7 Other commands
Command
DISPLAY CALL
DITS01
Displays DISPLAY CALL 1.
DITS02
Displays DISPLAY CALL 2.
IM0
INFORMATION write-in (1-3 characters).
IM1
INFORMATION write-in (4-6 characters).
IM2
INFORMATION write-in (7-9 characters).
IM3
INFORMATION write-in (10-12 characters).
IM4
INFORMATION write-in (13-15 characters).
IM5
INFORMATION write-in (16-18 characters).
IM6
INFORMATION write-in (19-21 characters).
IMD
Clears INFORMATION.
AUXILIARY COMMAND
DW0
Subtracts 10 from the adjustment value.
DWF
Minimizes the adjustment value.
DWn
Subtracts n from the adjustment value. (n=1~9)
UP0
Adds 10 to the adjustment value.
UPF
Maximizes the adjustment value.
UPn
Adds n to the adjustment value (n = 1 to 9).
5.5.6 QUEST Commands
What are QUEST commands?
• Quest commands output TXD such as adjustment data from the panel's microprocessor to a PC.
• Adjustment and other data is output in ASCII code.
Note
Command names are given inside brackets < >.
• Data output format
Command
STX (02hex)
(3 Byte)
Notes
• A QUEST command is invalid when no ID has not been assigned.
• A QUEST command is invalid when a wildcard (*) is used in the ID when sending the command.
7 Quest Command Table
Command
QST
Obtains status information.
QPI
Obtains integrator/PICTURE information.
QWB
Obtains integrator/WHITE BALANCE information.
QPS
Obtains integrator/SCREEN information.
QSS
Obtains SETUP information.
QSO
Obtains Menu Integrator/OPTION information.
QSU
Obtains audio status.
QCI
Obtains time information.
QAP
Obtains various machine names.
Function
Data
····
Number direct
Effective Minimum Maximum memory
Checksum
Data
(2 Byte)
Function
RS-232C Adjustment
Last
ETX (03hex)