APPENDIX 3 FIRMWARE SWITCHS (WSW)
Selector
No.
1
2
3
4
5
|
8
NOTE:
•
•
l
Selectors 1 and 2: Monitoring the PC ON/OFF state
For the related functions, refer to WSW36, selectors 2 and 3.
l
Selectors 3: Parallel port output pins kept at high level
Setting this selector to "0" will keep all parallel output pins of the facsimile equipment at high
level. Use this setting if Resource Manager (bundled with MFC models) installed to Windows
NT running on the connected PC fails to monitor the power ON/OFF state of the facsimile
equipment.
Selector
No.
1
|
7
8
WSW46 (Monitor of PC ON/OFF state)
Function
Monitoring the PC ON/OFF state
Parallel port output pins kept at high
level
Scanned garbage correction
processing
Not used.
Selector 3 is applicable only to models equipped with a parallel interface.
Selectors 6 through 8 are applicable only to models equipped with a flat-bed scanner.
WSW47 (Function setting 22)
Function
Not used.
Switching of USB High/Full Speed
Setting and Specifications
No. 1 2
0 0 :
0 1 :
1 0 :
1 1 :
0:
Enabled
0:
ON
Setting and Specifications
0:
Auto (Automatic switching)
1:
Full speed is set.
A-48
Disabled
Monitor SELECT IN
Monitor STROBE
Monitor both SELECT IN and
STROBE
1:
Disabled
1:
OFF