___________________ Introduction ___________________ Safety notices ___________________ SIMATIC NET Description of the device ___________________ Installation Industrial Ethernet switches SCALANCE XR-300WG ___________________ Connecting up ___________________ Upkeep and maintenance Operating Instructions ___________________ Technical specifications ___________________ Dimension drawings ___________________ Approvals 05/2017 C79000-G8976-C454-01...
Page 2
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Table of contents Introduction ............................. 5 Safety notices ............................11 Security recommendations ..................... 12 Description of the device ........................17 Product overview ........................17 3.1.1 Accessories ..........................19 Device views ........................... 20 3.2.1 Device view of a 24 VDC variant .................... 20 3.2.2 Device view of 240 VAC variant .....................
Page 4
Table of contents Upkeep and maintenance ........................47 Downloading new firmware using TFTP without WBM and CLI ..........47 Restoring the factory settings ....................48 Technical specifications ........................49 Technical specifications of the SCALANCE XR324WG ............49 7.1.1 24 VDC variant ........................49 7.1.2 240 VAC variant ........................
Introduction Purpose of the Operating Instructions These operating instructions support you when installing and connecting up devices of the SCALANCE XR-300WG product group. The configuration and the integration of the devices in a network are not described in these operating instructions. Validity of the Operating Instructions These operating instructions apply to the following devices: ●...
Page 6
● On the data medium that ships with some products: – Product CD / product DVD – SIMATIC NET Manual Collection ● On the Internet pages of Siemens Industry Online Support under the following entry IDs: – 27069465 (http://support.automation.siemens.com/WW/view/en/27069465) Industrial Ethernet / PROFINET Industrial Ethernet System Manual –...
Page 7
● On the Internet under the following address: 50305045 (http://support.automation.siemens.com/WW/view/en/50305045) Catalogs You will find the article numbers for the Siemens products of relevance here in the following catalogs: ● SIMATIC NET Industrial Communication / Industrial Identification, catalog IK PI ● SIMATIC Products for Totally Integrated Automation and Micro Automation, catalog ST 70 ●...
Page 8
In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions only form one element of such a concept. Customer is responsible to prevent unauthorized access to its plants, systems, machines and networks.
Page 9
Use of product versions that are no longer supported, and failure to apply latest updates may increase customer’s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under https://support.industry.siemens.com/cs/ww/en/ps/15247/pm...
Safety notices Read the safety notices Note the following safety notices. These relate to the entire working life of the device. You should also read the safety notices relating to handling in the individual sections, particularly in the sections "Installation" and "Connecting up". CAUTION To prevent injury, read the manual before use.
● Keep the firmware up to date. Check regularly for security updates for the device. You will find information on this on the Internet pages Industrial Security (http://www.siemens.com/industrialsecurity). ● Inform yourself regularly about security recommendations by Siemens ProductCERT (http://www.siemens.com/cert/en/cert-security-advisories.htm). ● Only activate protocols that you require to use the device.
Page 13
Safety notices 2.1 Security recommendations ● The option of VLAN structuring provides protection against DoS attacks and unauthorized access. Check whether this is practical or useful in your environment. ● Use a central logging server to log changes and accesses. Operate your logging server within the protected network area and check the logging information regularly.
Page 14
Safety notices 2.1 Security recommendations Secure/non-secure protocols and services ● Avoid or disable non-secure protocols and services, for example HTTP, Telnet and TFTP. For historical reasons, these protocols are available, however not intended for secure applications. Use non-secure protocols on the device with caution. ●...
Page 15
Safety notices 2.1 Security recommendations ● Use the configuration options of the interfaces, e.g. the "Edge Type". ● Configure the receive ports so that they discard all untagged frames ("Tagged Frames Only"). Available protocols The following list provides you with an overview of the open protocol ports. The table includes the following columns: ●...
Page 16
Safety notices 2.1 Security recommendations Protocol Port Port status Factory setting Authentication Encryption EtherNet/IP TCP/44818, Open (when con- Closed UDP/2222, figured) (Open with Ether- UDP/44818 net/IP variants) DHCP UDP/67, Open (when con- Closed UDP/68 figured) SCALANCE XR-300WG Operating Instructions, 05/2017, C79000-G8976-C454-01...
Description of the device Product overview Article numbers Device Properties Article number SCALANCE 24 VDC variant 6GK5 324-0BA00-2AR3 XR324WG 24 x 10/100 Mbps RJ-45 ports • 2 x 24 VDC, connector for the power supply on the front • 240 VAC variante 6GK5 324-0BA00-3AR3 24 x 10/100 Mbps RJ-45 ports •...
Page 18
Description of the device 3.1 Product overview Device Properties Article number 24 VDC variant (GE) 6GK5 328-4SS00-2AR3 24 x 10/100/1000 Mbps RJ-45 ports • 4 x combo ports (4 x 10/100/1000 Mbps RJ-45 ports/4 x pluggable • transceiver slots with 1000 Mbps) 2 x 24 VDC, connector for the power supply on the front •...
Description of the device 3.1 Product overview 3.1.1 Accessories The following accessories are available for SCALANCE XR-300WG: Cable Component Description Article number Connecting Preassembled, serial cable with RJ-11 and RS-232 6GK5 980-3BB00-0AA5 cable plug, (RJ-11/RS- Length: 3 m 232) pack of 1 Power cable Type Description...
Description of the device 3.2 Device views Note Restriction for pluggable transceivers The maximum ambient temperature changes if you use pluggable transceivers: • If you use pluggable transceivers of the types LH, LH+ or ELH, the maximum ambient temperature is reduced to 50 °C. For the values of the ambient temperature without pluggable transceivers, refer to the section "Technical specifications (Page 49)".
Description of the device 3.3 LED display 3.2.2 Device view of 240 VAC variant The following figure shows an overview of the components of a 240 VAC variant of a SCALANCE XR-300WG based on the example of a SCALANCE XR328-4C WG. ①...
Description of the device 3.3 LED display 3.3.2 "RM" LED The "RM" LED indicates whether or not the device is a redundancy manager and whether or not the ring is operating free of error. LED color LED status Meaning The device is not a redundancy manager. Green The device is a redundancy manager.
Description of the device 3.4 RESET button Pluggable transceiver slots There is an LED for each plug-in transceiver slot. LED color LED status Meaning Green Link exists Yellow Flashing Data transfer at the port No link exists RESET button WARNING EXPLOSION HAZARD Do not press the RESET button if there is a potentially explosive atmosphere.
Page 24
Description of the device 3.4 RESET button Requirement ● The device is in operation. ● The function "Reset to factory defaults" is enabled for the RESET button. Note Reset despite disabled "RESET" button If you have disabled the "Reset to Factory Defaults"function for the "RESET" button in the configuration, this does not apply during the startup phase, see section "Restoring the factory settings (Page 48)"...
Description of the device 3.5 Combo ports Combo ports Characteristics Combo port is the name for two communication ports. A combo port has the two following jacks: ● a fixed RJ-45 port ● an SFP transceiver slot that can be equipped individually Of these two ports, only one can ever be active.
Page 26
Description of the device 3.5 Combo ports SCALANCE XR-300WG Operating Instructions, 05/2017, C79000-G8976-C454-01...
Installation Safety notices for installation Safety notices When installing the device, keep to the safety notices listed below. WARNING If a device is operated in an ambient temperature of more than 40 °C, the temperature of the device housing may be higher than 70 °C. The device must therefore be installed so that it is only accessible to service personnel or users that are aware of the reason for restricted access and the required safety measures at an ambient temperature higher than 40 ℃.
Page 28
Installation 4.1 Safety notices for installation WARNING When used in hazardous environments corresponding to Class I, Division 2 or Class I, Zone 2, the device must be installed in a cabinet or a suitable enclosure. Safety notices for use according to ATEX and IECEx If you use the device under ATEX or IECEx conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion: WARNING...
Page 29
Installation 4.1 Safety notices for installation WARNING Explosion hazard Do not disconnect equipment when a flammable or combustible atmosphere is present. WARNING EXPLOSION HAZARD For operation the device is intended to be installed within an enclosure/control cabinet. The inner temperature of the enclosure/control cabinet corresponds to the ambient temperature of the device.
Page 30
Installation 4.1 Safety notices for installation Further notes CAUTION Use only approved components If you use components and accessories that are not approved for SIMATIC NET devices or their target systems, this may violate the requirements and regulations for safety and electromagnetic compatibility.
Installation 4.2 19" rack mounting 19" rack mounting Mounting CAUTION Risk of injury if subjected to irregular mechanical strain The device must be mounted in the 19" rack so that even if there is irregular mechanical strain, no dangerous situation can result. Figure 4-1 19"...
Page 32
Installation 4.2 19" rack mounting NOTICE Rack-mount instructions A) Elevated Operating Ambient - If installed in a closed or multi-unit rack, the operating ambient temperature of the rack environment may be greater than the room ambient. Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
WARNING Use only approved SFP transceivers If you use SFP transceivers that have not been approved by Siemens AG, there is no guarantee that the device will function according to its specifications. If you use unapproved SFP transceivers, this can lead to the following problems: •...
Installation 4.3 Inserting and removing pluggable transceivers 4.3.3 Removing a pluggable transceiver (SFP) Notes on deinstallation CAUTION Risk of burns due to the high temperatures of the pluggable transceiver The pluggable transceivers can be plugged and pulled during operation. Leave the transceiver to cool down as much as possible.
Connecting up Safety when connecting up Safety notices When connecting up the device, keep to the safety notices listed below. If using power sources according to NEC Class 2 or LPS, please note the following information: WARNING The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited Power Source (LPS).
Page 36
Connecting up 5.1 Safety when connecting up Safety notices on use in hazardous areas General safety notices relating to protection against explosion WARNING EXPLOSION HAZARD Do not connect or disconnect cables to or from the device when a flammable or combustible atmosphere is present.
Connecting up 5.2 Industrial Ethernet Industrial Ethernet 5.2.1 Electrical Note Strain relief of the interfaces To prevent weights or mechanical movement that can affect an interface causing interrupted contact, fix the cables to a cable guide or rail at short intervals. R-45 connector technology The attachment to Industrial Ethernet uses RJ-45 connected technology with MDI-X assignment.
Page 38
Connecting up 5.2 Industrial Ethernet MDI / MDI-X autocrossover With the MPI/MDI-X autocrossover function, the send and receive contacts of an Ethernet port are assigned automatically. The assignment depends on the cable with which the communications partner is connected. This means that it does not matter whether the port is connected using a patch cable or crossover cable.
Connecting up 5.2 Industrial Ethernet 5.2.2 Optical NOTICE Failure of the data traffic due to contamination of optical plug-in connections Optical sockets and plugs are sensitive to contamination of the end face. Contamination can lead to the failure of the optical transmission network. Close unused optical sockets and plugs as well as pluggable transceivers and slots with the supplied protective caps.
Connecting up 5.3 Wiring rules Wiring rules When wiring, use cables with the following AWG* categories or cross sections. Wiring rules for ... Spring-loaded terminals connectable cable cross without wire end ferrule 0.75 - 2.5 mm sections for flexible cables ... AWG: 20 - 14 with wire end ferrule** 0.75 - 2.5 mm...
Connecting up 5.4 24 VDC power supply 24 VDC power supply Safety extra low voltage WARNING Power supply The device is designed for operation with a directly connectable safety extra-low voltage (SELV). NOTICE Suitable fusing for the power supply cables The current on the terminal may not exceed 5 A.
Page 42
Connecting up 5.4 24 VDC power supply CAUTION Overvoltage protection for the power supply cables If SCALANCE XR-300WGs are supplied over long 24 V power supply lines or networks, measures are necessary to prevent interference by strong electromagnetic pulses on the supply lines.
Connecting up 5.5 Power supply 240 VAC Power supply 240 VAC Notes on the power supply WARNING Danger from line voltage for devices with a 240 VAC power supply This device can only function correctly and safely if it is transported, stored, set up, and installed correctly, and operated and maintained as recommended.
Connecting up 5.6 Serial interface Position Figure 5-2 Position of the device installation connector Serial interface Information on the serial interface ● Via the serial interface (RJ-11 jack), you can access the CLI of the device directly via an RS-232 connection (115200 8N1) without assigning an IP address. ●...
Connecting up 5.7 Functional ground Assignment of the connecting cable The connecting cable listed in the "Accessories" section has the following pin assignment: Contact Pin assignment of the RJ-11 plug Pin assignment of the D-sub female con- nector TD (Transmit Data) TD (Transmit Data) RD (Receive Data) SG (Signal Ground)
Page 46
Connecting up 5.7 Functional ground Connecting up functional ground ① Grounding terminal with cable ② Grounding screw with spring washer and washer To connect the functional ground, use a copper cable of category 20 AWG or a cable with a cross-section ≥...
Upkeep and maintenance Downloading new firmware using TFTP without WBM and CLI Firmware The firmware is signed and encrypted. This ensures that only firmware created by Siemens can be downloaded to the device. Procedure with Microsoft Windows Using TFTP, you can supply a device with new firmware even when it cannot be reached using WBM or CLI.
Upkeep and maintenance 6.2 Restoring the factory settings Restoring the factory settings NOTICE Previous settings If you reset, all the settings you have made will be overwritten by factory defaults. NOTICE Inadvertent reset An inadvertent reset can cause disturbances and failures in the configured network. With the "RESET"...
Technical specifications 7.1 Technical specifications of the SCALANCE XR324WG Technical specifications Weight 2700 g Installation options 19" rack mounting Mean time between failure (MTBF) MTBF (EN/IEC 61709; 40 > 56 years °C) 7.1.2 240 VAC variant The following technical specifications apply to the 240 VAC variant of the SCALANCE XR324WG.
Technical specifications 7.2 Technical specifications of the SCALANCE XR328-4C WG Technical specifications Dimensions (W x H x D) 482.6 x 43.6 x 177 mm Weight 3300 g Installation options 19" rack mounting Mean time between failure (MTBF) MTBF (EN/IEC 61709; 40 >...
Page 52
Technical specifications 7.2 Technical specifications of the SCALANCE XR328-4C WG Technical specifications Fusing 5 A / at least 60 V Or power supply with LPS or NEC class 2 Current consumption 500 mA Effective power loss 12 W Permitted ambient conditions Ambient temperature During operation up to 3000 m 0 ℃...
Technical specifications 7.2 Technical specifications of the SCALANCE XR328-4C WG 7.2.2 240 VAC variant The following technical specifications apply to the 240 VAC variant of the SCALANCE XR328-4C WG. Technical specifications Attachment to Industrial Ethernet Electrical connectors Quantity Connector RJ-45 jack Properties Half/full duplex, MDI-X pinning Transmission speed...
Technical specifications 7.3 Technical specifications of the SCALANCE XR328-4C WG (GE) Technical specifications Weight 3400 g Installation options 19" rack mounting Mean time between failure (MTBF) MTBF (EN/IEC 61709; 40 °C) > 39 years Depending on which pluggable transceiver you use, the maximum ambient temperature can change, see section "Accessories (Page 19)".
Technical specifications 7.3 Technical specifications of the SCALANCE XR328-4C WG (GE) Technical specifications Current consumption 900 mA Effective power loss 21.6 W Permitted ambient conditions Ambient temperature During operation up to 3000 m 0 ℃ to +60 ℃ During storage -40 ℃...
Page 56
Technical specifications 7.3 Technical specifications of the SCALANCE XR328-4C WG (GE) Technical specifications Diagnostics interface Serial interface Quantity Connector RJ-11 jack Electrical data Power supply Design Socket, 3 pin Rated voltage 100 to 240 VAC Voltage range 85 to 264 VAC Frequency 50 Hz to 60 Hz Frequency range...
Technical specifications 7.4 Mechanical stability (in operation) Mechanical stability (in operation) The following technical specifications apply to the following devices: ● SCALANCE XR324WG ● SCALANCE XR328-4C WG IEC 60068-2-27 shock IEC 60068-2-6 vibration 15 g, 11 ms duration 10 - 58 Hz: 0.075 mm 6 shocks per axis 85 - 150 Hz: 1 g 1 octave/min, 20 sweeps...
Page 58
Technical specifications 7.6 Switching properties Switching properties QoS priority queues Switching technique Store and forward Latency 10 microseconds Full wire speed switching Frame length (bytes) Number of frames per second (at 100 Mbps) 148810 84459 45290 23496 1024 11973 1280 9615 1518 8127...
You can check which of the following approvals have been granted for your product by the markings on the type plate. Current approvals on the Internet You will find the current approvals for the product on the Internet pages of Siemens Industry Online Support (http://support.automation.siemens.com/WW/view/en/33118389/134200). EC declaration of conformity...
Page 62
Area". You will find this document • on the data medium that ships with some devices. • on the Internet pages of Siemens Industry Online Support (http://support.automation.siemens.com/WW/view/en). Enter the document identification number C234 as the search term. The SIMATIC NET products meet the requirements of the EC directive 94/9/EC "Equipment and Protective Devices for Use in Potentially Explosive Atmospheres”.
Page 63
Approvals IECEx The SIMATIC NET products meet the requirements of explosion protection according to IECEx. IECEx classification: Ex nA IIC T4 Gc DEK 14.0025X The products meet the requirements of the following standards: ● IEC 60079-15 (Explosive atmospheres - Part 15: Equipment protection by type of protection "n") ●...
Page 64
Approvals The product meets the requirements of the standards: ● Factory Mutual Approval Standard Class Number 3611 ● FM Hazardous (Classified) Location Electrical Equipment: Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and Non Incendive / Class I / Zone 2 / Group IIC / T4 Note Only variants with 24 VDC power supply meet the requirements of this approval.
Page 65
Only variants with 24 VDC power supply meet the requirements of this approval. Safety of electrical equipment In the version put into circulation by Siemens AG, the SIMATIC NET products described in these Operating Instructions conform to the regulations of the following European directive: ●...
Page 66
You will find information on the system manuals in the section "AUTOHOTSPOT", in "Further documentation". ● "EMC Installation Guidelines" configuration manual 60612658 (http://support.automation.siemens.com/WW/view/en/60612658) WARNING Personal injury and property damage can occur The installation of expansions that are not approved for SIMATIC NET products or their target systems may violate the requirements and regulations for safety and electromagnetic compatibility.
Page 67
Approvals Note The test was performed with a device and a connected communications partner that also meets the requirements of the standards listed above. When operating the device with a communications partner that does not comply with these standards, adherence to the corresponding values cannot be guaranteed. SCALANCE XR-300WG Operating Instructions, 05/2017, C79000-G8976-C454-01...