hit counter script
Siemens SIMATIC NET SCALANCE XCM-100 Operating Instructions Manual

Siemens SIMATIC NET SCALANCE XCM-100 Operating Instructions Manual

Hide thumbs Also See for SIMATIC NET SCALANCE XCM-100:

Advertisement

Quick Links

SIMATIC NET
Network components
SCALANCE XCM-100 Media
Converter
Operating Instructions
07/2022
C79000-G8976-C659-01
Introduction
Safety instructions
Recommendations on
network security
Network topologies
Device description
Installation and
disassembly
Connecting
Maintenance and cleaning
Technical specifications
Dimension drawings
Approvals
1
2
3
4
5
6
7
8
9
10
11

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET SCALANCE XCM-100

  • Page 1 Introduction Safety instructions Recommendations on network security SIMATIC NET Network topologies Network components SCALANCE XCM-100 Media Device description Converter Installation and disassembly Operating Instructions Connecting Maintenance and cleaning Technical specifications Dimension drawings Approvals 07/2022 C79000-G8976-C659-01...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Introduction ............................5 Designations used........................ 5 Trademarks.......................... 5 SIMATIC NET glossary......................5 Security information ......................6 Recycling and disposal ......................6 Electrostatic discharge ......................7 Safety instructions ..........................9 Recommendations on network security ....................11 Network topologies ..........................13 Network topologies with SCALANCE XCM-100..............
  • Page 4 Table of contents Safety instructions for operation with a power supply according to SELV ......38 Safety instructions on use in hazardous areas ..............39 Additional notes......................... 41 Wiring rules ........................42 Power supply 24 V AC / 24 V DC and grounding ..............43 Signaling contact .......................
  • Page 5: Introduction

    SCALANCE XCM102 used. Trademarks The following and possibly other names not identified by the registered trademark sign ® are registered trademarks of Siemens AG: • SCALANCE • SINEC SIMATIC NET glossary Explanations of many of the specialist terms used in this documentation can be found in the SIMATIC NET glossary.
  • Page 6: Security Information

    Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to cyber...
  • Page 7: Electrostatic Discharge

    Introduction 1.6 Electrostatic discharge Electrostatic discharge NOTICE Electrostatic sensitive devices (ESD) Electronic modules contain electrostatic sensitive components These components can easily be destroyed if handled incorrectly. Note the following instructions to avoid damage. • Touch electronic modules only when you absolutely need to work on them. •...
  • Page 8 Introduction 1.6 Electrostatic discharge SCALANCE XCM-100 Media Converter Operating Instructions, 07/2022, C79000-G8976-C659-01...
  • Page 9: Safety Instructions

    Safety instructions Read the safety notices Note the following safety notices. These relate to the entire working life of the device. You should also read the safety notices relating to handling in the individual sections, particularly in the sections "Installation" and "Connecting up". CAUTION To prevent injury and damage, read the manual before using the device.
  • Page 10 Safety instructions SCALANCE XCM-100 Media Converter Operating Instructions, 07/2022, C79000-G8976-C659-01...
  • Page 11: Recommendations On Network Security

    Recommendations on network security To prevent unauthorized access, note the following security recommendations. General • You should make regular checks to make sure that the device meets these recommendations and/or other security guidelines. • Evaluate your plant as a whole in terms of security. Use a cell protection concept with suitable products.
  • Page 12 Recommendations on network security SCALANCE XCM-100 Media Converter Operating Instructions, 07/2022, C79000-G8976-C659-01...
  • Page 13: Network Topologies

    Network topologies Network topologies with SCALANCE XCM-100 You can build the following topologies with the SCALANCE XCM-100 series media converters: • Line • Star • Redundant ring when two media converters are used The connection status (Link up or Link down) of the twisted pair ports always corresponds to the connection status of the SFP ports.
  • Page 14 Network topologies 4.1 Network topologies with SCALANCE XCM-100 Bus topology Figure 4-1 Line topology with electrical und optical cables and two SCALANCE XCM102 Star topology The following example shows an optical star topology. SCALANCE XCM102 media converters allow the connection of the devices with twisted pair cables. Figure 4-2 Optical star topology with SCALANCE XCM102 SCALANCE XCM-100 Media Converter...
  • Page 15 Network topologies 4.1 Network topologies with SCALANCE XCM-100 Ring Topology The following example shows an electrical ring with a SCALANCE XM408-4C as the redundancy manager. With two SCALANCE XCM102 media converters, part of the ring can be implemented with a fiber-optic cable. Note Replacement of SCALANCE X101-1 devices with SCALANCE XCM102 If you want to replace SCALANCE X101-1 or SCALANCE X101-1LD devices with SCALANCE...
  • Page 16: Coupling Of Network Segments

    Network topologies 4.2 Coupling of network segments Coupling of network segments The following example shows the redundant coupling ("stand-by coupling") of rings with two SCALANCE XCM102 media converters. This setup is only possible with redundancy-capable stations, in the example, SCALANCE XM408-4C. Figure 4-4 Coupling network segments with SCALANCE XCM102 media converters SCALANCE XCM-100 Media Converter...
  • Page 17: Device Description

    Device description Purpose The devices of the SCALANCE XCM-100 product group enable cost-effective setup of Industrial Ethernet networks with media transitions. The use of a SCALANCE XCM-100 Media Converter is especially recommended for the following tasks: • In a network with twisted pair cables, a connection is to be made with fiber-optic cables, but the device in question does not have an FO port.
  • Page 18: Scope Of Delivery

    Device description 5.4 Scope of delivery Properties SCALANCE XCM102 SNTP + SICLOCK Cut Through Scope of delivery The following parts are included in the scope of delivery of the SCALANCE XCM-100 Media Converter: • One SCALANCE XCM-100 Media Converter • One 2-pin plug-in terminal block (signaling contact) •...
  • Page 19: Device View

    Device description 5.5 Device view Device view The following figure shows an overview of the components of the SCALANCE XCM102: SCALANCE SIEMENS XCM102 SELECT/ ① LED display ② RJ45 port for twisted pair cable ③ SFP port for fiber-optic cable ④...
  • Page 20: Led Display

    Device description 5.6 LED display LED display The following figure shows the arrangement of the LEDs on the SCALANCE XCM-100. SCALANCE SIEMENS XCM102 SIEM SELECT/ LED "A" (red alarm LED) The "A" LED indicates an alarm status of the device.
  • Page 21: Select/Set Button

    Device description 5.7 SELECT/SET button LEDs "L" (green power LED) The power LED shows the status of the power supply. LED color LED status Meaning Green The power supply L1 or L2 is connected. Power supply L1 or L2 is not connected or the connected voltage is below 14 V DC. Note If none of the two power LEDs is on, all other LEDs are off as well.
  • Page 22: Accessories

    Device description 5.8 Accessories Phase Description This new status is adopted and stored as the new fault mask in phase 3. LEDs flashing If you release the SET button while the LEDs are still flashing, saving is aborted. LEDs lit If you release the SET button as soon as the LEDs light up, the current settings will be stored.
  • Page 23 Device description 5.8 Accessories Notes of selecting the plug-in transceiver. NOTICE Loss of approvals when operating with unsuitable SFPs The approvals granted for the device are only valid when operating with one of the SFPs listed below. The use of any other SFP invalidates the approvals. Only use the device with an SFP specified for this purpose.
  • Page 24 Device description 5.8 Accessories Pluggable transceiver SFP (1000 Mbps) Type Property Article number SFP992-1 1 x 1000 Mbps, LC port optical for glass FO cable 6GK5 992-1AL00-8AA0 (multimode), up to max. 750 m 10 packing unit (VPE 10) 6GK5 992-1AL00-8AC0 SFP992-1 (C) 1 x 1000 Mbps, LC port optical, for glass FO cable 6GK5 992-1AL00-8FA0...
  • Page 25: Installation And Disassembly

    Installation and disassembly Safety notices for installation Safety notices When installing the device, keep to the safety notices listed below. WARNING If a device is operated in an ambient temperature of more than 55 °C, the temperature of the device enclosure may be higher than 70 °C. The device must therefore be installed so that it is only accessible to service personnel or users that are aware of the reason for restricted access and of the required safety measures at an ambient temperature higher than 55 to 70 °C.
  • Page 26 Installation and disassembly 6.1 Safety notices for installation WARNING The device may only be operated in an environment of contamination class 1 or 2 (see EN/IEC 60664-1, GB/T 16935.1). WARNING When used in hazardous environments corresponding to Class I, Division 2 or Class I, Zone 2, the device must be installed in a cabinet or a suitable enclosure.
  • Page 27: Mounting Types

    Installation and disassembly 6.2 Mounting types WARNING Open equipment The devices are "open equipment" according to the standard IEC 61010-2-201 or UL 61010-2-201 / CSA C22.2 No. 61010-2-201. To fulfill requirements for safe operation with regard to mechanical stability, flame retardation, stability, and protection against contact, the following alternative types of installation are specified: •...
  • Page 28: Din Rail Mounting

    Installation and disassembly 6.3 DIN rail mounting Installation clearance Observe the following minimum clearances so that the convection ventilation of the device is not blocked: • Below at least 10 cm • Above at least 10 cm Installation position The following installation position is recommended: Horizontal Horizontal installation of the rack (DIN rail) A reduced maximum temperature may apply in the event of a different installation position;...
  • Page 29 Installation and disassembly 6.3 DIN rail mounting To mount a SCALANCE XCM-100 to a DIN rail, follow the steps below: 1. Place the third enclosure guide of the device on the top edge of the DIN rail. 2. Press the device down against the DIN rail until the spring-loaded securing bar engages. 3.
  • Page 30: Installing On An S7-300 Mounting Rail

    Installation and disassembly 6.4 Installing on an S7-300 mounting rail Installing on an S7-300 mounting rail Installation Figure 6-3 Installing a SCALANCE XCM-100 on an S7-300 mounting rail To mount a SCALANCE XCM-100 to an S7-300 mounting rail, follow the steps below: 1.
  • Page 31 Installation and disassembly 6.4 Installing on an S7-300 mounting rail Removal Figure 6-4 Removing a SCALANCE XCM-100 on an S7-300 mounting rail To remove a SCALANCE XCM-100 from an S7-300 mounting rail, follow the steps below: 1. Lever the spring-loaded securing bar down using a screwdriver as far as it will go. 2.
  • Page 32: Installing On An S7-1500 Mounting Rail

    Installation and disassembly 6.5 Installing on an S7-1500 mounting rail Installing on an S7-1500 mounting rail Installation Figure 6-5 Installing a SCALANCE XCM-100 on an S7-1500 mounting rail To mount a SCALANCE XCM-100 to an S7-1500 mounting rail, follow the steps below: 1.
  • Page 33 Installation and disassembly 6.5 Installing on an S7-1500 mounting rail Removal Figure 6-6 Removing a SCALANCE XCM-100 on an S7-1500 mounting rail To remove a SCALANCE XCM-100 from an S7-1500 mounting rail, follow the steps below: 1. Lever the spring-loaded securing bar down using a screwdriver as far as it will go. 2.
  • Page 34: Wall Mounting

    Installation and disassembly 6.6 Wall mounting Wall mounting Installation ‡ 4,5 ‡ 4,5 Figure 6-7 Drilling template for wall mounting the XCM102 To mount the device on a wall, follow the steps below: 1. Prepare the drill holes. Use suitable dowels for walls made of masonry or concrete. 2.
  • Page 35: Removal

    Installation and disassembly 6.7 Removal Removal WARNING Improper disassembly Improper disassembly may result in a risk of explosion in hazardous areas. For proper disassembly, observe the following: • Before starting work, ensure that the electricity is switched off. • Secure remaining connections so that no damage can occur as a result of disassembly if the system is accidentally started up.
  • Page 36 Installation and disassembly 6.7 Removal SCALANCE XCM-100 Media Converter Operating Instructions, 07/2022, C79000-G8976-C659-01...
  • Page 37: Connecting

    Connecting Safety instructions for operation with a power supply according to NEC Class 2 Operate the device with a power supply according to NEC Class 2. When connecting up the device, keep to the safety notices listed below. For devices that must be operated with a NEC Class 2 power supply, you can also connect a fuse in front of the power supply that meets the following requirements.
  • Page 38: Safety Instructions For Operation With A Power Supply According To Selv

    Connecting 7.2 Safety instructions for operation with a power supply according to SELV NOTICE Suitable fuse for the power supply cables (corresponds to "Limited Energy") The current on the terminal may not exceed 3 A. Use a fuse for the power supply that is suitable for protection of AC/DC power supply circuits * and protects against currents >...
  • Page 39: Safety Instructions On Use In Hazardous Areas

    Connecting 7.3 Safety instructions on use in hazardous areas WARNING Power supply The device is designed for operation with a directly connectable safety extra-low voltage (Safety Extra Low Voltage, SELV) according to UL/IEC 61010‑1 and UL/IEC 61010‑2‑201. Safety instructions on use in hazardous areas General safety notices relating to protection against explosion WARNING EXPLOSION HAZARD...
  • Page 40 Connecting 7.3 Safety instructions on use in hazardous areas WARNING Unprotected cable ends There is a risk of explosion due to unprotected cable ends in hazardous areas. • Protect unused cable ends according to IEC/EN 60079-14. WARNING Improper installation of shielded cables There is a risk of explosion due to equalizing currents between the hazardous area and the non- hazardous area.
  • Page 41: Additional Notes

    Connecting 7.4 Additional notes Safety instructions for use in hazardous locations according to UL/FM HazLoc If you use the device under UL or FM HazLoc conditions, you must also adhere to the following safety instructions in addition to the general safety instructions for protection against explosion: WARNING EXPLOSION HAZARD You may only connect or disconnect cables carrying electricity when the power supply is...
  • Page 42: Wiring Rules

    Connecting 7.5 Wiring rules Note Protective ground A PELV circuit contains a connection to protective ground. Without a connection to protective ground, or in case there is a fault in the connection to the protective ground, the voltage for the circuit is not stabilized.
  • Page 43: Power Supply 24 V Ac / 24 V Dc And Grounding

    Connecting 7.6 Power supply 24 V AC / 24 V DC and grounding Power supply 24 V AC / 24 V DC and grounding Notes on the power supply WARNING Impermissible power supply When the device is connected to a redundant power supply (two separate power supplies), both must meet these requirements.
  • Page 44 The connection of the functional ground must be established directly on the mounting plate or the DIN rail terminal. Position and assignment SCALANCE SIEMENS XCM102 SELECT/ Figure 7-1 Position of the power supply and grounding with SCALANCE XCM-100 and assignment of the...
  • Page 45: Signaling Contact

    Connecting 7.7 Signaling contact Contact Assignment 24 V DC/AC Ground Grounding Signaling contact The signaling contact is connected to a 2-pin plug-in terminal block. The signaling contact (optical relay contact) is a floating switch with which error/fault states can be signaled by breaking the contact.
  • Page 46: Tp Port (Twisted Pair Port)

    Connecting 7.8 TP port (twisted pair port) Position and assignment SCALANCE SIEMENS XCM102 SELECT/ Figure 7-2 Position of the signaling contact with SCALANCE XCM-100 and assignment of the terminal block TP port (twisted pair port) The SCALANCE XCM-100 Media Converter has an RJ45 socket with MDI-X assignment (Medium Dependent Interface autocrossover) as a twisted pair port.
  • Page 47: Sfp Port

    WARNING Use only approved SFP transceivers If you use SFP transceivers that have not been approved by Siemens AG, there is no guarantee that the device will function according to its specifications. If you use unapproved SFP transceivers, this can lead to the following problems: •...
  • Page 48 Connecting 7.9 SFP port NOTICE Failure of the data traffic due to contamination of optical plug-in connections Optical sockets and plugs are sensitive to contamination of the end face. Contamination can lead to the failure of the optical transmission network. Take the following precautions to avoid functional impairments: •...
  • Page 49: Maintenance And Cleaning

    Maintenance and cleaning WARNING Unauthorized repair of devices in explosion-proof design Risk of explosion in hazardous areas • Repair work may only be performed by personnel authorized by Siemens. WARNING Impermissible accessories and spare parts Risk of explosion in hazardous areas •...
  • Page 50 Maintenance and cleaning SCALANCE XCM-100 Media Converter Operating Instructions, 07/2022, C79000-G8976-C659-01...
  • Page 51: Technical Specifications

    Technical specifications Technical specifications of SCALANCE XCM102 Technical specifications Connection to Industrial Ethernet Electrical connectors Quantity Connector RJ45 jack Properties Half/full duplex, MDI‑X assignment Transmission speed 100 / 1000 Mbps Slots for pluggable transceivers Quantity Connector SFP transceiver (LC port) Transmission speed 100/1000 Mbps Electrical data...
  • Page 52 Technical specifications 9.1 Technical specifications of SCALANCE XCM102 Technical specifications Permissible ambient conditions Ambient temperature When operating with plug-in trans‐ During operation in horizontal installation po‐ ceivers of the types: sition of the rack: • SFP991-1 -40 °C to +70 °C During operation in a different installation po‐...
  • Page 53: Mechanical Stability (In Operation)

    Technical specifications 9.4 Cable lengths Mechanical stability (in operation) The device meets the following requirements relating to mechanical stability during operation: • IEC 60068-2-27 shock – 150 m/s , 11 ms duration – 6 shocks per axis • IEC 60068-2-6 vibration –...
  • Page 54 Technical specifications 9.4 Cable lengths SCALANCE XCM-100 Media Converter Operating Instructions, 07/2022, C79000-G8976-C659-01...
  • Page 55: Dimension Drawings

    Dimension drawings Note Dimensions are specified in millimeters. Front view SCALANCE SIEMENS XCM102 SELECT/ SCALANCE XCM-100 Media Converter Operating Instructions, 07/2022, C79000-G8976-C659-01...
  • Page 56 Dimension drawings Side view ‡ 4,8 13,9 ‡ 4,8 SCALANCE XCM-100 Media Converter Operating Instructions, 07/2022, C79000-G8976-C659-01...
  • Page 57: Approvals

    Current approvals on the Internet You will find the current approvals for the product on the Internet pages of Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/15270/cert). Notes for the manufacturers of machines This product is not a machine in the sense of the EC Machinery Directive or the Supply of Machinery (Safety) Regulations (UK).
  • Page 58 DE-76181 Karlsruhe Germany Importer UK: Siemens plc, Manchester M20 2UR You can find the current UK Declaration of Conformity for these products on the Internet pages under Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/ 15270/cert). SCALANCE XCM-100 Media Converter Operating Instructions, 07/2022, C79000-G8976-C659-01...
  • Page 59 You will find this document • on the data medium that ships with some devices. • on the Internet pages under Siemens Industry Online Support. Enter the document identification number "C234" as the search term. The markings of the electrical devices are:...
  • Page 60 Approvals EMC (electromagnetic compatibility) The SIMATIC NET products described in these operating instructions meet the electromagnetic compatibility requirements according to the EU Directive 2014/30/EU as well as the UK- Regulation SI 2016/1091 and their associated amendments. Applied standards: • EN 61000‑6‑2 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments •...
  • Page 61 Approvals Underwriters Laboratories Inc. complying with • UL 62368-1 (information/communication technology) • CSA C22.2 No. 62368-1 (information/communication technology) Report no. E115352 cULus Approval Hazardous Location cULus Listed I. T. E. FOR HAZ. LOC. Underwriters Laboratories Inc. complying with • UL 62368-1 (information/communication technology) •...
  • Page 62 • "Industrial Ethernet / PROFINET Industrial Ethernet" System Manual (https:// support.industry.siemens.com/cs/ww/en/view//27069465) • "Industrial Ethernet / PROFINET - Passive Network Components" System Manual (https:// support.industry.siemens.com/cs/ww/en/view/84922825) • "EMC Installation Guidelines" configuration manual (https:// support.industry.siemens.com/cs/ww/en/view/60612658)
  • Page 63 Approvals Note The test was performed with a device and a connected communications partner that also meets the requirements of the standards listed above. When operating the device with a communications partner that does not comply with these standards, adherence to the corresponding values cannot be guaranteed. SCALANCE XCM-100 Media Converter Operating Instructions, 07/2022, C79000-G8976-C659-01...
  • Page 64 Approvals SCALANCE XCM-100 Media Converter Operating Instructions, 07/2022, C79000-G8976-C659-01...
  • Page 65: Index

    Index Accessories, 22 Grounding, 19, 44 Ambient conditions, 52 Terminal block, 44 Approvals, 57 Article numbers, 17 Auto polarity exchange, 47 Autonegotiation, 46 Industrial Ethernet, 51 Installation, 27 DIN rail, 28 Installation location, 28 Button, 19, 21 Minimum clearances, 28 S7-1500 mounting rail, 32 S7-300 mounting rail, 30 Wall, 34...
  • Page 66 Index RF radiation, 53 RJ45 port, 19, 46 Safety notices for installation, 25 general, 9 Use in hazardous areas, 9, 25 Scope of delivery, 18 SET/SELECT, 21 SFP port, 19, 47 SFP transceiver, 23, 24 SFP transceivers, 47 Signaling contact, 19, 20, 45 Spring-loaded terminal, 43 Startup phase, 20 System manual, 62...

Table of Contents