Chapter 50
Troubleshooting
S e n d f e e d b a c k t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m
show platform hardware fwm info pif all
•
show platform hardware fwm info lif all
•
show platform hardware fwm info global
•
show platform software zschk internal info
•
show platform software zschk internal msgs
•
show platform software statsclient msgs
•
show hardware internal gatos detail
•
•
show hardware internal gatos all-ports detail
•
show hardware internal altos detail
•
show hardware internal altos event-history errors
•
show hardware internal altos event-history messages
•
show platform fcfib fcflow
•
show platform fcfib event-history all
•
show platform fcfib unicasts
show platform fcfib unicasts forwarding-configuration
•
show platform fcfib vsan
•
show platform fcfib san-port-channel
•
show platform software fcfib devices
•
show platform software fcfib multipath
•
show platform software fcfib vsanidxtable
•
•
show platform software fcfib domainidxtable
•
show platform hardware fcfib pathselecttable
•
show platform hardware fcfib pathselecttable all
•
show platform software fcfib fctable-check
•
show fc2 internal event-history errors
•
show system internal liod liod_db
•
show system internal liod queues
show system internal liod state
•
show system internal liod time_db
•
show system internal rib domain
•
show system internal rib system-attributes
•
show system internal rib unicast
•
show system internal rib vsan-attributes
•
show system internal fcfwd fwidxmap if_index
•
•
show system internal fcfwd idxmap interface-to-port
•
show system internal fcfwd pcmap
•
show platform afm info global
•
show platform afm info attachment brief
OL-16597-01
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
show tech-support Command
50-15