Special Installation (Place product upright and flush, embedded in the wall)
3.4.7 Place product upright and flush into wall (embedding in the wall)
Carefully read the following instructions before trying to embed the unit in a wall. Observe all the limitations specified
below.
Be sure to mount the unit so that twisting, bending, or other deformation of the unit does not exceed 4 mm.
(1) Embedding in walls with space provided behind the unit (with no obstructions within a distance of 300 mm
from the back surface of the unit)
A
A
<Viewed from the Right Side>
✩ Operating Temperature Restrictions
A: 0 mm to 370 mm
*1
For this installation, set the 'FAN CONTROL' to 'MAX' as shown in "5.4.3 Adjustment and Setting in the Integrator Mode 14)
Cooling Fan Control Setting" (pg. 172).
*2
When INPUT2 has been selected, use input compatible signal up to 1280x1024 (60 Hz) at ambient temperature condition of
0 °C to 35 °C.
38
A
<Viewed from Above>
(*1, *2)
Temperature in space X and Y
0 °C to 40 °C
X (Front of the unit)
Y (Rear of the unit)
A