hit counter script

Cisco ASR 1000 series Hardware Installation Manual page 301

Aggregation services routers
Table of Contents

Advertisement

Chapter 10
Cisco ASR 1002-X Router Overview and Installation
Table 10-5
Table 10-5
Cisco ASR 1002-X Router +24 VDC Power Supply LEDs
LED Label
LED
OUTPUT FAIL
Power supply activity
INPUT OK
A bicolor LED indicates
the presence of input
voltage
FAN OK
A bicolor LED indicates
the power supply fan
status
+24 VDC Power System Input for the Cisco ASR 1002-X Router
The +24 VDC power supply operates within specification between +21 VDC and +36 VDC continuously
after the power supply DC input is turned on. The power supply measures the input voltage at the power
supply terminals and turns off the supply when the input voltage reaches 19.0 V +/- 0.5 V when this low
voltage threshold is reached, the power supply does not resume operation until the input voltage reaches
20.0 V +/- 0.5 V. When the turn-on threshold of 20 V is reached, then the +24 VDC power supply meets
all specification requirements down to the low voltage threshold of 19 V (+/- tolerance).
OL-13208-11
shows the definitions of the Cisco ASR 1002-X Router +24 VDC power supply LEDs.
Color
Red
Green
Amber
Green
Red
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation Guide
Description
When the LED is off, it signals that the +24 VDC output
voltage is within the normal operating range. Output
voltage between the minimum limit and maximum limit
will not create an output fail alarm, but output voltages
below the minimum limit or above the maximum limit
will create an Output Fail alarm.
When you turn the power supply on, LED turns red for
two to three seconds to test the LED operation before
going off.
The LED turns green to signal that voltage is > or = to 20
VDC at turn-on and the voltage reduces to 19.0VDC (+/-
0.5 V tolerance).
The LED turns to amber when the input voltage is active
and is reduced to 16.0 VDC and indicates that a voltage
on the terminal block is still present. The LED remains
amber and is active until around 10 V. The LED should be
OFF below 15.8 VDC.
The LED turns to green when all fans are operational.
The LED turns to red when a fan failure is detected.