Smartports Macro Configuration Guidelines

Follow these guidelines when configuring macros on your switch:
There are Cisco-default Smartports macros embedded in the switch software (see
display these macros and the commands they contain by using the show parser macro user EXEC
command.
OL-8915-03
When creating a macro, do not use the exit or end commands or change the command mode by using
interface interface-id. This could cause commands that follow exit, end, or interface interface-id
to execute in a different command mode.
When creating a macro, all CLI commands should be in the same configuration mode.
When creating a macro that requires the assignment of unique values, use the parameter value
keywords to designate values specific to the interface. Keyword matching is case sensitive. All
matching occurrences of the keyword are replaced with the corresponding value. Any full match of
a keyword, even if it is part of a larger string, is considered a match and is replaced by the
corresponding value.
Macro names are case sensitive. For example, the commands macro name Sample-Macro and
macro name sample-macro will result in two separate macros.
Some macros might contain keywords that require a parameter value. You can use the macro global
apply macro-name ? global configuration command or the macro apply macro-name ? interface
configuration command to display a list of any required values in the macro. If you apply a macro
without entering the keyword values, the commands are invalid and are not applied.
When a macro is applied globally to a switch or to a switch interface, all existing configuration on
the interface is retained. This is helpful when applying an incremental configuration.
If you modify a macro definition by adding or deleting commands, the changes are not reflected on
the interface where the original macro was applied. You need to reapply the updated macro on the
interface to apply the new or changed commands.
You can use the macro global trace macro-name global configuration command or the macro trace
macro-name interface configuration command to apply and debug a macro to find any syntax or
configuration errors. If a command fails because of a syntax error or a configuration error, the macro
continues to apply the remaining commands.
Some CLI commands are specific to certain interface types. If a macro is applied to an interface that
does not accept the configuration, the macro will fail the syntax check or the configuration check,
and the switch will return an error message.
Applying a macro to an interface range is the same as applying a macro to a single interface. When
you use an interface range, the macro is applied sequentially to each interface within the range. If a
macro command fails on one interface, it is still applied to the remaining interfaces.
When you apply a macro to a switch or a switch interface, the macro name is automatically added
to the switch or interface. You can display the applied commands and macro names by using the
show running-config user EXEC command.
Cisco Catalyst Blade Switch 3020 for HP Software Configuration Guide