hit counter script

Rebuilding Failed Drives - Asus RS720Q-E8-RS12 User Manual

2u rackmount server
Table of Contents

Advertisement

6.2.4

Rebuilding failed drives

You can manually rebuild failed hard disk drives using the Rebuild command in the
Management Menu.
To rebuild a failed hard disk drive
1.
From the Management Menu, select Rebuild, and then press <Enter>.
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
2.
The PHYSICAL DRIVES SELECTION MENU displays the available drives connected
to the SATA ports. Select the drive you want to rebuild, and then press <Space>.
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
SPACE-(De)Select,F10-Start Rebuild,F2-Drive Information,F3-View Virtual Drives
6-16
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version
REBUILD - PHYSICAL DRIVES SELECTION MENU
0
1
Port # 1 DISK
77247MB
A.10.09231523R
Rebuild VD(s)
A.10.09231523R
PORT #
ONLIN A00-00
FAIL A00-01
HDS72808PLA380
PF20A60A
Chapter 6: RAID configuration

Advertisement

Table of Contents
loading

Table of Contents