Cutting Deck Blade Braking

When the operator turns the PTO switch OFF (or if the
decks are raised), deck manifold solenoid valves
(PRV1, PRV2, SV1 and SV2) are de--energized. The
valves will shift to direct oil away from the deck motors
and toward the oil cooler and filter. Hydraulic pressure
is reduced to the cutting deck motors which slows the
cutting blades and also allows the deck manifold relief
valve (RV) to shift. The shifted relief valve removes the
flow path from the orifice at the logic cartridge, causing
the logic cartridge to shift and block the return oil path
from the deck motors (Fig. 20).
The inertia of the rotating cutting blades, however, effec-
tively turns the deck motors into pumps causing an in-
crease in pressure as the flow from the motors comes
up against the closed logic cartridge (LC). When this
pressure builds to approximately 1500 PSI (104 bar),
the relief valve opens which allows a small amount of hy-
draulic flow past the relief valve (Fig. 21). This flow
causes a pressure increase that shifts the logic cartridge
to once again allow oil flow from the deck motors (Fig.
22). When return pressure drops below 1500 PSI (104
bar), the relief valve reseats and causes the logic car-
tridge to close again, blocking return flow from the deck
motors to further slow the cutting blades. This action of
the relief valve opening and the logic cartridge shifting
occurs several times in a very short time frame as the
blades finally come to a stop. Once the blades have
stopped, the logic cartridge remains in the neutral posi-
tion to keep the deck motors from rotating.
Hydraulic System
#1
1.16
CID
FRONT
CENTER
#4
1.16
CID
FRONT
LEFT
ORIFICE
#1
1.16
CID
FRONT
CENTER
#4
1.16
CID
FRONT
LEFT
ORIFICE
#1
1.16
FRONT
CID
CENTER
#4
1.16
CID
FRONT
LEFT
ORIFICE
Page 4 - - 26
DECK CONTROL
MANIFOLD
M3
1500
PSI
PRV2
3500
PSI
RV09
M4
LC2
G4
TO OIL
COOLER
Figure 20
DECK CONTROL
MANIFOLD
M3
1500
PSI
PRV2
3500
PSI
RV09
M4
LC2
G4
TO OIL
COOLER
Figure 21
DECK CONTROL
MANIFOLD
M3
1500
PSI
3500
PRV2
PSI
RV09
M4
LC2
G4
TO OIL
COOLER
Figure 22
Groundsmaster 4500--D/4700--D
G3
P2
FROM
GEAR
PUMP
G3
P2
FROM
GEAR
PUMP
G3
P2
FROM
GEAR
PUMP