Configuring Switch Alarms
Configuration Examples for Switch Alarms
Switch(config)# power-supply dual
These examples show how to display information when two power supplies are not present which results in a triggered
alarm.
Switch# show facility-alarm status
Source Severity Description Relay Time
Switch MAJOR 5 Redundant Pwr missing or failed NONE Mar 01
1993 00:23:52
Switch# show env power
POWER SUPPLY A is DC OK
POWER SUPPLY B is DC FAULTY <--
Switch# show hard led
SWITCH: 1
SYSTEM: GREEN
ALARM : ALT_RED_BLACK <--
Displaying Alarm Settings: Example
Switch# show alarm settings
Alarm relay mode: De-energized
Power Supply
Alarm
Enabled
Relay
Notifies
Disabled
Syslog
Enabled
Temperature-Primary
Alarm
Enabled
Thresholds
Relay
MAJ
Notifies
Enabled
Syslog
Enabled
Temperature-Secondary
Alarm
Disabled
Threshold
Relay
Notifies
Disabled
Syslog
Disabled
License-File-Corrupt
Alarm
Enabled
Relay
Notifies
Enabled
Syslog
Enabled
Switch# show alarm settings
Alarm relay mode: De-energized
Power Supply
Alarm
Relay
Notifies
Syslog
Temperature-Primary
Alarm
Thresholds
Relay
Notifies
Syslog
Temperature-Secondary
Alarm
Threshold
Relay
MAX: 95C
MIN: -20C
Enabled
Disabled
Enabled
Enabled
MAX: 95C
MAJ
Enabled
Enabled
Disabled
MIN:
-20C