hit counter script

Ntp- D286 Install The Fc_Mr-4 Cards - Cisco ONS 15454 SDH Procedure Manual

Hide thumbs Also See for ONS 15454 SDH:
Table of Contents

Advertisement

Chapter 2
Install Cards and Fiber-Optic Cable
Class I (21 CFR 1040.10 and 1040.11) and Class 1M (IEC 60825-1 2001-01) laser products. Statement 291
Warning
Invisible laser radiation may be emitted from the end of the unterminated fiber cable or connector. Do
Warning
not view directly with optical instruments. Viewing the laser output with certain optical instruments
(for example, eye loupes, magnifiers, and microscopes) within a distance of 100 mm may pose an eye
hazard. Statement 1056
Always use the supplied ESD wristband when working with a powered ONS 15454 SDH. Plug the
Caution
wristband cable into the ESD jack located on the lower-right outside edge of the shelf assembly.
Note
If protective clips are installed on the backplane connectors of the cards, remove the clips before
installing the cards.
Warning
High-performance devices on this card can get hot during operation. To remove the card, hold it by
the faceplate and bottom edge. Allow the card to cool before touching any other part of it or before
placing it in an antistatic bag. Statement 201
If you installed XC-VXL-2.5G cards, review
Step 1
If you installed XC-VXL-10G or XC-VXC-10G cards, review
card/slot compatibility.
Open the card latches/ejectors.
Step 2
Use the latches/ejectors to firmly slide the card along the guide rails until the card plugs into the
Step 3
receptacle at the back of the slot.
Verify that the card is inserted correctly and close the latches/ejectors on the card.
Step 4
Note
Note
Verify the LED activity:
Step 5
The red FAIL LED turns on for 20 to 30 seconds. The ACT LED is amber for 3 to 5 seconds.
The red FAIL LED blinks for up to 2 minutes.
The FAIL and ACT LEDs blink once and turn off for 1 to 5 seconds.
The ACT LED illuminates green.
Note
78-17194-01
It is possible to close the latches/ejectors when the card is not completely plugged into the
backplane. Ensure that you cannot insert the card any further.
If you install the wrong card in a slot, complete the
procedure on page 2-20
and install the correct card.
If the red FAIL LED does not turn on, check the power.

NTP- D286 Install the FC_MR-4 Cards

Table 2-1 on page 2-3
to determine card/slot compatibility.
Table 2-2 on page 2-5
"NTP-D227 Remove and Replace a Card"
Cisco ONS 15454 SDH Procedure Guide, R7.0
to determine
2-13

Advertisement

Table of Contents
loading

Table of Contents