No Ring-Redundancy Hrpobserver; Ring-Redundancy Mode - Siemens SCALANCE XC-200 Configuration Manual

Simatic net command line interface industrial ethernet switches
Hide thumbs Also See for SCALANCE XC-200:
Table of Contents

Advertisement

Layer 2 management protocols
8.4 Ring redundancy and standby connection
Further notes
You disable the observer with the no ring-redundancy hrpobserver command.
You can display the status of this function and other information with the show ring-
redundancy command.
8.4.5.3

no ring-redundancy hrpobserver

Description
With this command, you disable the observer.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameter assignment:
no ring-redundancy hrpobserver
Result
The observer is disabled.
Further notes
You enable the observer with the ring-redundancy hrpobserver command.
You can display the status of this function and other information with the show ring-
redundancy command.
8.4.5.4

ring-redundancy mode

Description
With this command, you enable the ring redundancy function on a device.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
396
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06

Advertisement

Table of Contents
loading

Table of Contents

Save PDF