hit counter script
Siemens RUGGEDCOM RS910W Installation Manual
Siemens RUGGEDCOM RS910W Installation Manual

Siemens RUGGEDCOM RS910W Installation Manual

Simatic net rugged ethernet switches
Hide thumbs Also See for RUGGEDCOM RS910W:

Advertisement

Quick Links

Installation Manual
SIMATIC NET
Rugged Ethernet Switches
RUGGEDCOM RS910W
Edition
02/2020
https://www.siemens.com

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RUGGEDCOM RS910W

  • Page 1 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RS910W Edition 02/2020 https://www.siemens.com...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM RS910W Communication Ports Technical Specifications Installation Manual Certification 02/2020 C79000-G8976-1031-09...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommend- ed or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Accessing Documentation ....................... v Disclaimer of Liability ......................v Registered Trademarks ......................v Training ..........................vi Customer Support ........................vi Contacting Siemens ....................... vii Introduction ........................... 1 Feature Highlights ....................2 Description ......................2 Required Tools and Materials ................. 4 Decommissioning and Disposal ................
  • Page 5 CSA ........................37 6.1.2 FCC ........................38 6.1.3 FDA/CDRH ......................38 6.1.4 ISED ........................38 6.1.5 TÜV SÜD ......................39 6.1.6 RoHS ........................39 6.1.7 Other Approvals ....................39 EMC and Environmental Type Tests ..............39 RUGGEDCOM RS910W Installation Manual, 02/2020, C79000-G8976-1031-09...
  • Page 6: Preface

    However, deviations between the product and the documentation may exist. Siemens shall not be liable for any errors or omissions contained herein or for conse- quential damages in connection with the furnishing, performance, or use of this ma- terial.
  • Page 7: Training

    Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
  • Page 8: Contacting Siemens

    Contacting Siemens Address Siemens AG Industry Sector 300 Applewood Crescent Concord, Ontario Canada, L4K 5C7 Telephone Toll-free: 1 888 264 0006 Tel: +1 905 856 5288 Fax: +1 905 856 1995 E-Mail ruggedcom.info.i-ia@siemens.com https://www.siemens.com RUGGEDCOM RS910W Installation Manual, 02/2020, C79000-G8976-1031-09...
  • Page 9 Preface Contacting Siemens viii RUGGEDCOM RS910W Installation Manual, 02/2020, C79000-G8976-1031-09...
  • Page 10: Introduction

    RUGGEDCOM RS910W to be placed in almost any location. The RUGGEDCOM RS910W can be mounted on a DIN rail or panel for efficient use of cabinet space. The integrated power supply supports a wide range of voltages (88-300 VDC or 85-264 VAC) for worldwide operability.
  • Page 11: Feature Highlights

    Terminal blocks for reliable maintenance free connections • CSA/UL 60950-1 safety approved to 85 °C (185 °F) Description The RUGGEDCOM RS910W features various ports, controls and indicator LEDs on the front panel for connecting, configuring and troubleshooting the device. RUGGEDCOM RS910W Installation Manual, 02/2020, C79000-G8976-1031-09...
  • Page 12 Device (Page 21)". Communication Ports Communication ports in general receive and transmit data, as well as provide access to the RUGGEDCOM RUGGEDCOM RS910W Web interface. For more information about the various ports available, refer to "Communication Ports (Page 23)".
  • Page 13: Required Tools And Materials

    Introduction 1.3 Required Tools and Materials Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RS910W: Tools/Materials Purpose AC power cord (16 AWG) For connecting power to the device. Multi-mode fiber optic cables For connecting the device to a LAN.
  • Page 14: Supported Fiber Optic Cables

    1000Base-SX 10GBase-SR OM1 (62.5/125) — 1300 2000 — — OM2 (50/125) — 1300 2000 — — OM3 (50/125) 1500 — 1300 2000 — — OM4 (50/125) 3500 — 1300 2000 — — Laser optimized. RUGGEDCOM RS910W Installation Manual, 02/2020, C79000-G8976-1031-09...
  • Page 15 Introduction 1.5.1 Supported Fiber Optic Cables RUGGEDCOM RS910W Installation Manual, 02/2020, C79000-G8976-1031-09...
  • Page 16: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 17: Installing The Device In Hazardous Locations

    If any item is missing or damaged, contact Siemens for assistance. Installing the Device in Hazardous Locations The RUGGEDCOM RS910W is designed to comply with the safety standards for Class I, Division 2 hazardous locations where concentrations of flammable gases, vapors or liquids may be present, as opposed to normal operating environments.
  • Page 18: Mounting The Device

    2.3.1 Mounting the Device on a DIN Rail The RUGGEDCOM RS910W can be ordered with a DIN rail adapter preinstalled on the back of the chassis. Use the adapter to mount the device to a standard 35 mm (1.4 in) IEC/EN 60715 or TS35 DIN rail.
  • Page 19 Insert a flathead screwdriver into the slot of the sliding release and move it down. Push the device against the bottom of the DIN rail, then let go of the sliding re- lease to latch the device. RUGGEDCOM RS910W Installation Manual, 02/2020, C79000-G8976-1031-09...
  • Page 20: Mounting The Device To A Panel

    2.3.2 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RS910W can be equipped with panel adapters pre-installed on the top and bottom of the chassis. The adapters allow the device to be attached to a panel using screws.
  • Page 21: Connecting The Antennas

    Panel Mounting Secure the adapters to the panel with #6-32 screws. Connecting the Antennas The RUGGEDCOM RS910W supports two dipole antennas that can be rotated 360° around the connection point, and up to 90° at the joint for optimal positioning. Note The RUGGEDCOM RS910W is shipped with two 2.4 GHz dipole antennas.
  • Page 22: Connecting The Failsafe Alarm Relay

    Control of the failsafe relay output is configurable through RUGGEDCOM RS910W . One common application for this relay is to signal an alarm if a power failure oc- curs. For more information, refer to the RUGGEDCOM RS910W User Guide for the RUGGEDCOM RS910W.
  • Page 23: Connecting Power

    Common Normally Open Figure 2.5 Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM RS910W supports power input from a single high AC/DC or low DC power supply. IMPORTANT • For 110/230 VAC rated equipment, an appropriately rated AC circuit breaker must be installed.
  • Page 24: Connecting High Ac/Dc Power

    Note Torque all terminal connections to 0.6 N·m (5 lbf-in). Secure the power terminal block to the device. RUGGEDCOM RS910W Installation Manual, 02/2020, C79000-G8976-1031-09...
  • Page 25 Connect the positive wire from the power source to the positive/live (+/L) termi- nal on the terminal block. Positive/Live (+/L) Terminal Negative/Neutral (-/N) Terminal Surge Ground Terminal Braided Ground Cable Figure 2.6 Terminal Block Wiring RUGGEDCOM RS910W Installation Manual, 02/2020, C79000-G8976-1031-09...
  • Page 26: 2.6.2 Connecting Low Dc Power

    2.6.2 Connecting Low DC Power RUGGEDCOM RS910W's equipped with 24 or 48 V power supply inputs feature re- verse polarity protection and dual power supply inputs allowing the device to accept redundant connections to a single DC power supply.
  • Page 27 Negative Terminal Surge Ground Terminal Braided Ground Cable Figure 2.8 Terminal Block Wiring – Single DC Power Supply Inputs Connect the negative wire from the power source to the negative terminal on the terminal block. RUGGEDCOM RS910W Installation Manual, 02/2020, C79000-G8976-1031-09...
  • Page 28 Connect the ground wire from the power source to the chassis groun terminal on the terminal block. RUGGEDCOM RS910W Installation Manual, 02/2020, C79000-G8976-1031-09...
  • Page 29 Installing the Device 2.6.2 Connecting Low DC Power RUGGEDCOM RS910W Installation Manual, 02/2020, C79000-G8976-1031-09...
  • Page 30: Device Management

    This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RS910W console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM RS910W User Guide for the RUGGEDCOM RS910W.
  • Page 31: Configuring The Device

    Ethernet Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RS910W console and Web interfaces via the device's IP address. The factory default IP address for the RUGGEDCOM RS910W is https://- 192.168.0.1.
  • Page 32: Communication Ports

    Communication Ports The RUGGEDCOM RS910W can be equipped with various types of communication ports to enhance its abilities and performance. Ports 1 and 2 Ports 3 and 4 Port 9 Figure 4.1 Port Assignment Port Type 1 and 2 Serial Ports...
  • Page 33 RJ45 Ethernet Port Pin Config- Reserved (Do Not Connect) uration Transmit Data- Reserved (Do Not Connect) Reserved (Do Not Connect) Specifications For specifications on the available copper Ethernet ports, refer to "Copper Ethernet Port Specifications (Page 32)". RUGGEDCOM RS910W Installation Manual, 02/2020, C79000-G8976-1031-09...
  • Page 34: Fiber Optic Ethernet Ports

    "Fiber Optic Eth- ernet Port Specifications (Page 33)". Wireless Ethernet Ports The RUGGEDCOM RS910W supports an optional set of IEEE 802.11 compliant wire- less Ethernet ports for accessing a Wireless Local Area Network (WLAN). Depending RUGGEDCOM RS910W Installation Manual, 02/2020, C79000-G8976-1031-09...
  • Page 35: 4.3.1 Supported Wireless Standards

    40 mW (16 dBm) 802.11g 54 Mbps Data Rate Receiver Sensitivity At Radio 802.11b 11 Mb @ -88 dBm/With Antenna: 11 Mb @ -91 dBm At Radio 802.11g 54 Mb @ -74 dBm/With Antenna: 54 Mb @ -77 dBm RUGGEDCOM RS910W Installation Manual, 02/2020, C79000-G8976-1031-09...
  • Page 36: Channel Allocations For Ieee 802.11B/G

      Not supported in Japan for 802.11g mode. Serial Ports The RUGGEDCOM RS910W supports DB9, RJ45 and ST (Straight Tip) fiber serial ports, all of which can be run in RS232, RS485 or RS422 mode. Note On power-up, all serial ports default to RS485 mode. Each port can be individually set to RS232, RS485 or RS422 mode through RUGGEDCOM RS910W .
  • Page 37: 4.4.1 Serial Rs232/Rs485/Rs422 Db9 Ports

    Serial RS232/RS485/RS422 DB9 Ports The RS910W can be equipped with serial RS232/RS485/RS422 DB9 ports. Each port can be set individually through the RUGGEDCOM RS910W operating system to op- erate in RS232, RS485 or RS422 mode. For more information, refer to the RUGGED- COM RS910W User Guide for the RS910W.
  • Page 38: 4.4.3 Serial Rs232/Rs485/Rs422 Fiber Ports

    Serial RS232/RS485/RS422 Fiber Ports The RS910W can be equipped with serial RS232/RS485/RS422 fiber ports. Each port can be set individually through the RUGGEDCOM RS910W operating system to op- erate in RS232, RS485 or RS422 mode. For more information, refer to the RUGGED- COM RS910W User Guide for the RS910W.
  • Page 39 • The twisted pair should be terminated at each end of the chain. The following shows the recommended RS485 wiring. 120Ω 10nF 120Ω 10nF RUGGEDCOM RS910W Device Common (Isolated Ground) Negative Positive Shield to Earth (Connected At a Single Point) RS485 Devices (32 Total) Figure 4.11...
  • Page 40: Technical Specifications

    5.5 kVDC 10 W 10 VDC 36 VDC 3.15 A(T) 1.5 kVDC 10 W 37 VDC 72 VDC 3.15 A(T) 1.5 kVDC 10 W (T) denotes time-delay fuse. Power consumption may vary based on configuration. RUGGEDCOM RS910W Installation Manual, 02/2020, C79000-G8976-1031-09...
  • Page 41: Failsafe Alarm Relay Specifications

    ü ü IEEE 802.3z     1000Base-LX ü Copper Ethernet Port Specifications The following details the specifications for copper Ethernet ports that can be ordered with the RUGGEDCOM RS910W. Speed 10/100Base-TX Connector RJ45 Duplex FDX/HDX Cable Type > CAT 5...
  • Page 42: Fiber Optic Ethernet Port Specifications

    3 dBm. To convert from peak to average, subtract 3 dBm. • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. Serial Port Specifications The following details the specifications for serial ports that can be ordered with the RUGGEDCOM RS910W.
  • Page 43: Operating Environment

    Technical Specifications 5.7 Operating Environment Operating Environment The RUGGEDCOM RS910W is rated to operate under the following environmental conditions. Ambient Operating Tempera- -40 to 85 °C (-40 to 185 °F) ture Ambient Storage Temperature -40 to 85 °C (-40 to 185 °F)
  • Page 44 Technical Specifications 5.9 Dimension Drawings 65.3 116.59 7.87 Figure 5.1 Overall Dimensions RUGGEDCOM RS910W Installation Manual, 02/2020, C79000-G8976-1031-09...
  • Page 45 Technical Specifications 5.9 Dimension Drawings 132.9 13.64 101.6 11.2 78.74 120.65 Figure 5.2 Panel and DIN Rail Mount Dimensions RUGGEDCOM RS910W Installation Manual, 02/2020, C79000-G8976-1031-09...
  • Page 46: Certification

    Certification The RUGGEDCOM RS910W device has been thoroughly tested to guarantee its con- formance with recognized standards and has received approval from recognized reg- ulatory agencies. Approvals This section details the standards to which the RUGGEDCOM RS910W complies. 6.1.1 This device meets the requirements of the following Canadian Standards Association (CSA) standards under certificate 1550963: •...
  • Page 47: 6.1.2 Fcc

    Title 21 Code of Federal Regulations (CFR) – Chapter I – Sub-chapter J – Radiolog- ical Health 6.1.4 ISED This device is declared by Siemens AG to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) This device further complies with IC RSS-210 and is approved under the ID 4997A- VG5RW80G.
  • Page 48: Tüv Süd

    Information Technology Equipment – Safety – Part 1: General Requirements 6.1.6 RoHS This device is declared by Siemens AG to meet the requirements of the following Ro- HS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: •...
  • Page 49 Mode @ 1 MHz AC Pow- 2.5 kV Common er Ports Mode @ 1 MHz 1 kV Differential Mode @ 1 MHz Mains Frequency Voltage Signal Ports 30 V Continuous 61000-4-16 300 V for 1 s RUGGEDCOM RS910W Installation Manual, 02/2020, C79000-G8976-1031-09...
  • Page 50 EMC Immunity Type Tests per IEEE 1613 Note The RUGGEDCOM RS910W meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Class 1 allows for temporary communica- tion loss, while Class 2 requires error-free and interrupted communications.
  • Page 51 95% (Non-Con-   Heat, Cyclic) densing), 55 °C (131 °F), 6 Cycles IEC 60255-21-1 Vibration 2 g @ 10 to 150 Hz Class 2 IEC 60255-21-2 Shock 30 g @ 11 ms Class 2 RUGGEDCOM RS910W Installation Manual, 02/2020, C79000-G8976-1031-09...
  • Page 52 Further Information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...

Table of Contents