Table 1-1
Table 1-1
Cisco 7204 Physical Specifications
Description
Midplane
Dimensions (H x W x D)
Weight
Heat dissipation
AC-input voltage rating
AC-input current rating
AC-input frequency rating
AC-input cable
DC-output power
DC-input voltage rating
DC-input current rating
DC voltages supplied and
maximum, steady-state
current ratings
DC-input cable
Airflow
Temperature
Humidity
1. Mbps = megabits per second.
2. Btu = British thermal units.
3. VAC = volts alternating current.
4. A = amperes.
5. Hz = hertz.
6. AWG = American Wire Gauge.
7. VDC = volts direct current.
8. cfm = cubic feet per minute.
For a chassis footprint, additional dimensions, and clearance requirements for the Cisco 7204 perimeter,
Note
refer to the section
OL-5101-02
lists the Cisco 7204 router physical specifications and power requirements.
Specification
Two primary PCI buses and one secondary PCI bus with an aggregate bandwidth of 600 Mbps
5.25 in. x 16.8 in. x 17 in. (13.34 cm x 42.67 cm x 43.18 cm)
Chassis fully configured with a network processing engine, I/O controller, 4 port adapters,
2 power supplies, and a fan tray: ~ 50 lb (22.7 kg)
2
370W (1262 Btu
)
3
100-240 VAC
wide input with power factor correction
4
5A
at 100-240 VAC with the chassis fully configured
5
50/60 Hz
6
18 AWG
three-wire cable, with a three-lead IEC-320 receptacle on the power supply end, and
a country-dependent plug on the power source end
280W maximum (with either a single or a dual power supply configuration)
7
–48 VDC
nominal in North America
–60 VDC nominal in the European Community
13A at –48 VDC (370W/–48 VDC = 7.7A typical draw)
8A at –60 VDC (370W/–60 VDC = 6.2A typical draw)
+5.2V @ 30A
+12.2V @ 9A
–12.0V @ 1.5A
+3.5V @ 13A
In accordance with local and national wiring regulations
8
~80 cfm
32 to 104°F (0 to 40°C) operating; –4 to 149°F (–20 to 65°C) nonoperating
10 to 90% noncondensing
"Site Requirements" section on page 2-4