Preventing Electrostatic Discharge Damage

Electrostatic discharge (ESD) damage, which can occur when electronic cards or components are
improperly handled, results in complete or intermittent failures. Port adapters and blades consist of
printed circuit boards that are fixed in metal carriers. Electromagnetic interference (EMI) shielding and
connectors are integral components of the carrier. Although the metal carrier helps to protect the board
from ESD, use a preventive antistatic strap during handling.
Following are guidelines for preventing ESD damage:
Caution
For safety, periodically check the resistance value of the antistatic strap. The measurement should be
between 1 and 10 megohm (Mohm).

Environmental Requirements

Ensure adequate spacing between racks using the information in the following table. Keep all of the
vents clear of obstructions, including dust and foreign conductive material, and away from the exhaust
ports of other equipment.
Table 4-1
Airflow Intake
Right side
OL-16478-03
Always use an ESD wrist or ankle strap and ensure that it makes good skin contact.
Connect the equipment end of the strap to an unfinished chassis surface.
When installing a component, use any available ejector levers or captive installation screws to
properly seat the bus connectors in the backplane or midplane. These devices prevent accidental
removal, provide proper grounding for the system, and help to ensure that bus connectors are
properly seated.
When removing a component, use any available ejector levers or captive installation screws to
release the bus connectors from the backplane or midplane.
Handle carriers by available handles or edges only; avoid touching the printed circuit boards or
connectors.
Place a removed component board-side-up on an antistatic surface or in a static shielding container.
If you plan to return the component to the factory, immediately place it in a static shielding
container.
Avoid contact between the printed circuit boards and clothing. The wrist strap only protects
components from ESD voltages on the body; ESD voltages on clothing can still cause damage.
Never attempt to remove the printed circuit board from the metal carrier.
Chassis Airflow Requirements
Airflow Exhaust
Left side
Minimum
Air Filter Option
Clearance (walls)
Not applicable
6 in (15 cm)
Cisco SCE8000 Installation and Configuration Guide, Rel 3.1.7
Preparing for Installation
Minimum
Horizontal
Separation
12 in (30.5)