hit counter script

Alarm Reporting - Cisco ASR 900 Series Configuration Manual

1 port oc48/ 4 port oc12/oc3 + 12 port t1/e1 + 4 port t3/e3 cem interface module
Hide thumbs Also See for ASR 900 Series:
Table of Contents

Advertisement

Alarm Reporting

shutdown
end
Use the no shutdown command to disable the interface.
Note
Alarm Reporting
Enables reporting for all or selected alarms.
• b1-tca — Enables BER threshold crossing alarm for B1.
• b2-tca — Enables BER threshold crossing alarm for B2.
• b3-tca — Enables BER threshold crossing alarm for B3.
• lais —Enables line alarm indication signal.
• lom — Enables loss of multiframe signal.
• lrdi — Enables line remote defect indication signal.
• pais — Enables path alarm indication signal.
• plop — Enables loss of pointer failure signal for a path.
• pplm — Enables path payload mismatch indication.
• prdi — Enables path remote defect indication signal.
• puneq — Enables path unequipped (path label equivalent to zero) signal.
• sd-ber — Enables LBIP BER in excess of SD threshold.
• sf-ber — Enables LBIP BER in excess of SF threshold.
• slof — Enables section loss of frame signal.
• slos — Enables section loss of signal.
Configuring Alarm Reporting
To configure alarm reporting:
enable
configure terminal
controller sdh 0/0/16
alarm-report [b1-tca | b2-tca | b3-tca | lais | lom | lrdi | pais | plop | pplm | prdi |
puneq | sd-ber | sf-ber | lof | los]
end
Note
To restore the system to its default condition, use the no form of the alarm report command.
1 port OC48/ 4 port OC12/OC3 + 12 port T1/E1 + 4 port T3/E3 CEM Interface Module Configuration Guide, Cisco
IOS XE Fuji 16.7.x (Cisco ASR 900 Series)
116
Configuring SDH

Advertisement

Table of Contents
loading

Table of Contents