hit counter script

Cisco ubr7111e Hardware Installation Manual page 80

Universal broadband router
Hide thumbs Also See for ubr7111e:
Table of Contents

Advertisement

Environmental Monitoring and Reporting Functions
If the environmental status is not normal, the system reports the worst-case status level. Following is a
sample overvoltage warning:
Router# show environment
Warning: +3.3 V measured at +3.41 V
The show environment last command retrieves and displays the NVRAM log, which provides a record
of environmental status readings. Air temperature is measured and displayed, and the voltage supplied
by the power supply is also displayed.
Following is sample output of the show environment last command:
Router# show environment last
chassis core
chassis inlet
chassis outlet 1
chassis outlet 2
+2.5 V
+3.3 V
+5.15 V
+12.3 V
+12.3 V
-12.5 V
The show environment table command displays the temperature and voltage thresholds for each
temperature sensor and for each monitored status level, which are related to those thresholds listed in
Table 6-1
Following is sample output of the show environment table command:
Router# show environment table
Sample Point
chassis core
chassis inlet
chassis outlet 1
chassis outlet 2
+2.5 V
+3.3 V
+5.15 V
+12.3 V
+12.3 V
-12.5 V
Temperature ranges and values are subject to change.
Note
The show environment all command displays an extended report that includes temperature readings and
voltage readings.
Following is sample output of the show environment all command:
Router# show environment all
Power Supply:
Temperature readings:
Cisco uBR7100 Series and Cisco uBR7100E Series Universal Broadband Router Hardware Installation Guide
6-4
previously measured at 34C/93F
previously measured at 28C/82F
previously measured at 31C/87F
previously measured at 33C/91F
previously measured at +2.59
previously measured at +3.32
previously measured at +5.13
previously measured at +12.99
previously measured at +12.33
previously measured at -12.43
and
Table
6-2.
LowCritical
+2.35
+3.11
+4.88
+11.53
+11.53
-10.20
Power supply is standard power supply. Unit is on.
chassis core
measured at 33C/91F
chassis inlet
measured at 27C/80F
chassis outlet 1 measured at 30C/86F
chassis outlet 2 measured at 32C/89F
LowWarning
HighWarning
49C/120F
43C/109F
46C/114F
47C/116F
+2.39
+2.69
+3.19
+3.39
+5.00
+5.23
+11.77
+12.76
+11.77
+12.76
-11.24
-13.71
Chapter 6
Maintenance
HighCritical
54C/129F
48C/118F
51C/123F
52C/125F
+2.72
+3.47
+5.39
+13.05
+13.05
-14.33
OL-5916-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ubr7114Ubr7111Ubr7100 seriesUbr7100e seriesUbr7114e

Table of Contents