Adjustments
Adjust Control Manifold Relief Valves
Several of the hydraulic control manifolds on your
Groundsmaster include adjustable relief valves. The fol-
lowing procedure can be used to adjust these relief
valves. Refer to the Testing section of this chapter for in-
formation on testing relief pressure.
NOTE: Do not remove relief valve from the hydraulic
manifold for adjustment.
1
1. Locate relief valve on control manifold.
2. Remove cap on relief valve with an allen wrench.
3. To increase pressure setting, turn the adjustment
socket on the valve in a clockwise direction. A 1/8 turn
on the socket will make a measurable change in relief
pressure.
2
4. To decrease pressure setting, turn the adjustment
socket on the valve in a counterclockwise direction. A
1/8 turn on the socket will make a measurable change
in relief pressure.
5. Install and tighten cap on relief valve.
Figure 60
1. Relief valve cap
2.
Adjustment socket
6. Recheck relief pressure and readjust as needed.
Hydraulic System
Page 4 - - 72
Groundsmaster 4500--D/4700--D