LEDs
LED
SYSTEM
ACTIVE
PWR MGMT
LINK
ACT
MGMT ETH
Note
LOG FLASH
OL-30452-01.
Color
Status
All chassis environmental monitors are reporting okay.
Green
Amber
Indicates one of the following:
Red
Indicates one of the following:
The supervisor module is operational and active.
Green
Amber
The supervisor module is in standby mode.
Green
Sufficient power is available for all installed modules.
Amber
Sufficient power is not available for all installed modules.
Green
The module has detected a link.
Off
The module does not detect a link.
Flashing green
The module is transmitting or receiving.
Off
The module is not transmitting or receiving.
Green
The management port is operational.
This is
Amber
The management port link has been disabled through the software.
available only
on
Flashing
The management port link is bad and has been disabled due to a
Supervisor-2E
amber
hardware failure.
modules.
Off
The module has not detected a signal.
Green
The log flash CompactFlash or USB disk is being accessed. Do not
remove the media until the LED is off.
Off
The expansion flash CompactFlash or USB disk is not being accessed.
You can remove the media while this LED is off.
Cisco Nexus 7710 Switch Site Preparation and Hardware Installation Guide
• At least one power supply has failed or the power supply fan has
failed.
• Incompatible power supplies are installed.
• At least one redundant fan or fan controller has failed in the
chassis. Overheating is not imminent.
• The temperature of the Supervisor engine has exceeded the major
threshold level.
• At least one non-redundant fan or fan controller, or both redundant,
have failed in the chassis. Overheating is imminent.