hit counter script
KitchenAid 30" Installation Instructions And Use & Care Manual
KitchenAid 30" Installation Instructions And Use & Care Manual

KitchenAid 30" Installation Instructions And Use & Care Manual

30" (76.2 cm) and 36" (91.4 cm) retractable (pop-up) downdraft vent system
Table of Contents

Advertisement

Available languages

Available languages

30" (76.2 CM) AND 36" (91.4 CM)
RETRACTABLE (POP-UP) DOWNDRAFT VENT
SYSTEM
Installation Instructions and Use & Care Guide
For questions about features, operation/performance, parts, accessories or service, call: 1-800-422-1230
In Canada, for assistance, installation and service, call: 1-800-807-6777
or visit our website at...
www.kitchenaid.com or www.KitchenAid.ca
SYSTÈME DE VENTILATION RÉTRACTABLE
(CLAPET) DE 30" (76,2 CM) ET 36" (91,4 CM)—
ASPIRATION PART LE BAS
Instructions d'installation et Guide d'utilisation et d'entretien
Au Canada, pour assistance, installation ou service composez le 1-800-807-6777
ou visitez notre site web à...
www.KitchenAid.ca
Table of Contents/Table des matières............................................................................. 2
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONLY.
IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS.
POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT.
LI3ZTB/W10342489E

Advertisement

Table of Contents
loading

Summary of Contents for KitchenAid 30"

  • Page 1 For questions about features, operation/performance, parts, accessories or service, call: 1-800-422-1230 In Canada, for assistance, installation and service, call: 1-800-807-6777 or visit our website at... www.kitchenaid.com or www.KitchenAid.ca SYSTÈME DE VENTILATION RÉTRACTABLE (CLAPET) DE 30" (76,2 CM) ET 36" (91,4 CM)—...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS VENT SYSTEM SAFETY..............3 Install Downdraft Vent In-Line (External Type) Blower Motor.............18 INSTALLATION REQUIREMENTS ..........5 Make Electrical Connections Tools and Parts ................5 for In-Line Blower Motor System ..........20 Location Requirements..............5 Make Electrical Power Supply Connection Electrical Requirements ...............8 to Downdraft Vent ..............21 Venting Requirements..............8 Check Operation ................22...
  • Page 3: Vent System Safety

    VENT SYSTEM SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
  • Page 4: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF A RANGE TOP WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC GREASE FIRE: SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may Use this unit only in the manner intended by the ignite.
  • Page 5: Installation Requirements

    INSTALLATION REQUIREMENTS Tools and Parts Location Requirements Gather the required tools and parts before starting installation. NOTE: Downdraft vent is installed directly behind the cooktop. Read and follow the instructions provided with any tools listed Install the downdraft vent first, then install the cooktop. here.
  • Page 6: Product Dimensions

    Product Dimensions Models with interior-mounted blower motor Models with exterior-mounted blower motor Top trim widths: 30" (76.2 cm) 4³⁄₄" (12.1 cm) 36" (91.4 cm) 13¹⁄₂" (34.3 cm) retractable vent height 13¹⁄₈" (33.4 cm) 1¹⁄₂" (3.8 cm) 6⁹⁄₁₆" (16.7 cm) ³⁄₈" (0.95 cm) 27"...
  • Page 7 Cabinet Dimensions Interior-mounted blower motor model Exterior-mounted blower motor model 10" (25.4 cm) ¹⁄₂" (12.7 mm) minimum A= ¹⁄₂" (12.7 mm) minimum 21⁵⁄₁₆" (54.1 cm) 21⁵⁄₁₆" (54.1 cm) Cutouts are for 3¹⁄₄" x 10" (8.3 x 25.4 cm) Locate power rectangular or 6"...
  • Page 8: Electrical Requirements

    Countertop Cutout Dimensions Chart A. ½" (12.7 mm) minimum to backsplash or rear wall ³⁄₄ " (19.1 mm) maximum backsplash depth ¹⁄₂ ¹⁄₂ C. 27 " (69.9 cm) on 30" (76.2 cm) models 33 " (85.9 cm) on 36" (91.4 cm) models ¹³⁄₁₆...
  • Page 9: Installation Instructions Interior-Mounted Vent Motor

    INSTALLATION INSTRUCTIONS INTERIOR-MOUNTED VENT MOTOR Venting Methods Island Location—Vent System Installed Under a Concrete Determine which venting method is best for your application. Vent system can terminate either through the wall or floor. Slab Using PVC Sewer Pipe Island Location Front (Standard)-Mounted Blower Motor Front (Standard)-Mounted Rear-Mounted Blower...
  • Page 10 Calculating Vent System Length 3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 4.5 ft to 6" (15.2 cm) transition (1.4 m) 3¼" x 10" (8.3 x 25.4 cm) rectangular vent is required from the blower motor box. It can be transitioned to 6" (15.2 cm) round vent if needed.
  • Page 11: Install Vent System

    Install Vent System 6. Measure distance “X” from the cabinet floor to the top of the WARNING countertop. Subtract 28¹⁄₂" from distance “X” to determine dimension “Y” (X - 28¹⁄₂ = Y). Excessive Weight Hazard Top of countertop Use two or more people to move and install downdraft vent.
  • Page 12: Rear Mounting-Blower Motor

    Bottom Venting: Rear Mounting—Blower Motor NOTE: If installing the vent damper in the down position, a wall or roof cap with a damper at the exit end of the vent system is NOTE: Optional blower motor rear mounting position (opposite required.
  • Page 13: Complete Installation (Interior-Mounted Motor)

    5. Remove the screws from the wire mounting plate. Complete Installation (Interior-Mounted Motor) NOTE: The downdraft vent system is supplied with a 3¹⁄₄" x 10" (8.3 x 25.4 cm) back draft damper and a 6" (15.2 cm) round vent transition with damper. Refer to “3¹⁄₄" x 10" (8.3 x 25.4 cm) back draft damper”...
  • Page 14 2. Remove 4 screws attaching the terminal box cover. 5. Drill 2 pilot holes through each of the undercounter mounting brackets into the underside of the countertop. Using 2 screws (not provided) of the appropriate length, mount the brackets to the countertop. IMPORTANT: Select a screw length that will not allow the screws to go through the countertop when tightened.
  • Page 15: Make Electrical Connections

    Make Electrical Connections Check Operation 1. Push and hold the button on the top of the downdraft vent for WARNING a few seconds. The retractable section of the downdraft vent will rise, and the blower will start. Position the top trim over the retractable section and snap trim into place.
  • Page 16: Installation Instructions Exterior-Mounted Vent Motor

    INSTALLATION INSTRUCTIONS EXTERIOR-MOUNTED VENT MOTOR CAUTION: To reduce the risk of fire and electrical shock, NOTE: Exterior-mounted vent motor installations require an install the downdraft only with remote blower systems that approved in-line blower motor system. Model numbers are sold by Whirlpool Corporation. Model numbers UXI0600DYS (600 cfm) and UXI1200DYS (1200 cfm) are available UXI0600DYS (600 cfm) and UXI01200DYS (1200 cfm).
  • Page 17: Install Vent System

    Install Vent System 6. Measure distance “X” from the cabinet floor to the top of the WARNING countertop. Subtract 28¹⁄₂" from distance “X” to determine dimension “Y” (X - 28¹⁄₂" = Y). Excessive Weight Hazard Top of countertop Use two or more people to move and install downdraft vent.
  • Page 18: Complete Installation (Exterior-Mounted Motor)

    4. Drill 2 pilot holes through each of the undercounter mounting brackets into the underside of the countertop. Using 2 screws Complete Installation (not provided) of the appropriate length, mount the brackets (Exterior-Mounted Motor) to the countertop. 1. Remove 4 screws attaching the terminal box cover. IMPORTANT: Select a screw length that will not allow the screws to go through the countertop when tightened.
  • Page 19 Prepare the In-line Blower System Install In-line Blower System NOTE: The blower motor housing can be mounted using 4 holes from either the inlet side or the outlet side of the blower. WARNING Outlet Side Excessive Weight Hazard Use two or more people to move and install in-line blower motor system.
  • Page 20: Make Electrical Connections For In-Line Blower Motor System

    4. Locate the electrical terminal boxes in the in-line blower housing and downdraft vent. Remove the terminal box covers Make Electrical Connections for In-Line and set the covers and screws aside. Blower Motor System WARNING Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating.
  • Page 21: Make Electrical Power Supply Connection To Downdraft Vent

    7. Use UL listed wire connectors and connect the gray wires (G) together. Make Electrical Power Supply Connection to Downdraft Vent WARNING WARNING Electrical Shock Hazard Electrically ground blower. Electrical Shock Hazard Connect ground wire to green and yellow ground wire Disconnect power before servicing.
  • Page 22: Check Operation

    4. Use UL listed wire connectors and connect white wires (B) together. Check Operation 1. Push and hold the button on the top of the downdraft vent for WARNING a few seconds. The retractable section of the downdraft vent will rise, and the blower will start. Position the top trim over the retractable section and snap trim into place.
  • Page 23: Vent System Use

    VENT SYSTEM USE The retractable downdraft vent system is designed to remove smoke, cooking vapors and odors from the cooktop area. Operating Downdraft Vent For best results, the vent should be operating before cooking To Use: is started. 1. Push and hold the button on top of downdraft vent for a few If you use large or tall utensils, place them on the large rear seconds.
  • Page 24: Vent System Care

    VENT SYSTEM CARE Surface of Downdraft Vent Filters To avoid damaging the finish, clean downdraft vent with soap Frequently remove and clean the filter(s) in the retractable section and water. Do not use scouring powder or abrasive solutions. of the downdraft vent. This will improve the operating efficiency of the downdraft vent system.
  • Page 25: Wiring Diagrams

    WIRING DIAGRAMS Interior-Mounted Blower Motor Motor Specifications Power supply 120 VAC Frequency 60 Hz Wattage rating 420 W Amperage 3.7 A Motor Resistance BU/W 21.6 Ohms BU/R 18 Ohms BU/GY 14.3 Ohms BU/BK 9.8 Ohms Blower Switch Operation Function Contact 1 - 3 N.O.
  • Page 26: Exterior-Mounted Blower Motor

    Exterior-Mounted Blower Motor NOTE: Wiring for external blower motor SEL0016521 Motor Specifications Power supply 120 VAC Frequency 60 Hz Wattage rating 420 W Amperage 3.7 A N.O. Motor Resistance N.C. BU/W 21.6 Ohms BU/R 18 Ohms BU/GY 14.3 Ohms BU/BK 9.8 Ohms N.O.
  • Page 27: Assistance Or Service

    For Model Series KXD4636 and KXD4736 For further assistance 36" (91.4 cm) One-Piece Top Trim If you need further assistance, you can write to KitchenAid with Order Part Number W10387675 (black) any questions or concerns at: Order Part Number W10388170 (white)
  • Page 28: Warranty

    KitchenAid brand of Whirlpool Corporation or Whirlpool Canada LP (hereafter “KitchenAid”) will pay for Factory Specified Parts and repair labor to correct defects in materials or workmanship. Service must be provided by a KitchenAid designated service company. This limited warranty is valid only in the United States or Canada and applies only when the major appliance is used in the country in which it was purchased.
  • Page 29: Sécurité Du Système De Ventilation

    SÉCURITÉ DU SYSTÈME DE VENTILATION Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole d’alerte de sécurité.
  • Page 30 IMPORTANTES INSTRUCTIONS DE SÉCURITÉ AVERTISSEMENT : POUR MINIMISER LE RISQUE AVERTISSEMENT : POUR RÉDUIRE LE RISQUE D'UN FEU DE GRAISSE SUR LA CUISINIÈRE : D'INCENDIE, CHOC ÉLECTRIQUE OU DOMMAGES CORPORELS, RESPECTER LES INSTRUCTIONS Ne jamais laisser un élément de surface fonctionner à SUIVANTES : puissance de chauffage maximale sans surveillance.
  • Page 31: Exigences D'installation

    EXIGENCES D'INSTALLATION Outils et pièces Exigences d'emplacement Rassembler les outils et pièces nécessaires avant d’entreprendre REMARQUE : Le système d'extraction par le bas est installé l’installation. Lire et observer les instructions fournies avec directement derrière la table de cuisson. Installer d’abord le chacun des outils de la liste ci-dessous.
  • Page 32 Dimensions du produit Modèles à ventilateur monté à l'intérieur Modèles à ventilateur monté à l'extérieur Largeurs de la garniture supérieure : 30" (76,2 cm) 4³⁄₄" (12,1 cm) 36" (91,4 cm) 13¹⁄₂" (34,3 cm) hauteur de l’évacuation rétractable 13¹⁄₈" (33,4 cm) 1¹⁄₂"...
  • Page 33 Dimensions du placard Modèle avec ventilateur monté à l’intérieur Modèle avec ventilateur monté à l'extérieur 10" (25,4 cm) ¹⁄₂" (12,7 mm) A= ¹⁄₂" (12,7 mm) minimum minimum 21⁵⁄₁₆" (54,1 cm) 21⁵⁄₁₆" (54,1 cm) Les découpes correspondent à un circuit d’évacuation rectangulaire de 3¹⁄₄"...
  • Page 34 Plan de travail – Dimensions des ouvertures à découper IMPORTANT : Les plans de travail avec rebord avant arrondi ne sont pas recommandés pour ces installations. Certains modèles nécessitent un plan de travail de plus de 25" (63,5 cm); voir le tableau des dimensions de l'ouverture du plan de travail.
  • Page 35: Spécifications Électriques

    Spécifications électriques Exigences concernant l’évacuation Observer les dispositions de tous les codes et règlements en IMPORTANT : Avant d’effectuer des découpes, s’assurer qu’il y vigueur. a un dégagement convenable dans le mur ou le plancher pour le système d’extraction. S'assurer que l’installation électrique est correcte et qu'elle satisfait aux exigences de la plus récente édition de la norme Utiliser un conduit métallique rigide.
  • Page 36: Instructions D'installation

    INSTRUCTIONS D’INSTALLATION VENTILATEUR MONTÉ À L’INTÉRIEUR Méthodes d’évacuation Configuration en îlot—Circuit d’évacuation installé sous Déterminer la méthode d’évacuation la plus appropriée. La sortie à l’extérieur du circuit d’évacuation peut se faire à travers le une dalle de béton (utilisation de conduit de PVC pour plancher ou à...
  • Page 37: Installation Du Conduit D'évacuation

    Pour calculer la longueur effective du circuit d’évacuation Exemple de circuit d’évacuation nécessaire, additionner les longueurs équivalentes (en pieds ou mètres) de tous les composants utilisés dans le circuit. 6 pi Rectangulaire de 3¹⁄₄" x 10" (1,8 m) Composant (8,3 cm x 25,4 cm) 2 pi (0,6 m) Raccord coudé...
  • Page 38 4. Installer sur la caisse du système d’extraction les équerres 7. Fixer les pieds de soutien aux côtés de la caisse du système droite et gauche de montage sous le plan de travail. Insérer d’extraction avec 4 vis de 4 x 8 mm pour chacun. Les régler à les encoches en trou de serrure dans les languettes guides et la distance “Y”...
  • Page 39: Montage Du Ventilateur À L'arrière

    Sortie par le côté gauche ou le côté droit : Montage du ventilateur à l’arrière 1. À deux personnes ou plus, poser l’arrière du système d’extraction par le bas face au sol. REMARQUE : Position de montage du ventilateur à l’arrière (côté 2.
  • Page 40: Achever L'installation

    5. Retirer les vis de la platine de montage du câble. Achever l’installation (Ventilateur monté à l’intérieur) REMARQUE : Le système d’extraction par le bas est livré avec un clapet anti-retour de 3¹⁄₄" x 10" (8,3 x 25,4 cm) et un raccord de transition pour conduit rond de 6"...
  • Page 41: Raccordements Électriques

    2. Ôter les 4 vis du couvercle du boîtier de connexion. 5. Percer 2 avant-trous à travers les équerres de fixation sous le plan de travail, dans la face inférieure du plan de travail. Avec 2 vis (non fournies) de la longueur adéquate, fixer les équerres au plan de travail.
  • Page 42: Contrôle Du Fonctionnement

    2. Faire passer le câble d’alimentation à travers le connecteur de conduit et dans le boîtier de connexion. Contrôle du fonctionnement 1. Appuyer pendant quelques secondes sur le bouton au AVERTISSEMENT sommet du système d’extraction par le bas. La partie rétractable du système d’extraction par le bas se lève, et le ventilateur se met en marche.
  • Page 43: Instructions D'installation

    INSTRUCTIONS D’INSTALLATION VENTILATEUR MONTÉ À L’EXTÉRIEUR MISE EN GARDE : Afin de réduire le risque d’incendie ou de REMARQUE : L’installation d’un ventilateur monté à l’extérieur choc électrique, installer ce système d’extraction par le bas nécessite un système de ventilation en ligne approuvé. Les uniquement avec des ventilateurs installés à...
  • Page 44: Installation Du Conduit D'évacuation

    Installation du conduit d’évacuation 6. Mesurer la distance “X” entre le sol et le dessus du plan de AVERTISSEMENT travail. Soustraire 28¹⁄₂" de la distance “X” pour déterminer la distance “Y” (X - 28¹⁄₂" = Y). Risque du poids excessif Dessus du plan de travail Utiliser deux ou plus de personnes pour déplacer et installer le système d’extraction.
  • Page 45: Achever L'installation (Ventilateur Monté À L'extérieur)

    4. Percer 2 avant-trous à travers les équerres de fixation sous le plan de travail, dans la face inférieure du plan de travail. Avec Achever l’installation 2 vis (non fournies) de la longueur adéquate, fixer les (Ventilateur monté à l’extérieur) équerres au plan de travail.
  • Page 46 Préparation du système de ventilation en ligne Installation du système de ventilation en ligne REMARQUE : Le logement du ventilateur peut être monté en utilisant les 4 trous du côté de l'entrée ou de la sortie du AVERTISSEMENT ventilateur. Risque du poids excessif Côté...
  • Page 47: Raccordements Électriques Du Système De Ventilation En Ligne

    4. Situer les boîtiers de connexion électrique dans la caisse du ventilateur en ligne et le système d’extraction par le bas. Raccordements électriques du système de Retirer le couvercle des boîtiers de connexion et mettre de ventilation en ligne côté les couvercles et les vis. AVERTISSEMENT Risque de choc électrique Déconnecter la source de courant électrique avant...
  • Page 48: Raccordement De L'alimentation Électrique Au Système D'extraction Par Le Bas

    7. Raccorder les conducteurs gris (G) à l’aide de connecteurs 3. Raccorder les conducteurs de couleurs correspondantes de fils homologués UL. (noir et noir, blanc et blanc, etc.) à l’aide de connecteurs de fils homologués UL. REMARQUE : Raccorder le conducteur de terre vert (ou vert/ AVERTISSEMENT jaune) du conduit de câblage au conducteur de terre vert (ou nu) de l’alimentation électrique domestique à...
  • Page 49: Contrôle Du Fonctionnement

    2. Situer le boîtier de connexion du système d’extraction par le 5. À l’aide des connecteurs de fils (homologation UL), connecter bas. le conducteur de terre vert (ou nu) du câble d’alimentation du domicile aux conducteurs de terre vert/jaune (A) du boîtier de connexion.
  • Page 50: Utilisation Du Système D'extraction

    UTILISATION DU SYSTÈME D’EXTRACTION Le système d’extraction par le bas rétractable sert à éliminer la fumée, les vapeurs de cuisson et les odeurs issues de la table de Utilisation du système d’extraction par le bas cuisson. Utilisation : Pour de meilleurs résultats, le système d’extraction doit être 1.
  • Page 51: Entretien Du Système D'évacuation

    ENTRETIEN DU SYSTÈME D’ÉVACUATION Surface du système d’extraction par le bas Filtres Pour éviter d’endommager la finition, nettoyer les surfaces avec Enlever et nettoyer fréquemment le(s) filtre(s) de la section de l’eau savonneuse. Ne pas utiliser une solution de récurage ou rétractable du système d’extraction par le bas.
  • Page 52: Schéma De Câblage

    SCHÉMA DE CÂBLAGE Ventilateur monté à l'intérieur Caractéristiques du moteur Alimentation 120 VCA JA/VE Fréquence 60 Hz Puissance nominale 420 W Intensité 3,7 A Résistance du moteur BU/BL 21,6 ohms BU/R 18 ohms BU/GRIS 14,3 ohms BU/N 9,8 ohms GRIS GRIS Fonctionnement du commutateur du ventilateur...
  • Page 53: Ventilateur Monté À L'extérieur

    Ventilateur monté à l'extérieur REMARQUE : Câblage pour ventilateur à l'extérieur SEL0016521 GRIS GRIS Caractéristiques du moteur Alimentation 120 VCA Fréquence 60 Hz Puissance nominale 420 W Intensité 3,7 A N.O. Résistance du moteur N.F. BU/BL 21,6 ohms GRIS GRIS BU/R 18 ohms BU/GRIS...
  • Page 54: Assistance Ou Service

    Veuillez appeler sans frais le Centre pour l'eXpérience de la service après la garantie, partout au Canada. clientèle de KitchenAid au : 1-800-422-1230 ou visitez notre site web à www.kitchenaid.com. Pour plus d’assistance Nos consultants sont prêts à...
  • Page 55: Garantie

    5. Les défauts apparents, notamment les éraflures, les bosses, fissures ou tout autre dommage au fini du gros appareil ménager, à moins que ces dommages soient dus à des vices de matériaux ou de fabrication et soient signalés à KitchenAid dans les 30 jours suivant la date d’achat.
  • Page 56 10/12 ® /™ ©2012 KitchenAid. Used under license in Canada. All rights reserved. Printed in Mexico W10342489E Utilisée sous licence au Canada. Tous droits réservés. Imprimé au Mexique...

This manual is also suitable for:

36"

Table of Contents