Replace the DC power supply within five minutes or the system will shutdown.
Step 7
You have completed the procedure for removing a DC power supply from the Cisco ASR 1002-F Router.
Installing the DC Power Supply
This section provides information about replacing a DC power supply in the Cisco ASR 1002-F Router.
The color coding of the DC-input power supply leads depends on the color coding of the DC power source at your site.
Note
Typically, green or green/yellow is used for ground. Make certain the lead color coding you choose for the DC-input
power supply matches lead color coding used at the DC power source.
Figure 20
Cisco ASR 1002-F Router Terminal Block
1
Negative lead
Positive lead
2
Warning
Never install an AC power module and a DC power module in the same chassis. Statement 1050
Warning
Installation of the equipment must comply with local and national electrical codes. Statement 1074
Step 1
At the rear of the router, check that the power supply Standby switch is in the Standby position.
Step 2
Ensure that the negative and positive leads are disconnected from the site power source and the circuit breaker is turned
off.
Insert a DC power supply in power supply slot 0 or power supply slot 1 until it is full seated.
Step 3
Using a wire stripper, strip approximately 0.55 inch (14 mm) from the negative, positive, and ground lead.
Step 4