hit counter script

P0/Pc 00(Ipm Malfunction Or Igbt Over-Strong Current Protection Diagnosis And Solution) - Pioneer QUANTUM INVERTER Series Service & Troubleshooting Manual

Hide thumbs Also See for QUANTUM INVERTER Series:
Table of Contents

Advertisement

7.9

P0/PC 00(IPM malfunction or IGBT over-strong current protection diagnosis and solution)

Description: When the voltage signal the IPM sends to the compressor drive chip is abnormal, the LED displays the
failure code and the AC turns off.
Recommended parts to prepare:
• Connection wires
• IPM module board
• Outdoor fan assembly
• Compressor
• Outdoor PCB
Troubleshooting and repair:
Check the outdoor fan and the
Note: For certain models, outdoor PCB cannot be removed separately. In this case, the outdoor electric
control box should be replaced as a whole.
Check the wiring between
PCB and compressor.
Does an error exist?
NO
Check if the IPM is
installed correctly.
YES
IPM continuity check
Are the IPM terminal
resistance uniform?
YES
outdoor unit ventilation.
Is it in working order?
YES
Check the compressor
resistance values.
Are they uniform?
YES
Replace the outdoor PCB.
Troubleshooting
Ensure proper connections or
YES
replace the wires and connectors.
Correct the installation, tighten the
NO
screws and apply silicon grease
Replace the IPM board or
NO
replace the outdoor PCB.
Please refer to the solution of the
speed is operating outside of the
NO
normal range" malfunction.
Replace the compressor.
NO
30
"
fan

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents