11-2. Upper thread breakage detector assembly ...... (S40520-009)
q
w
Attachment
1. Remove the screw q, and then remove the upper cover w.
2. Remove the upper cover cap e, and then install the thread breakage detector r to the upper cover w with
the screw t and nut y.
3. Install the upper cover w with the screw q.
4. Bind the cord u of the thread breakage detector r with the band in the same way as the other cords, and
pass it inside the control box.
5. Insert the connector i into the 16-pin connector o on the main circuit board.
When using the upper thread breakage detector assembly
Set panel DIP switch No. 1-1 to ON and then turn on the power.
When not using the upper thread breakage detector assembly
Set panel DIP switch No. 1-1 to OFF and then turn on the power.
NOTE: Refer to "8. Using the DIP switches" on page 66 for details of the panel DIP switches.
r
e
t
y
u
83
11. OPTIONS
i
o
BAS-705