Device description

5.8 Accessories

Phase
Description
3
This new status is adopted and stored as the new fault mask in phase 3.
LEDs flashing
LEDs lit
Note
If an empty fault mask is set or needs to be set, the 2 port LEDs flash alternately. If the fault mask
is empty, no port is monitored.
Error/fault
If the link is lost at a monitored port or a monitored power supply is lost, this is signaled as
follows:
• The red alarm LED lights up
• The signaling contact is open
5.8
Accessories
Component
IE FC Stripping Tool
IE FC blade cassettes
IE FC TP standard cable GP
IE FC TP trailing cable
IE FC TP marine cable
IE FC TP trailing cable GP
IE FC TP flexible cable GP
IE FC RJ45 Plug 180
IE FC RJ45 Plug 180
IE FC RJ45 Plug 180
IE FC RJ45 plug 180 4x 2,
10/100/1000 Mbps
22
If you release the SET button while the LEDs are still flashing, saving is
aborted.
If you release the SET button as soon as the LEDs light up, the current
settings will be stored.
The stored status is displayed.
The monitored ports are indicated by statically lit LEDs.
The monitored power supply is indicated by statically lit LEDs.
Packaging unit
1
1
1
1
1
1
1
1
10
50
1
Operating Instructions, 07/2022, C79000-G8976-C659-01
Article number
6GK1 901-1GA00
6GK1 901-1GB00
6XV1 840 2AH10
6XV1 840-3AH10
6XV1 840-4AH10
6XV1 870-2D
6XV1 870-2B
6GK1 901-1BB10-2AA0
6GK1 901-1BB10-2AB0
6GK1 901-1BB10-2AE0
6GK1901-1BB11-2AA0
SCALANCE XCM-100 Media Converter

Advertisement

Table of Contents
loading

Table of Contents