Denied Counter: 0
Absent Counter: 0
Invalid Signature Counter: 0
The following table describes the fields shown in the display:
Field
Description
Power
Inline power sourcing equipment operational
status.
Nominal Power
Inline power sourcing equipment nominal
power in Watts.
Consumed
Measured usage power in Watts.
Power
Usage Threshold
Usage threshold expressed in percent for
comparing the measured power and initiating
an alarm if threshold is exceeded.
Traps
Indicates if inline power traps are enabled.
Port
Ethernet port number.
Powered device
Description of the powered device type.
State
Indicates if the port is enabled to provide
power. The possible values are Auto or Never.
Priority
Port inline power management priority. The
possible values are Critical, High or Low.
Status
Power operational state. The possible values
are On, Off, Test-Fail, Testing, Searching or Fault.
Class
Power consumption classification of the
powered device.
Overload
Counts the number of overload conditions
Counter
detected.
Short Counter
Counts the number of short conditions
detected.
Denied Counter
Counts the number of times power was denied.
Absent Counter
Counts the number of times power was
removed because powered device dropout
was detected.
Invalid Signature
Counts the number of times an invalid signature
Counter
of a powered device was detected.
Inrush Test
Displays whether the inrush test is enabled or
disabled.
Power over Ethernet (PoE) Commands