Page 2
Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM RS900F Communication Ports Technical Specifications Installation Manual Certification 02/2020 C79000-G8976-1350-04...
Page 3
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommend- ed or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
However, deviations between the product and the documentation may exist. Siemens shall not be liable for any errors or omissions contained herein or for conse- quential damages in connection with the furnishing, performance, or use of this ma- terial.
Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
RUGGEDCOM RS900F to be placed in almost any location. The RUGGEDCOM RS900F can be mounted on a DIN rail or panel for efficient use of cabinet space. The integrated power supply supports a wide range of voltages (88-300 VDC or...
Terminal blocks for reliable maintenance free connections • CSA/UL 60950-1 safety approved to 85 °C (185 °F) Description The RUGGEDCOM RS900F features various ports, controls and indicator LEDs on the front panel for connecting, configuring and troubleshooting the device. POWER LED ALARM LED...
"Connecting Power (Page 13)" "Power Supply Specifications (Page 25)". Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RS900F: Tools/Materials Purpose AC power cord (16 AWG) For connecting power to the device. Multi-mode and/or single-mode fiber optic cables For connecting the device to a LAN.
Siemens also does not recommend using copper Ethernet ports to interface with de- vices in the field across distances that could produce high levels of ground potential rise (i.e.
Page 14
NOTICE Worn, damaged or missing seals must be replaced immediately. Replacement seals are available for purchase from Siemens. For more information, contact a Siemens Sales representative. There are three ways to determine if a security seal has been tampered with: •...
This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
If any item is missing or damaged, contact Siemens for assistance. Installing the Device in Hazardous Locations The RUGGEDCOM RS900F is designed to comply with the safety standards for Class I, Division 2, Zone 2 hazardous locations where concentrations of flammable gases, va- pors or liquids may be present, as opposed to normal operating environments.
2.3.1 Mounting the Device on a DIN Rail The RUGGEDCOM RS900F can be ordered with a DIN rail adapter preinstalled on the back of the chassis. Use the adapter to mount the device to a standard 35 mm (1.4 in) IEC/EN 60715 or TS35 DIN rail.
Page 19
Insert a flathead screwdriver into the slot of the sliding release and move it down. Push the device against the bottom of the DIN rail, then let go of the sliding re- lease to latch the device. RUGGEDCOM RS900F Installation Manual, 02/2020, C79000-G8976-1350-04...
2.3.2 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RS900F can be equipped with panel adapters pre-installed on the top and bottom of the chassis. The adapters allow the device to be attached to a panel using screws.
Control of the failsafe relay output is configurable through RUGGEDCOM RS900F . One common application for this relay is to signal an alarm if a power failure occurs. For more information, refer to the RUGGEDCOM RS900F User Guide for the RUGGED- COM RS900F.
Common Normally Open Figure 2.5 Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM RS900F supports power input from a single high AC/DC or low DC power supply. IMPORTANT • For 110/230 VAC rated equipment, an appropriately rated AC circuit breaker must be installed.
Note Torque all terminal connections to 0.6 N·m (5 lbf-in). Secure the power terminal block to the device. RUGGEDCOM RS900F Installation Manual, 02/2020, C79000-G8976-1350-04...
Page 24
Connect the positive wire from the power source to the positive/live (+/L) termi- nal on the terminal block. Positive/Live (+/L) Terminal Negative/Neutral (-/N) Terminal Surge Ground Terminal Braided Ground Cable Figure 2.6 Terminal Block Wiring RUGGEDCOM RS900F Installation Manual, 02/2020, C79000-G8976-1350-04...
2.5.2 Connecting Low DC Power RUGGEDCOM RS900F's equipped with 24 or 48 V power supply inputs feature reverse polarity protection and dual power supply inputs allowing the device to accept re- dundant connections to a single DC power supply.
Page 26
Negative Terminal Surge Ground Terminal Braided Ground Cable Figure 2.8 Terminal Block Wiring – Single DC Power Supply Inputs Connect the negative wire from the power source to the negative terminal on the terminal block. RUGGEDCOM RS900F Installation Manual, 02/2020, C79000-G8976-1350-04...
Page 27
Connect the ground wire from the power source to the chassis groun terminal on the terminal block. RUGGEDCOM RS900F Installation Manual, 02/2020, C79000-G8976-1350-04...
This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RS900F console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM RS900F User Guide for the RUGGEDCOM RS900F.
Ethernet Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RS900F console and Web interfaces via the device's IP address. The factory default IP address for the RUGGEDCOM RS900F is https://- 192.168.0.1.
Communication Ports The RUGGEDCOM RS900F can be equipped with various types of communication ports to enhance its abilities and performance. Ports 1 to 6 Ports 7 and 8 Port 9 Figure 4.1 Port Assignment Port Type 1 to 6 Copper Ethernet Ports (10/100Base-TX)
Page 31
RJ45 Ethernet Port Pin Config- Reserved (Do Not Connect) uration Transmit Data- Reserved (Do Not Connect) Reserved (Do Not Connect) Specifications For specifications on the available copper Ethernet ports, refer to "Copper Ethernet Port Specifications (Page 26)". RUGGEDCOM RS900F Installation Manual, 02/2020, C79000-G8976-1350-04...
Each port features an LED that indicates the link/activity state of the port. State Description Yellow (Solid) Link established Yellow (Blinking) Link activity No link detected Specifications For specifications on the available fiber optic Ethernet ports, refer to "Fiber Optic Eth- ernet Port Specifications (Page 27)". RUGGEDCOM RS900F Installation Manual, 02/2020, C79000-G8976-1350-04...
ü ü IEEE 802.3z 1000Base-LX ü Copper Ethernet Port Specifications The following details the specifications for copper Ethernet ports that can be ordered with the RUGGEDCOM RS900F. Speed 10/100Base-TX Connector RJ45 Duplex FDX/HDX Cable Type > CAT 5...
3 dBm. To convert from peak to average, subtract 3 dBm. • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. Operating Environment The RUGGEDCOM RS900F is rated to operate under the following environmental con- ditions.
Certification The RUGGEDCOM RS900F device has been thoroughly tested to guarantee its confor- mance with recognized standards and has received approval from recognized regula- tory agencies. Approvals This section details the standards to which the RUGGEDCOM RS900F complies. 6.1.1 This device meets the requirements of the following Canadian Standards Association (CSA) standards under certificate 16.70065161:...
Explosive Atmospheres – Part 15: Equipment Protection by Type of Protection "n" 6.1.3 European Union (EU) This device is declared by Siemens AG to comply with essential requirements and other relevant provisions of the following EU directives: • EN 60950-1 Information Technology Equipment –...
Methods of Measurement The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens AG. For contact information, refer to "Contacting Siemens (Page vii)".
Information Technology Equipment – Safety – Part 1: General Requirements 6.1.8 RoHS This device is declared by Siemens AG to meet the requirements of the following Ro- HS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: •...
Communication Networks and Systems in Substations – Part 3: General Require- ments • NEMA TS-2 Traffic Controller Assemblies with NTCIP Requirements EMC and Environmental Type Tests The RUGGEDCOM RS900F has passed the following Electromagnetic Compatibility (EMC) and environmental tests. EMC Type Tests Test Description Test Levels...
Page 45
EMC Immunity Type Tests per IEEE 1613 Note The RUGGEDCOM RS900F meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Class 1 allows for temporary communica- tion loss, while Class 2 requires error-free and interrupted communications.
Page 46
95% (Non-Con- Heat, Cyclic) densing), 55 °C (131 °F), 6 Cycles IEC 60255-21-1 Vibration 2 g @ 10 to 150 Hz Class 2 IEC 60255-21-2 Shock 30 g @ 11 ms Class 2 RUGGEDCOM RS900F Installation Manual, 02/2020, C79000-G8976-1350-04...
Page 47
Certification 6.2 EMC and Environmental Type Tests RUGGEDCOM RS900F Installation Manual, 02/2020, C79000-G8976-1350-04...
Page 48
Further Information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...