hit counter script

Group Pd Communication Parameters; Group Pp: User Password - Pioneer PE6000 Series User Manual

Table of Contents

Advertisement

Description of Function Codes
Function
Parameter Name
Code
PC-51
Reference 0 source
It determines the setting channel of reference 0. You can perform convenient switchover
between the setting channels. When multi-reference or simple PLC is used as frequency source,
the switchover between two frequency sources can be realized easily.

Group PD Communication Parameters

Please refer to the PE6000 Communication Agreement.

Group PP: User Password

User password
PP-00
Setting Range
If it is set to any non-zero number, the password protection function is enabled. After a
password has been set and taken effect, you must enter the correct password in order to enter the
menu. If the entered password is incorrect you cannot view or modify parameters.
If PP-00 is set to 00000, the previously set user password is cleared, and the password
protection function is disabled.
Parameter Name
PP-01
Setting Range
1. Restore default settings except motor parameters
If PP-01 is set to 1, most function codes are restored to the default settings except motor
parameters, frequency reference resolution (P0-22), fault records, accumulative running time
(P7-09), accumulative power-on time (P7-13) and accumulative power consumption (P7-14).
Setting Range
0: Set by PC-00 1: AI1
2: AI2
3: potentiometer
4: Pulse setting
5: PID
6: Set by preset frequency (P0-08),
modified via terminal UP/DOWN
Default
Restore default settings
0: No operation
1: Restore factory settings except motor parameters
2: Clear records
4: Restore user backup parameters
501: Back up current user parameters
164
PE6000 User Manual
0
0–65535
Default
0
0

Advertisement

Table of Contents
loading

Table of Contents

Save PDF