Page 2
Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM RS930L Communication Ports Technical Specifications Installation Manual Certification 04/2021 C79000-G8976-1034-09...
Page 3
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
Preface Contacting Siemens • Contact a local Siemens representative from Sales, Technical Support, Training, etc. • Ask questions or share knowledge with fellow Siemens customers and the support community Contacting Siemens Address Siemens AG Industry Sector 300 Applewood Crescent Concord, Ontario...
Division 2), optional conformal coating and a galvanized steel enclosure allows the RUGGEDCOM RS930L to be placed in almost any location. The RUGGEDCOM RS930L can be mounted on a DIN rail or panel for efficient use of cabinet space. The integrated power supply supports a wide range of voltages (88-300 VDC or 85-264 VAC) for worldwide operability.
Terminal blocks for reliable maintenance free connections • CSA/UL 62368-1 safety approved to 85 °C (185 °F) Description The RUGGEDCOM RS930L features various ports, controls and indicator LEDs on the front panel for connecting, configuring and troubleshooting the device. RUGGEDCOM RS930L Installation Manual, 04/2021, C79000-G8976-1034-09...
Page 12
RS232 Console Port (Serial) Failsafe Alarm Relay Chassis Ground Connection Power Supply Terminal Block Figure 1.1 RUGGEDCOM RS930L POWER LED Illuminates green during boot up and when power is supplied to the device. ALARM LED Illuminates red when an alarm condition exists.
Introduction 1.3 Required Tools and Materials Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RS930L: Tools/Materials Purpose AC power cord (16 AWG) For connecting power to the device. CAT-5 Ethernet cables For connecting the device to a LAN.
This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
If any item is missing or damaged, contact Siemens for assistance. Installing the Device in Hazardous Locations The RUGGEDCOM RS930L is designed to comply with the safety standards for Class I, Division 2 hazardous locations where concentrations of flammable gases, vapors or liquids may be present, as opposed to normal operating environments.
Substitution of the components may impair suitability for Class I, Division 2. Mounting the Device The RUGGEDCOM RS930L is designed for maximum mounting and display flexibility. It can be equipped with adapters that allow it to be attached to a DIN rail or panel.
2.4.1 Mounting the Device on a DIN Rail The RUGGEDCOM RS930L can be ordered with a DIN rail adapter preinstalled on the back of the chassis. Use the adapter to mount the device to a standard 35 mm (1.4 in) IEC/EN 60715 or TS35 DIN rail.
2.4.2 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RS930L can be equipped with panel adapters on the top and bottom of the chassis. The adapters allow the device to be attached to a panel using screws.
NO contact and closes the NC (Normally Closed) contact. Note Control of the failsafe relay output is configurable through RUGGEDCOM RS930L . One common application for this relay is to signal an alarm if a power failure occurs.
Common Normally Open Figure 2.4 Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM RS930L supports power input from a single high AC/DC or low DC power supply. Note • For 110/230 VAC rated equipment, an appropriately rated AC circuit breaker must be installed.
Note Torque all terminal connections to 0.6 N·m (5 lbf-in). Secure the power terminal block to the device. RUGGEDCOM RS930L Installation Manual, 04/2021, C79000-G8976-1034-09...
Page 22
2.6.1 Connecting High AC/DC Power Connect the positive wire from the power source to the positive/live (+/L) terminal on the terminal block. Positive/Live (+/L) Terminal Negative/Neutral (-/N) Terminal Surge Ground Terminal Braided Ground Cable Figure 2.5 Terminal Block Wiring RUGGEDCOM RS930L Installation Manual, 04/2021, C79000-G8976-1034-09...
2.6.2 Connecting Low DC Power RUGGEDCOM RS930L's equipped with 24 or 48 V power supply inputs feature reverse polarity protection and dual power supply inputs allowing the device to accept redundant connections to a single DC power supply.
Page 24
Negative Terminal Surge Ground Terminal Braided Ground Cable Figure 2.7 Terminal Block Wiring – Single DC Power Supply Inputs Connect the negative wire from the power source to the negative terminal on the terminal block. RUGGEDCOM RS930L Installation Manual, 04/2021, C79000-G8976-1034-09...
Page 25
Connect the ground wire from the power source to the chassis groun terminal on the terminal block. RUGGEDCOM RS930L Installation Manual, 04/2021, C79000-G8976-1034-09...
This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RS930L console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM ROS Configuration Manual for the RUGGEDCOM RS930L.
Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RS930L console and Web interfaces via the device's IP address. The factory default IP address for the RUGGEDCOM RS930L is https://192.168.0.1. For more information about available ports, refer to "Communication Ports (Page...
Communication Ports The RUGGEDCOM RS930L can be equipped with various types of communication ports to enhance its abilities and performance. Ports 1 to 6 Port 7 Port 9 Figure 4.1 Port Assignment Port Type 1 to 6 Copper Ethernet Ports (10/100Base-TX)
Page 29
No link detected Pin-Out The following is the pin-out for the RJ45 male connectors: Figure 4.3 RJ45 Ethernet Port Pin Configuration Name Description Receive Data+ Receive Data- Transmit Data+ Reserved (Do Not Connect) Reserved (Do Not Connect) RUGGEDCOM RS930L Installation Manual, 04/2021, C79000-G8976-1034-09...
Universal and Long-Reach EoVDSL ports are physically indistinguishable from each other. However, the port type can be determined either from the order code or through the RUGGEDCOM RS930L user interface. EoVDSL ports can be connected using RJ11 male connectors. IMPORTANT Universal and Long-Reach EoVDSL ports (master or slave) must be connected to EoVDSL ports (slave or master) of the same type.
EoVDSL ports are designed to be used on private communications lines for point-to-point connections and are not to be connected to the Public Switched Telephone Network (PSTN). • To reduce the risk of fire, use only #26 AWG or larger telecommunication line cord. RUGGEDCOM RS930L Installation Manual, 04/2021, C79000-G8976-1034-09...
4.2.2 Configuration and Setup If the RUGGEDCOM RS930L and another device both have Universal EoVDSL ports, configure one device to be the Master and the other the Slave. If both devices have a Long-Reach EoVDSL port, no Master/Slave configuration is necessary, since the ports will already be fixed as Master or Slave.
Page 33
SNR. By configuring the Rescan Mode parameter in RUGGEDCOM RS930L, the user can control at which point the scan process will be restarted when the line conditions degrade.
125 VAC 0.5 A, 62.5 W 220 VDC 0.24 A, 60 W 250 VAC 0.25 A, 62.5 W Supported Networking Standards The following networking standards are supported by RUGGEDCOM RS930L: Standard 10 Mbps 100 Mbps 1000 Mbps Ports Notes Ports Ports IEEE 802.3x...
Auto-crossover and auto-polarity. Typical distance. Dependent on the number of connectors and splices. RMS 1 minute. Operating Environment The RUGGEDCOM RS930L is rated to operate under the following environmental conditions. Ambient Operating -40 to 85 °C (-40 to 185 °F)
Certification The RUGGEDCOM RS930L device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. Approvals This section details the standards to which the RUGGEDCOM RS930L complies. 6.1.1 This device meets the requirements of the following Canadian Standards Association (CSA) standards under certificate 1550963: •...
Title 21 Code of Federal Regulations (CFR) – Chapter I – Sub-chapter J – Radiological Health 6.1.4 ISED This device is declared by Siemens AG to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) 6.1.5...
A copy of the Declaration of Conformity is available via Siemens Industry Online Support at https://support.industry.siemens.com/cs/ww/en/view/89855782. 6.1.8 RoHS This device is declared by Siemens AG to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: •...
• IEC 61000-6-2 Electromagnetic Compatibility (EMC) – Part 6-2: Generic Standards – Immunity for Industrial Environments EMC and Environmental Type Tests The RUGGEDCOM RS930L has passed the following Electromagnetic Compatibility (EMC) and environmental tests. EMC Type Tests Test Description Test Levels...
Page 46
EMC Immunity Type Tests per IEEE 1613 Note The RUGGEDCOM RS930L meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Class 1 allows for temporary communication loss, while Class 2 requires error-free and interrupted communications.
Page 47
95% (Non- Heat, Cyclic) Condensing), 55 °C (131 °F), 6 Cycles IEC 60255-21-1 Vibration 2 g @ 10 to 150 Hz Class 2 IEC 60255-21-2 Shock 30 g @ 11 ms Class 2 RUGGEDCOM RS930L Installation Manual, 04/2021, C79000-G8976-1034-09...
Page 48
Further Information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...