Configuring Enhanced Object Tracking
Command
Step 6
standby [group-number] track
object-number [decrement
[priority-decrement]]
Step 7
end
Step 8
show standby
Step 9
copy running-config startup-config (Optional) Save your entries in the configuration file.

Configuring Other Tracking Characteristics

You can also use the enhanced object tracking for tracking other characteristics.
Use the show track privileged EXEC command to verify enhanced object tracking configuration.
For more information about enhanced object tracking and the commands used to configure it, see this
URL:
http://www.cisco.com/en/US/products/sw/iosswrel/ps1839/products_feature_guide09186a00801541be.
html

Monitoring Enhanced Object Tracking

Use the privileged EXEC or User EXEC commands in
information.
Table 38-2
Command
show track [object-number]
show track brief
Cisco Catalyst Blade Switch 3020 for HP Software Configuration Guide
38-18
Purpose
Configure HSRP to track an object and change the hot standby priority based
on the state of the object.
Return to privileged EXEC mode.
Verify the standby router IP address and tracking states.
You can track the reachability of an IP route by using the track ip route reachability global
configuration command.
You can use the track ip route metric threshold global configuration command to determine if a
route is above or below threshold.
You can use the track resolution global configuration command to change the metric resolution
default values for routing protocols.
You can use the track timer tracking configuration command to configure the tracking process to
periodically poll tracked objects.
Commands for Displaying Tracking Information
Chapter 38
(Optional) group-number—The group number to which the tracking
applies.
object-number—Number representing the object to be tracked. The
range is from 1 to 500; the default is 1.
(Optional) decrement priority-decrement—Amount by which the hot
standby priority for the router is decremented (or incremented) when the
tracked object goes down (or comes back up). The range is from 1 to
255; the default is 10.
Table 38-2
Purpose
Display information about the all tracking lists or
the specified list.
Display a single line of tracking information
output.
Configuring HSRP and Enhanced Object Tracking
to display enhanced object tracking
OL-8915-03

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 3020

Table of Contents