Verifying the Supported Pluggables
Link reach for 62.5u fiber (m)
Nominal laser wavelength
DWDM wavelength fraction
Supported options
Supported enhanced options
Diagnostic monitoring
Transceiver temperature operating range
Minimum operating temperature
Maximum operating temperature
High temperature alarm threshold
High temperature warning threshold
Low temperature warning threshold
Low temperature alarm threshold
High voltage alarm threshold
High voltage warning threshold
Low voltage warning threshold
Low voltage alarm threshold
High laser bias current alarm threshold
High laser bias current warning threshold = 65.000 mAmps
Low laser bias current warning threshold
Low laser bias current alarm threshold
High transmit power alarm threshold
High transmit power warning threshold
Low transmit power warning threshold
Low transmit power alarm threshold
High receive power alarm threshold
Low receive power alarm threshold
High receive power warning threshold
Low receive power warning threshold
External Calibration: bias current slope
External Calibration: bias current offset = 0
show hw-module subslot <slot/bay> transceiver <port> idprom brief:
sh hw-module subslot 0/7 transceiver 6 idprom brief
IDPROM for transceiver SPA-1T8S-10CS_7/6:
Description
Transceiver Type:
Product Identifier (PID)
Vendor Revision
Serial Number (SN)
Vendor Name
Vendor OUI (IEEE company ID)
CLEI code
Cisco part number
Device State
Date code (yy/mm/dd)
Connector type
Encoding
1 port OC48/ 4 port OC12/OC3 + 12 port T1/E1 + 4 port T3/E3 CEM Interface Module Configuration Guide, Cisco
IOS XE Fuji 16.7.x (Cisco ASR 900 Series)
90
LR-2(80km) (0)
LR-3(80km) (0)
DX(40KM) (0)
HX(40km) (0)
ZX(80km) (0)
VX(100km) (0)
1xFC, 2xFC-SM(10km) (0)
ESCON-SM(20km) (0)
= SR(2km) (0)
IR-1(15km) (0)
IR-2(40km) (0)
LR-1(40km) (0)
LR-2(80km) (0)
LR-3(80km) (0)
DX(40KM) (0)
HX(40km) (0)
ZX(80km) (0)
VX(100km) (0)
1xFC, 2xFC-SM(10km) (0)
ESCON-SM(20km) (0)
= 1310 nm.
= 1310.0
nm.
= Tx disable
Tx fault signal
Loss of signal (standard implementation)
= Alarms for monitored parameters
Software Rx LOS monitoring
= Digital diagnostics supported
Diagnostics are externally calibrated
Rx power measured is "Average power"
= -40 C to 85 C (industrial)
= -40 C
= 85 C
= +90.000 C
= +85.000 C
=
-40.000 C
=
-45.000 C
= 3630.0 mVolts
= 3470.0 mVolts
= 3140.0 mVolts
= 2971.2 mVolts
= 85.000 mAmps
= 4.000 mAmps
= 2.000 mAmps
=
4.0 dBm
=
2.0 dBm
= -7.0 dBm
= -9.0 dBm
=
1.0 dBm
= -26.0 dBm
= -1.0 dBm
= -24.9 dBm
= 1.000
= SFP or SFP+ optics (type 3)
= ONS SE Z1 (406)
= ONS-SE-Z1
= A
= FNS19251NQ0
= CISCO-FINISAR
= 00.90.65 (36965)
= WMOTCZPAAA
= 10-1971-04
= Enabled.
= 15/06/19
= LC.
= 8B10B
Configuring SONET