Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Unless mentioned otherwise, the descriptions in these operating instructions refer to all devices of the SCALANCE XB-200 product group named above in the section on validity. There are two variants of each device, refer to the section "Product overview (Page 11)".
Page 4
● On the data medium that ships with some products: – Product CD / product DVD – SIMATIC NET Manual Collection ● On the Internet pages of Siemens Industry Online Support under the following entry IDs: – 27069465 (http://support.automation.siemens.com/WW/view/en/27069465) Industrial Ethernet / PROFINET Industrial Ethernet System Manual –...
Page 5
● On the Internet under the following address: 50305045 (http://support.automation.siemens.com/WW/view/en/50305045) Catalogs You will find the order numbers for the Siemens products of relevance here in the following catalogs: ● SIMATIC NET Industrial Communication / Industrial Identification, catalog IK PI ● SIMATIC Products for Totally Integrated Automation and Micro Automation, catalog ST 70 ●...
Page 6
Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept.
This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non- hazardous locations only. This equipment is suitable for use in Class I, Zone 2, Group IIC or non-hazardous locations only. SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
Page 12
● Base bridge mode: 802.1D transparent bridge ● Redundancy mechanism: Ring redundancy ● Trust mode: Trust COS Type designation The type designation of a SCALANCE XB-200 is made up of several parts that have the following meaning: Interfaces of devices with optical connectors: Interface...
The following figure shows an overview of the components of the SCALANCE XB208. ① Electrical ports with port LEDs ② Power supply with connector for grounding ③ Serial interface ④ "RESET" button (rear) ⑤ Fault LED SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
The following figure shows an overview of the components of the SCALANCE XB205-3. ① Optical ports with port LEDs ② Power supply with connector for grounding ③ Serial interface ④ Electrical ports with port LEDs ⑤ "RESET" button (rear) ⑥ Fault LED SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
The following figure shows an overview of the components of the SCALANCE XB213-3. ① Optical ports with port LEDs ② Power supply with connector for grounding ③ Serial interface ④ Electrical ports with port LEDs ⑤ "RESET" button (rear) ⑥ Fault LED SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
Description of the device 2.3 RESET button RESET button Position The "RESET" button is located on the rear of the SCALANCE XB-200. Figure 2-1 Position of the "RESET" button, for example on the SCALANCE XB213-3 Resetting the device to factory defaults...
Page 17
Using the WBM and CLI, you can enable or disable the button function. You will find detailed information about configuration of the button in the Configuration manuals (Page 3): ● SCALANCE XB-200 Web Based Management, section "Button" ● SCALANCE XB-200 Command Line Interface, section "Panel-Button" SCALANCE XB-200...
Receiving data at port Not receiving data at port SC/ST ports There is an LED for each SC/ST port. LED color LED status Meaning Green Link exists, data reception at port No link exists SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
The device may only be operated in an environment with pollution degree 1 or 2 (see IEC 60664-1). WARNING When used in hazardous environments corresponding to Class I, Division 2 or Class I, Zone 2, the device must be installed in a cabinet or a suitable enclosure. SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
Page 20
"Industrial Ethernet / PROFINET Industrial Ethernet" and "Industrial Ethernet / PROFINET passive network components". You will find information on the system manuals in the section "Introduction (Page 3)", in "Further documentation". SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
2. Press the device down against the DIN rail until the spring catch locks in place 3. Fit the connectors for the power supply, see the section "Power supply (Page 25)". 4. Insert the terminal blocks into the sockets on the device. SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
Page 22
1. Disconnect all connected cables. ① 2. Release the DIN rail locking mechanism by pressing down on the release button ② 3. Pull the lower part of the device away from the DIN rail SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
Remove the protective caps only immediately before you use the plug-in connection. Safety notices on use in hazardous areas General safety notices relating to protection against explosion WARNING EXPLOSION HAZARD DO NOT CONNECT OR DISCONNECT EQUIPMENT WHEN A FLAMMABLE OR COMBUSTIBLE ATMOSPHERE IS PRESENT. SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
Page 24
The LAN is designed either for “Environment A” according to IEEE802.3 or "Environment 0" according to IEC TR 62102. Do not connect any electrical connectors directly to the telephone network (telephone network voltage) or a WAN (Wide Area Network). SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
Manufacturer: DEHN+SOEHNE GmbH+Co.KG, Hans-Dehn-Str.1, Postfach 1640, D92306 Neumarkt, Germany Operate the SCALANCE XB-200 with suitable overvoltage protection. Information on the power supply ● The power supply is connected using a 3-pin plug-in terminal block (spring-loaded terminal).
Page 26
Connecting up 4.2 Power supply Position and assignment Figure 4-1 Position of the power supply, for example on the SCALANCE XB213-3 Contact Assignment Assignment Contact 24 VDC 24 VDC Ground Ground Functional ground Functional ground SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
With automation components, functional ground also ensures interference-free operation of a controller. Via the functional ground, interference currents coupled in via the connecting cables are discharged to ground. SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
Upkeep and maintenance Downloading new firmware using TFTP without WBM and CLI Firmware The firmware is signed and encrypted. This ensures that only firmware created by Siemens can be downloaded to the device. Pressing the "RESET" button To load new firmware, you require the "RESET" button. When pressing the button, remember the information in the section "RESET button (Page 16)".
Page 30
"Control Panel" > "Programs and Features" > "Turn Windows features on or off" > "TFTP Client". 8. Once the firmware has been transferred completely to the device and validated, there is an automatic restart on the device. This may take several minutes. SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
You will find detailed information on resetting the device parameters using the WBM and CLI in the configuration manuals (Page 3): ● SCALANCE XB-200 Web Based Management, section "Restart" ● SCALANCE XB-200 Command Line Interface, section "Reset and Defaults" SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
Page 32
Upkeep and maintenance 5.2 Restoring the factory settings SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
Housing, dimensions and weight Design compact Housing material Polycarbonate (PC-GF10) Degree of protection IP20 Dimensions (W x H x D) 40 x 117 x 109 mm Weight 250 g Installation options Installation on a DIN rail SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
Page 34
Technical specifications 6.1 Technical specifications of the SCALANCE XB208 Technical specifications Mean time between failure (MTBF) MTBF (EN/IEC 61709; 40 °C) > 84 years SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
• • Maximum 1.5 mm (16 AWG) • • Properties Implemented redundantly Current consumption at 24 VDC 300 mA Effective power loss at 24 VDC 7.2 W Fusing F 2.5 A / 125 V SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
Page 36
Mean time between failure (MTBF) MTBF (EN/IEC 61709; 40 °C) > 55 years For every optical port that you set to "link down", the current consumtion of the device is reduced by 30 mA. SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
(24 AWG) • • Maximum 1.5 mm (16 AWG) • • Properties Implemented redundantly Current consumption at 24 VDC 290 mA Effective power loss at 24 VDC Fusing F 2.5 A / 125 V SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
Page 38
Mean time between failure (MTBF) MTBF (EN/IEC 61709; 40 °C) > 50 years For every optical port that you set to "link down", the current consumtion of the device is reduced by 30 mA. SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
• • Maximum 1.5 mm (16 AWG) • • Properties Implemented redundantly Current consumption at 24 VDC 300 mA Effective power loss at 24 VDC 7.2 W Fusing F 2.5 A / 125 V SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
Page 40
Mean time between failure (MTBF) MTBF (EN/IEC 61709; 40 °C) > 55 years For every optical port that you set to "link down", the current consumtion of the device is reduced by 30 mA. SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
Dimensions (W x H x D) 80 x 117 x 109 mm Weight 400 g Installation options Installation on a DIN rail Mean time between failure (MTBF) MTBF (EN/IEC 61709; 40 °C) > 60 years SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
• • Maximum 1.5 mm (16 AWG) • • Properties Implemented redundantly Current consumption at 24 VDC 410 mA Effective power loss at 24 VDC 9.8 W Fusing F 2.5 A / 125 V SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
Page 43
Mean time between failure (MTBF) MTBF (EN/IEC 61709; 40 °C) > 45 years For every optical port that you set to "link down", the current consumtion of the device is reduced by 30 mA. SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
• • Maximum 1.5 mm (16 AWG) • • Properties Implemented redundantly Current consumption at 24 VDC 400 mA Effective power loss at 24 VDC 9.6 W Fusing F 2.5 A / 125 V SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
Page 45
Mean time between failure (MTBF) MTBF (EN/IEC 61709; 40 °C) > 40 years For every optical port that you set to "link down", the current consumtion of the device is reduced by 30 mA. SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
• • Maximum 1.5 mm (16 AWG) • • Properties Implemented redundantly Current consumption at 24 VDC 410 mA Effective power loss at 24 VDC 9.8 W Fusing F 2.5 A / 125 V SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
Page 47
Mean time between failure (MTBF) MTBF (EN/IEC 61709; 40 °C) > 45 years For every optical port that you set to "link down", the current consumtion of the device is reduced by 30 mA. SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
0 to 90 m with IE FC Outlet RJ-45 + 10 m TP cord + 10 m TP cord IE FC TP standard cable 0 to 100 m with IE FC RJ-45 Plug 180 SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
1518 bytes Note The number of SCALANCE XB-200 modules connected in a line influences the frame delay. When a frame passes through the switch, this is delayed by the store-and-forward function of the SCALANCE XB-200 by 10-130 microseconds (at 100 Mbps).
Dimension drawings Note Dimensions are specified in mm. Front view of the SCALANCE XB208 Figure 7-1 Width and height SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
Page 52
Dimension drawings Front view of the SCALANCE XB205-3 (SC), XB205-3LD (SC), XB205-3 and XB216 Figure 7-2 Width and height based on the example of the SCALANCE XB205-3 SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
Page 53
Dimension drawings Front view of the SCALANCE XB213-3 (SC), XB213-3LD (SC) and XB213-3 Figure 7-3 Width and height based on the example of the SCALANCE XB213-3 SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
Page 54
Dimension drawings Side view of the SCALANCE XB-200 Figure 7-4 Depth SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...
Page 55
You can check which of the following approvals have been granted for your product by the markings on the type plate. Current approvals on the Internet You will find the current approvals for the product on the Internet pages of Siemens Industry Online Support (http://support.automation.siemens.com/WW/view/en/33118389/134200). → Entry type "Certificates"...
Page 56
Safety of electrical equipment In the version put into circulation by Siemens AG, the SIMATIC NET products described in these Operating Instructions conform to the regulations of the following European directive: ●...
Page 57
Area". You will find this document • on the data medium that ships with some devices. • on the Internet pages of Siemens Industry Online Support (http://support.automation.siemens.com/WW/view/en). Enter the document identification number C234 as the search term. SIMATIC NET products meet the requirements of the EC directive:94/9/EC "Equipment and Protective Devices for Use in Potentially Explosive Atmospheres".
Page 58
The products meet the requirements of the "Korean Standard". Marking for the customs union EAC (Eurasian Conformity) Customs union of Russia, Belarus and Kazakhstan Declaration of the conformity according to the technical regulations of the customs union (TR CU) SCALANCE XB-200 Operating Instructions, 09/2015, C79000-G8976-C359-03...