hit counter script

Fan Control Manifold Service - Toro Groundsmaster 4500-D Service Manual

Hide thumbs Also See for Groundsmaster 4500-D:
Table of Contents

Advertisement

Fan Control Manifold Service

50 ft- -lb
(68 N- -m)
5
25 ft- -lb
1
(34 N- -m)
2
3
20 ft- -lb
(27 N- -m)
1. Manifold body
2. Zero leak plug (#6) (3 used)
3. Zero leak plug (#4) (2 used)
4. Check valve (port CV)
NOTE: The ports on the fan control manifold are
marked for easy identification of components (e.g. ST is
the supply to the steering control valve and FD is the
location of the flow divider cartridge valve). See Hydrau-
lic Schematics in Chapter 9 -- Foldout Drawings to identi-
fy the function of the hydraulic lines and cartridge valves
at each port location.
For solenoid and control valve service procedures, see
Control Manifold Cartridge Valve Service in this section.
Refer to Figure 109 for cartridge valve and plug installa-
tion torque.
Hydraulic System
2
25 ft- -lb
(34 N- -m)
UP
4
20 ft- -lb
(27 N- -m)
5. Flow divider cartridge (port FD)
6. Solenoid coil (2 used)
7. Nut
5 ft- -lb
(6.8 N- -m)
10
6
9
2
25 ft- -lb
(34 N- -m)
1
Figure 109
NOTE: The fan control manifold includes several zero
leak plugs. These plugs have a tapered sealing surface
on the plug head that is designed to resist vibration in-
duced plug loosening. The zero leak plugs also have an
O--ring as a secondary seal. If zero leak plug removal is
necessary, lightly rap the plug head using a punch and
hammer before using an allen wrench to remove the
plug: the impact will allow plug removal with less chance
of damage to the socket head of the plug.
Page 4 - - 130
5 ft- -lb
(6.8 N- -m)
7
8
25 ft- -lb
(34 N- -m)
8. Solenoid valve (port S1)
9. Proportional relief cartridge (port TS)
10. Nut
Groundsmaster 4500--D/4700--D
6
UP

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

30882Groundsmaster 4700-d308733088130874

Table of Contents

Save PDF