Configuring Link State Tracking
Additional References
(Up):Interface up (Dwn):Interface Down (Dis):Interface disabled
Creating a Link State Group: Example
This example shows how to create a link state group and configure the interfaces:
Switch# configure terminal
Switch(config)# link state track 1
Switch(config)# interface range GigabitEthernet1/17 -2
Switch(config-if)# link state group 1 upstream
Switch(config-if)# interface GigabitEthernet1/17
Switch(config-if)# link state group 1 downstream
Switch(config-if)# interface GigabitEthernet1/17
Switch(config-if)# link state group 1 downstream
Switch(config-if)# interface GigabitEthernet1/18
Switch(config-if)# link state group 1 downstream
Switch(config-if)# end
Additional References
The following sections provide references related to switch administration: