power supply in the Cisco ASR 1013
Router.
Removing the AC Power Supply from Cisco ASR 1013 Router
Because of the power supply redundancy, there is no need to power off the Cisco ASR 1013 Router before
removing one of the AC power supplies.
The Cisco ASR 1013 Router has two of the same type power supplies in power supply slot 0 and power supply
slot 1.
To remove the Cisco ASR 1013 Router AC power supply that is not operating normally (and then replace the
AC power supply within five minutes), follow this procedure:
SUMMARY STEPS
1. Slip on the ESD-preventive wrist strap that was included in the accessory kit.
2. Before you turn off a power supply, make certain the chassis is grounded.
3. Turn the power supply standby switch to the Standby position. See the following figure.
4. Unplug the power cable from the AC inlet on the back of the power supply and the power source.
5. Unscrew the power supply captive screws.
6. Grasping the power supply handles, pull the power supply from the chassis.
7. Replace the AC power supply within five minutes.
Removing and Replacing the Cisco ASR 1013 Router Power Supplies
Cisco ASR 1000 Series Router Hardware Installation Guide
587