Appendix A
XECfgParm.dat File Parameters
Table A-1
Configuration Parameter
engine.mdoDir
engine.SendHardwareBlock
engine.ShortDurationCallPeriod
engine.StartUpAuditEnabled
engine.SysCdrCollection
engine.SysCLIval
OL-18083-14
Cisco PGW 2200 Softswitch 9.x XECfgParm.dat File Configuration Parameters
Cisco PGW 2200 Softswitch Release 9.8 Software Installation and Configuration Guide
Understanding the XECfgParm.dat File Format
Definition
Location of call processing libraries.
Default: ../lib/
Note
Do not change this value.
To enable the Cisco PGW 2200 Softswitch to send
hardware-oriented blocking messages for any blocks that
originate from the media gateways:
true—Sends hardware-oriented blocking messages for
•
any blocks that originate from the media gateways.
false—Sends only maintenance-oriented blocking
•
messages for all blocking cases (default).
Note
The parameter is automatically added to the
XECfgParm.dat file during the patch installation.
Allows you to specify the period used to determine a short
duration call. Calls with a duration less than the specified
value are recorded as a short duration call in the CDR.
Default: 0
Valid values are: 0–30. A setting of 0 indicates that this
parameter is disabled. Short duration calls are not recorded
in the CDR when this parameter is disabled.
Audit is automatically invoked at
Cisco PGW 2200 Softswitch startup.
When the value is set to true the
Cisco PGW 2200 Softswitch automatically starts audit
when it comes up as the active host. This does not apply to
the standby host.
Default: false
Designates the format of CDRs.
Values:
true—Invalid for Release 7.4 and above.
•
false—Generates binary format CDRs (default)
•
Default: false
Note
Do not change this value. Setting this to a value of
true for Release 7.4 and higher is not valid and may
have deleterious effects on the system.
Enables or disables Calling Line Identity (CLI) validation
processing on calls.
Values:
•
true— Enables CLI validation
•
false—Disables CLI validation
Default: false