NTP-D192 Create a Circuit for an E-Series Card in Port-Mapped
Mode
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Complete the
Step 1
where you will create the circuit. If you are already logged in, continue with
If you want to assign a name to the circuit source and destination ports before you create the circuit,
Step 2
complete the
automatically based on circuit type, node name, and sequence number, continue with
Step 3
Complete the
Provision and enable the Ethernet ports. See
Step 4
page
Step 5
From the View menu, choose Go to Network View.
Step 6
Click the Circuits tab and click Create.
In the Circuit Creation dialog box, complete the following fields:
Step 7
Click Next.
Step 8
Define the circuit attributes:
Step 9
78-17194-01
This procedure creates an E-Series point-to-point SDH circuit with an
E-Series card in port-mapped mode.
An E-Series Ethernet card must be installed at each end of the circuit and
configured in port-mapped mode.
NTP-D127 Verify Network Turn-Up, page 6-5
As needed
Onsite or remote
Provisioning or higher
"DLP-D60 Log into CTC" task on page 17-49
"DLP-D314 Assign a Name to a Port" task on page
"DLP-D246 Provision E-Series Ethernet Card Mode" task on page
19-18.
Circuit Type—Choose VC_HO_PATH_CIRCUIT.
Number of Circuits—Leave the default (1) unchanged.
Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters
(including spaces). Circuit names should be 44 characters or less if you want the ability to create
monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.
Size—Choose the circuit size. Valid circuit sizes for an E-Series in port-mapped mode are VC4,
VC4-2c, and VC4-4c.
Bidirectional—Leave the default (checked) unchanged.
Create cross-connects only (TL1-like)—Check this check box if you want to create one or more
cross-connects to complete a signal path for TL1-generated circuits. If you check this box, low-order
tunnels and Ethergroup sources and destinations are unavailable.

NTP- D192 Create a Circuit for an E-Series Card in Port-Mapped Mode

at an ONS 15454 SDH on the network
20-7. If you want CTC to assign a name
"DLP-D220 Provision E-Series Ethernet Ports" task on
Cisco ONS 15454 SDH Procedure Guide, R7.0
Step
2.
Step
3.
19-50.
6-75