Managing and Monitoring SONET Line
PATH TRACE BUFFER : UNSTABLE
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SONET/SDH Path Tables
INTERVAL
05:58-05:58
OC3.STS1 0/0/16 is up.
Hardware is
Applique type is VT1.5
STS-1 1, VTG 1, T1 1 (VT1.5 1/1/1) is down
VT Receiver has no alarm.
Receiver is getting AIS.
Framing is unframed, Clock Source is Internal
t1
Data in current interval (0 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
0 Unavail Secs, 0 Stuffed Secs
STS-1 1, VTG 1, T1 2 (VT1.5 1/1/2) is down
VT Receiver has no alarm.
Receiver is getting AIS.
The following table shows each field and its description.
Table 5: Field Description
Field
SONET 0/0/16 is up
Port configured rate: OC3
SECTION: LOS = 0 LOF = 0 BIP = 0
SONET Section Tables:
INTERVAL CV ES SES SEFS
05:50-05:58 0 0 0 0
LINE:
AIS = 0 RDI = 0 REI = 0 BIP(B2) = 0
Asserted/Active Alarms: None
BER thresholds: SF = 10e-3 SD = 10e-6
K1 = 00, K2 = 00
1 port OC48/ 4 port OC12/OC3 + 12 port T1/E1 + 4 port T3/E3 CEM Interface Module Configuration Guide, Cisco
IOS XE Fuji 16.7.x (Cisco ASR 900 Series)
84
CV
ES
SES
UAS
0
0
0
0
======> present status of the path
A900-IMA3G-IMSG
=====> mode of the path
................
................
................
................
====> status of the SPE (t1)
===> alarm of the SPE (t1)
=====> framing of the T1, clock of the
Description
Shows that the SONET controller is operating. The
controller's state can be up, down, or administratively
down.
Shows the rate configured on the port.
Shows the section level alarm counters.
Shows the PMON for the port.
Shows the line level alarm counters.
Shows the active alarms on the port.
Shows BER thresholds.
Shows the K1 and K2 values.
Configuring SONET