3.
Enable downstream (infrastructure to vehicle) Multicast traffic by
adding multicast route 224.5.5.6 / 5.255.255.255 to the global
gateway unit, and to the Mesh End unit in each subnet cluster.
7.7.6. SNMP configuration
The SNMP window can be used to configure an SNMP v2c or SNMP v3
service to run on the Cisco FM4500 Mobi.
Walk-throughs (no agent-to-manager notifications) and traps (agent-to-
manager notifications enabled) are both supported. If SNMP traps are
enabled, you can specify the server address to which monitoring
information must be sent.
IMPORTANT
The same SNMP configuration must be set for all Fluidmesh
units in the wireless network.
For
configuration, refer to the Fluidmesh SNMP FM-MIB OID Table
and MIB configuration files. These can be downloaded from
the Fluidmesh Partner Portal (Documentation section > User
Manuals > Advanced Manuals.)
To change the SNMP settings, do the following steps:
•
Click the -snmp mode link under ADVANCED SETTINGS in the
left-hand settings menu.
• The default SNMP dialog will be shown
106)).
© 2021 Cisco and/or its affiliates. All rights reserved.
Device configuration using the configurator interface
IMPORTANT
If TITAN is enabled at core network level and dual-
redundant global gateway units are installed, do not
enter the global gateway's actual Mesh ID number as
the Destination Address. Instead, use Destination
Address 5.0.0.0
NOTE
5.255.255.255 is the wildcard address for all Mesh ID
destinations within the network.
detailed
information
on
Fluidmesh
unit
SNMP
(Figure 41 (page