Sign In
Upload
Manuals
Brands
Pioneer Manuals
Air Conditioner
WYS012AMFI22RL
Pioneer WYS012AMFI22RL Manuals
Manuals and User Guides for Pioneer WYS012AMFI22RL. We have
1
Pioneer WYS012AMFI22RL manual available for free PDF download: Service & Troubleshooting Manual
Pioneer WYS012AMFI22RL Service & Troubleshooting Manual (156 pages)
Brand:
Pioneer
| Category:
Inverter
| Size: 11.6 MB
Table of Contents
Table of Contents
34
Display Function
35
Safety Features
36
Basic Functions
37
Table
37
Abbreviation
38
Fan Mode
38
Cooling Mode
38
Heating Mode(Heat Pump Units)
38
Auto-Mode
40
Drying Mode
40
Forced Operation Function
40
Sleep Function
40
Auto-Restart Function
40
Refrigerant Leakage Detection
41
Optional Functions
41
Table of Contents
42
First Time Installation Check
43
Refrigerant Recharging
45
Indoor Unit
46
Re-Installation
46
Outdoor Unit
48
Indoor Unit Disassembly(9K~24K)
50
Front Panel
68
Indoor Unit Disassembly(9K~24K)
68
Electrical Parts
75
Evaporator
78
Step Motor
81
Table of Contents
84
Outdoor Unit Matching Table
85
Outdoor Unit Dimensions
86
Outdoor Unit Disassembly
90
Panel Plate Disassembly
90
Electrical Components Disassembly
99
Fan Assembly Disassembly
103
Insulation Blanket Removal
105
Four-Way Valve Removal
106
Compressor Removal
107
Table of Contents
109
Safety Caution
111
General Troubleshooting
112
Complain Record Form
115
Information Inquiry
117
Error Diagnosis and Troubleshooting Without Error Code
120
Remote Maintenance
120
Field Maintenance
121
Quick Maintenance by Error Code
126
E0/EH 00/EH 0A / F4/EC 51 (EEPROM Parameter Error Diagnosis and Solution)
127
Troubleshooting by Error Code
127
E1/EL 01 (Indoor and Outdoor Unit Communication Error Diagnosis and Solution)
128
E2/EH 02 (Zero-Crossing Detection Error Diagnosis and Solution)
130
E3/EH 03 / F5/EC 07 (Fan Speed Outside of the Normal Range Diagnosis and Solution)
131
E4/EH 60/E5/EH 61/F1/EC 53/F2/EC 52/F3/EC 54/F6/EC56 (Open Circuit or Short Circuit of Temperature Sensor Diagnosis and Solution)
134
E7/EH 0B (Indoor PCB / Display Board Communication Error Diagnosis and Solution)
135
EC/EL 0C (Refrigerant Leakage Detection Diagnosis and Solution)
136
F0/PC 08 (Current Overload Protection Diagnosis and Solution)
137
P0/PC 00(IPM Malfunction or IGBT Over-Strong Current Protection Diagnosis and Solution)
138
P1/PC 01(over Voltage or too Low Voltage Protection Diagnosis and Solution)
139
P2/PC 02(High Temperature Protection of IPM Module or High Pressure Protection Diagnosis and Solution)
140
P4/PC 04(Inverter Compressor Drive Error Diagnosis and Solution)
142
P6/PC 03(High Pressure Protection or Low Pressure Protection Diagnosis and Solution)
143
Check Procedures
145
Advertisement
Advertisement
Related Products
Pioneer WYS012AMFI20RL-25
Pioneer WYS009AMFI22RL
Pioneer WYS009GMFI22RL
Pioneer WYS012GMFI22RL
Pioneer WYS018GMFI22RL
Pioneer WYS024GMFI22RL
Pioneer WYS009AMFI20RL-25
Pioneer WYS018GMFI22RL-25
Pioneer WYS009AMFI22RL-25
Pioneer WYS024GMFI22RL-25
Pioneer Categories
Car Receiver
Receiver
Stereo Receiver
Amplifier
CD Player
More Pioneer Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL