hit counter script

How To Shut Down The Sce Platform; Examples For Shutting Down The Sce Platform - Cisco SCE8000 Installation And Configuration Manual

Cisco systems router installation and configuration guide
Hide thumbs Also See for SCE8000:
Table of Contents

Advertisement

Chapter 7
Basic Cisco SCE8000 Platform Operations

How to Shut Down the SCE Platform

Shutting down the SCE platform is required before turning the power off. This helps to ensure that
non-volatile memory devices in the SCE platform are properly flushed in an orderly manner.
Note
When the SCE platform restarts, it loads the startup configuration, so all changes made in the running
configuration will be lost. You are advised to save the running configuration before performing reload,
as described in
Connect to the serial console port (The CON connector on the front panel of the Service Control module
Step 1
in slot #1, 9600 baud).
The SCE# prompt appears.
Type reload shutdown.
Step 2
A confirmation message appears.
Step 3
Type y to confirm the shutdown request and press Enter.

Examples for Shutting Down the SCE Platform

The following example shows the commands for system shutdown.
SCE#reload shutdown
You are about to shut down the system.
The only way to resume system operation after this
is to cycle the power off, and then back on.
Continue?
y
IT IS NOW SAFE TO TURN THE POWER OFF.
Since the SCE platform can recover from the power-down state only by being physically turned off (or
Note
cycling the power), this command can only be executed from the serial CLI console. This limitation
helps prevent situations in which a user issues this command from a Telnet session, and then realizes he
or she has no physical access to the SCE platform.
OL-16478-03
Saving or Changing the Configuration Settings, page
Rebooting and Shutting Down the SCE Platform
Cisco SCE8000 Installation and Configuration Guide, Rel 3.1.7
7-6.
7-17

Advertisement

Table of Contents
loading

Table of Contents

Save PDF