Power Supply Modules
Attention
Make sure that one power supply module is always active.
Note
The system power requirements are lower than the power supply module capabilities. See the following table.
AC Power Supply
The dual power supplies can supply up to 800-W power across the input voltage range. The load is shared
when both power supply modules are plugged in and running at the same time.
Note
The system does not consume more than the capacity of one power supply module, so it will always operate
in full redundancy mode (2130 and 2140 only) when two power supply modules are installed.
Table 5: AC Power Supply Module Hardware Specifications
Input voltage
Maximum input
current
Maximum output
power
Frequency
Efficiency
Maximum
redundancy output
power
Redundancy
DC Power Supply
The power supplies can supply up to 350 W power across the input voltage range. The load is shared when
both power supply modules are plugged in and running at the same time.
Table 6: DC Power Supply Module Hardware Specifications
Input voltage
Cisco Firepower 2100 Series Hardware Installation Guide
28
2110
2120
100 to 240 V AC
< 4 A
250 W
50 to 60 Hz
85% at 50% load
—
—
2130
-48 to -60 V DC
2130
2140
< 6 A
400 W
89% at 50% load
800W
1+1 redundancy with dual power supply
modules
2140
Overview