hit counter script
Siemens RUGGEDCOM RS900GP Installation Manual
Siemens RUGGEDCOM RS900GP Installation Manual

Siemens RUGGEDCOM RS900GP Installation Manual

Simatic net rugged ethernet switches
Hide thumbs Also See for RUGGEDCOM RS900GP:

Advertisement

Quick Links

Installation Manual
SIMATIC NET
Rugged Ethernet Switches
RUGGEDCOM RS900GP
Edition
06/2020
https://www.siemens.com

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RUGGEDCOM RS900GP

  • Page 1 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RS900GP Edition 06/2020 https://www.siemens.com...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM RS900GP Communication Ports Technical Specifications Installation Manual Certification 06/2020 C79000-G8976-1026-07...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommend- ed or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Accessing Documentation ....................... v Registered Trademarks ......................v Warranty ..........................v Training ..........................vi Customer Support ........................vi Contacting Siemens ....................... vii Introduction ........................... 1 Feature Highlights ....................1 Description ......................2 Required Tools and Materials ................. 3 Decommissioning and Disposal ................3 Supported Fiber Optic Cables ................
  • Page 5 FCC ........................32 6.1.4 FDA/CDRH ......................32 6.1.5 ISED ........................32 6.1.6 ISO ........................33 6.1.7 ACMA ........................33 6.1.8 RoHS ........................33 6.1.9 Other Approvals ....................34 EMC and Environmental Type Tests ..............34 RUGGEDCOM RS900GP Installation Manual, 06/2020, C79000-G8976-1026-07...
  • Page 6: Preface

    Warranty Siemens warrants this product for a period of five (5) years from the date of pur- chase, conditional upon the return to factory for maintenance during the warranty term.
  • Page 7: Training

    Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
  • Page 8: Contacting Siemens

    Preface Contacting Siemens • Contact a local Siemens representative from Sales, Technical Support, Training, etc. • Ask questions or share knowledge with fellow Siemens customers and the support community Contacting Siemens Address Siemens AG Industry Sector 300 Applewood Crescent Concord, Ontario...
  • Page 9 Preface Contacting Siemens viii RUGGEDCOM RS900GP Installation Manual, 06/2020, C79000-G8976-1026-07...
  • Page 10: Introduction

    An operating temperature range of -40 to 85 °C (-40 to 185 °F) coupled with optional conformal coating and a powder coated aluminum enclosure allows the RUGGEDCOM RS900GP to be placed in almost any location.
  • Page 11: Description

    Complies with IEEE 802.3af, 15 W x 8 output when using 48 VDC power supplies Description The RUGGEDCOM RS900GP features various ports, controls and indicator LEDs on the front panel for connecting, configuring and troubleshooting the device. Fiber Optic or SFP (Small Form-Factor Pluggable) Ethernet Ports...
  • Page 12: Required Tools And Materials

    • "Connecting Power (Page 12)" • "Power Supply Specifications (Page 23)" Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RS900GP: Tools/Materials Purpose DC power cord (16 AWG) For connecting power to the device.
  • Page 13: Supported Fiber Optic Cables

    1000Base-SX 10GBase-SR OM1 (62.5/125) — 1300 2000 — — OM2 (50/125) — 1300 2000 — — OM3 (50/125) 1500 — 1300 2000 — — OM4 (50/125) 3500 — 1300 2000 — — Laser optimized. RUGGEDCOM RS900GP Installation Manual, 06/2020, C79000-G8976-1026-07...
  • Page 14: Installing The Device

    Access must only be possible through the use of a tool, lock and key, or other means of security, and controlled by the authority re- sponsible for the location. Note RUGGEDCOM RS900GP Installation Manual, 06/2020, C79000-G8976-1026-07...
  • Page 15: Unpacking The Device

    If any item is missing or damaged, contact Siemens for assistance. Cabling Recommendations Siemens does not recommend the use of copper cabling of any length for critical, re- al-time substation automation applications. All copper Ethernet ports on RUGGED- COM products include transient suppression circuitry to protect against damage from electrical transients and conform with IEC 61850-3 and IEEE 1613 Class 1 standards.
  • Page 16: 2.3.1 Mounting The Device On A Din Rail

    2.3.1 Mounting the Device on a DIN Rail For DIN rail installations, the RUGGEDCOM RS900GP can be ordered with a DIN rail adapterthat can be affixed to the back of the chassis. Use the adapter to mount the device to a standard 35 mm (1.4 in) IEC/EN 60715 or TS35 DIN rail.
  • Page 17 Insert a flathead screw driver into the slot of the sliding release and move it down. Push the device against the bottom of the DIN rail. Let go of the sliding release to latch the device. RUGGEDCOM RS900GP Installation Manual, 06/2020, C79000-G8976-1026-07...
  • Page 18: 2.3.2 Mounting The Device To A Panel

    Lift the device off the DIN rail. 2.3.2 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RS900GP can be equipped with panel adapters that allow the device to be attached to a panel in multiple orientations. RUGGEDCOM RS900GP...
  • Page 19 Place the device against (side or rear mount orientation) or insert it into (front mount orientation) the panel and align the adapters with the mounting holes. Panel Adapter Screw Figure 2.5 Panel Mounting (Rear Mount Orientation Shown) RUGGEDCOM RS900GP Installation Manual, 06/2020, C79000-G8976-1026-07...
  • Page 20: Grounding The Device

    Control of the failsafe relay output is configurable through RUGGEDCOM RS900GP . One common application for this relay is to signal an alarm if a power failure oc- curs. For more information, refer to the RUGGEDCOM RS900GP User Guide for the RUGGEDCOM RS900GP.
  • Page 21: Connecting Power

    Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM RS900GP features an integrated low DC power supply that accepts input from redudant power sources. Requirements for the power source(s) is depen- dent on the IEEE 802.3 standard required by the application:...
  • Page 22 Connect the ground terminal on the power source to the chassis ground termi- nal on the device. If a redundant power source is required, repeat Step 1 Step 4 using the sec- ond terminal. RUGGEDCOM RS900GP Installation Manual, 06/2020, C79000-G8976-1026-07...
  • Page 23 Installing the Device 2.6 Connecting Power RUGGEDCOM RS900GP Installation Manual, 06/2020, C79000-G8976-1026-07...
  • Page 24: Device Management

    The following describes the various methods for accessing the RUGGEDCOM RS900GP console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM RS900GP User Guide for the RUGGEDCOM RS900GP. Serial Console Port Connect a PC or terminal directly to the serial console port to access the boot-time control and RUGGEDCOM ROS console interface.
  • Page 25: Configuring The Device

    Communication Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RS900GP console and Web interfaces via the device's IP address. The factory default IP address for the RUGGEDCOM RS900GP is https://- 192.168.0.1.
  • Page 26: Communication Ports

    Gigabit Ethernet capable ports, for which many fiber transceiver and cop- per options are available. Each communication port type has a specific place in the RUGGEDCOM RS900GP chassis. Copper Ethernet, SFP or Fiber Optic Ethernet Ports (Ports 9 and 10) Standard PoE Ports (Ports 1 to 8) Figure 4.1...
  • Page 27 The following are the pin-out descriptions for the RJ45 and micro-D connectors:   Name Description 10/100Base- 1000Base- BI_DB+ Receive Da- ta+ or Bi-Di- rectional Figure 4.4 RJ45 Port Pin Configuration BI_DB- Receive Da- ta- or Bi-Di- rectional BI_DA+ Transmit Data+ or Bi- Directional RUGGEDCOM RS900GP Installation Manual, 06/2020, C79000-G8976-1026-07...
  • Page 28: Poe Ports

    24)". PoE Ports The RUGGEDCOM RS900GP supports eight 10/100Base-TX Power over Ethernet (POE) ports (ports 1 to 8). Each port complies with the IEEE 802.3at and IEEE 802.3af stan- dards, and feature the ability to automatically enable/disable power when PoE-capa- ble devices are connected or removed.
  • Page 29 If the power input is less than what is required, to prevent exceeding the power bud- get, port priorities can be set via the RUGGEDCOM RS900GP operating system to dis- able low priority ports when demand is too high. Ports can also be enabled/disabled and placed on a power schedule to conserve power.
  • Page 30: Fiber Optic Ethernet Ports

    Description Green (Solid) Link established Green (Blinking) Link activity No link detected Link/Activity LED Figure 4.10 LED for Fiber Optic Ethernet Ports Specifications For further specifications, refer to "Fiber Optic Ethernet Port Specifications (Page 24)". RUGGEDCOM RS900GP Installation Manual, 06/2020, C79000-G8976-1026-07...
  • Page 31: Sfp Transceivers

    Communication Ports 4.4 SFP Transceivers SFP Transceivers The RUGGEDCOM RS900GP supports up to two Small Form-Factor Pluggable (SFP) transceiver sockets, which are compatible with a wide array of SFP transceivers avail- able from Siemens. LEDs Each socket features an LED that indicates its link state.
  • Page 32: Technical Specifications

    15 W 273 W (T) denotes time-delay fuse PoE Output Specifications The RUGGEDCOM RS900GP adheres to the following power output and IEEE 802.3 specifications depending on the input voltage supplied to the device. Power In Power Out 51 to 57 VDC 50 to 57 VDC, 30 W per Port Maximum (IEEE 302.at)
  • Page 33: Copper Ethernet Port Specifications

    5.4 Copper Ethernet Port Specifications Copper Ethernet Port Specifications The following details specifications for all standard and optional fixed copper Ether- net ports that can be ordered with the RUGGEDCOM RS900GP. For more information about the SFP ports, refer to "Copper Ethernet Ports (Page 17)".
  • Page 34: Operating Environment

    Maximum Altitude 2000 m (6562 ft) Measured from a 30 cm (12 in) radius surrounding the center of the RUGGEDCOM RS900GP enclosure. Operating temperature may vary based on the limitations of installed SFPs. Refer to the RUGGEDCOM SFP Transceivers Catalog for SFP temperature ratings.
  • Page 35: Dimension Drawings

    Technical Specifications 5.8 Dimension Drawings Dimension Drawings Note All dimensions are in millimeters, unless otherwise stated. 89.9 154.4 Figure 5.1 Overall Dimensions RUGGEDCOM RS900GP Installation Manual, 06/2020, C79000-G8976-1026-07...
  • Page 36 Technical Specifications 5.8 Dimension Drawings 44.5 38.1 156.9 26.0 64.1 Figure 5.2 Panel Mount Dimensions (Rear Mount Shown) RUGGEDCOM RS900GP Installation Manual, 06/2020, C79000-G8976-1026-07...
  • Page 37 Technical Specifications 5.8 Dimension Drawings 44.5 90.0 41.4 17.8 38.1 137.9   Figure 5.3 Panel Mount Dimensions (Side Mount Shown) RUGGEDCOM RS900GP Installation Manual, 06/2020, C79000-G8976-1026-07...
  • Page 38 Technical Specifications 5.8 Dimension Drawings 174.2 163.1 175.8 Figure 5.4 DIN Rail Mount Dimensions RUGGEDCOM RS900GP Installation Manual, 06/2020, C79000-G8976-1026-07...
  • Page 39 Technical Specifications 5.8 Dimension Drawings RUGGEDCOM RS900GP Installation Manual, 06/2020, C79000-G8976-1026-07...
  • Page 40: Certification

    Certification The RUGGEDCOM RS900GP device has been thoroughly tested to guarantee its con- formance with recognized standards and has received approval from recognized reg- ulatory agencies. Approvals This section details the standards to which the RUGGEDCOM RS900GP complies. 6.1.1 TÜV SÜD This device is certified by TÜV SÜD to meet the requirements of the following stan-...
  • Page 41: 6.1.3 Fcc

    Methods of Measurement The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens AG. For contact information, refer to "Contacting Siemens (Page vii)".
  • Page 42: Iso

    6.1.8 RoHS This device is declared by Siemens AG to meet the requirements of the following Ro- HS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: •...
  • Page 43: 6.1.9 Other Approvals

    • EN50121-4 Railway applications – Electromagnetic Compatibility – Emission and Immunity of the Signaling and Telecommunications Apparatus EMC and Environmental Type Tests The RUGGEDCOM RS900GP has passed the following Electromagnetic Compatibility (EMC) and environmental tests. EMC Type Tests Test Description...
  • Page 44 EMC Immunity Type Tests per IEEE 1613 Note The RUGGEDCOM RS900GP meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper Ports. Class 1 allows for temporary communica- tion loss, while Class 2 requires error-free and interrupted communications.
  • Page 45 °F), 16 Hours IEC 60068-2-2 Dry Heat Test Bd 85 °C (185   °F), 16 Hours IEC 60255-21-1 Vibration 2g @ 10-150 Hz Class 2 IEC 60255-21-2 Shock 30g @ 11 ms Class 2 RUGGEDCOM RS900GP Installation Manual, 06/2020, C79000-G8976-1026-07...
  • Page 46 Further Information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...

This manual is also suitable for:

Simatic net ruggedcom rs900gp

Table of Contents