9. ERROR CODES

NOTE : Wait 10 seconds or more after turning the power off before turning it back on again.
Error code
EMERGENCY STOP switch select-
E-100
ed during automatic sewing.
START switch on when power turned
E-101
on.
MERGENCY STOP switch on
E-102
when power turned on.
The second bar tacking lower shaft
E-104
module was open when the power
was turned on.
The cover of the second bar
E-105
tacking lower shaft module.
The second bar tacking lower shaft
E-106
unit is open or the air pressure is
insufficient.
E-107
Abnormal power supply voltage.
E-110
Malfunction of loop feed 1 sensor
E-111
Malfunction of loop feed 2 sensor
E-112
Malfunction of loop feed 3 sensor
E-113
Malfunction of loop feed 4 sensor
E-118
Malfunction of loop down sensor
E-120
Loop feeder retracted
E-150
Two joints were detected in succession.
Problem
71
Solution
Refer to pages 31.
q Turn off START switch.
w Press the RESET switch.
q Turn off EMERGENCY STOP switch.
w Press the RESET switch.
q Turn off the power.
w Release the air, close the second bar tacking lower
shaft module, and then press the RESET switch.
q Close the cover of the second bar tacking lower
shaft module.
w Press the RESET switch.
q Check the air pressure.
w Press the RESET switch.
q Turn off power switch.
w Check the power supply voltage.
q Check the operation of loop feed 1 sensor.
w Press the RESET switch.
q Check the operation of loop feed 2 sensor.
w Press the RESET switch.
q Check the operation of loop feed 3 sensor.
w Press the RESET switch.
q Check the operation of loop feed 4 sensor.
w Press the RESET switch.
q Check the operation of the loop down sensor.
w Press the RESET switch.
q Check that the loop feeder is not retracted.
w Check if the loop feeder retract position sensor is illuminated.
e Press the RESET switch.
q Check the condition of the belt loops.
w Press the RESET switch.