Group A6: Ai Curve Setting - Pioneer PE6000 Series User Manual

Table of Contents

Advertisement

Description of Function Codes
It is used to set the overvoltage threshold of the AC drive. The default values of different
voltage classes are listed in the following table.
NOTE: The default value is also the upper limit of the AC drive's internal overvoltage protection
voltage. The parameter becomes effective only when the setting of A5-09 is lower than the default
value. If the setting is higher than the default value, use the default value.

Group A6: AI Curve Setting

A6-00
Corresponding setting of AI curve 4
A6-01
A6-02
Corresponding setting of AI curve 4
A6-03
A6-04
Corresponding setting of AI curve 4
A6-05
Voltage Class
Single-phase 220 V
Three-phase 220 V
Three-phase 380 V
Three-phase 480 V
Three-phase 690 V
Three-phase 1140 V
AI curve 4 minimum input
Setting Range
minimum input
Setting Range
AI curve 4 inflexion 1 input
Setting Range
inflexion 1 input
Setting Range
AI curve 4 inflexion 1 input
Setting Range
inflexion 1 input
Setting Range
Default Overvoltage Threshold
400.0 V
400.0 V
810.0 V
890.0 V
1300.0 V
2000.0V
Default
Default
Default
Default
Default
Default
172
PE6000 User Manual
0.00 V
-10.00 V to A6-02
0.00 V
-100.0%–100.0%
3.00 V
A6-00 to A6-04
30.00 V
-100.0%–100.0%
6.00 V
A6-02 to A6-06
60.0%
-100.0%–100.0%