SIMATIC NET
Industrial Ethernet
SCALANCE X101-1
SCALANCE X101-1FL
SCALANCE X101-1LD
SCALANCE X101-1POF
Commissioning Manual
07/2008
A2B00051521A
Preface
Introduction
Network Topologies
Product Characteristics
Installation and Maintenance
Notes on the CE Mark
References
Dimension Drawings
1
2
3
4
5
6
7
8

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SCALANCE X101-1

  • Page 1 Preface Introduction Network Topologies Product Characteristics SIMATIC NET Industrial Ethernet Installation and Maintenance SCALANCE X101-1 SCALANCE X101-1FL SCALANCE X101-1LD Notes on the CE Mark SCALANCE X101-1POF References Commissioning Manual Dimension Drawings 07/2008 A2B00051521A...
  • Page 2: Safety Guidelines

    Siemens. This product can only function correctly and safely if it is transported, stored, set up and installed correctly, and operated and maintained as recommended.
  • Page 3: Table Of Contents

    SCALANCE X101-1 Product Characteristics................4-3 4.2.4 SCALANCE X101-1 TP Port...................... 4-4 4.2.5 SCALANCE X101-1 FO Port ..................... 4-5 4.2.6 SCALANCE X101-1 Power Supply and Signaling Contact ............4-6 4.2.7 SCALANCE X101-1 Button......................4-7 4.2.8 Cascade Connection of two Media Converters ................. 4-8 4.2.9 SCALANCE X101-1 Displays ....................
  • Page 4 Figure 3-3 Electrical Ring, Example with SCALANCE X204IRT as Redundancy Manager, X208 and conversion to a Optical Line with SCALANCE X101-1 or X101-1LD Media converter ..... 3-2 Figure 3-4 Optical Ring, Example with SCALANCE X-400 as Redundancy Manager, X204-2 and a extension for Optical Lines with SCALANCE X101-1LD Media converter ........
  • Page 5: Table Of Contents

    Table of Contents Figure 3-5 Stand-By Coupling of two Redundant Rings via Master / Slave Concept of SCALANCE X-400. Coupling is realized with SCALANCE X101-1 or X101-1LD Media converter ......3-4 Figure 4-1 SCALANCE X101-1 ........................4-3 Figure 4-2 RJ-45 connector pinout......................4-4 Figure 4-3 Power supply SCALANCE X101-1 ....................
  • Page 7: Preface

    This commissioning manual supports you when commissioning networks with the media converters of the SCALANCE X-100 series. Validity of this Commissioning Manual This commissioning manual is valid for the following devices: SIMATIC NET SCALANCE X101-1 6GK5101-1BB00-2AA3 SIMATIC NET SCALANCE X101-1FL 6GK5101-1BY00-2AA3...
  • Page 8: Note On The Ce Mark"

    Preface 1.1 Preface Standards and Approvals The media converters of the SCALANCE X-100 series meet the requirements for the CE mark. For detailed information please refer to the chapter “ Notes on the CE Mark” of this commissioning manual. The media converters of the SCALANCE X-100 series meet the requirements for the UL , C- Tick , FM and ATEX marks .
  • Page 9: Introduction

    Blitzductor VT AD 24V type no. 918 402 is used Manufacturer: DEHN+SÖHNE GmbH + Co. KG Hans Dehn Str.1 Postfach 1640 D-92306 Neumarkt, Germany Only SCALANCE X101-1 or SCALANCE X101-1LD or SCALANCE X101-1POF Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A...
  • Page 10 Introduction 2.1 Introduction Warning When used under hazardous conditions (zone 2), the media converter of the SCALANCE X- 100 series must be installed in an enclosure. In the scope of ATEX100a (EN 60079-15), this enclosure must at least comply with IP54 according to EN 60529.
  • Page 11: Network Topologies

    Please compare in chapter 4 Product Characteristics, subsection Cascade, of the concerning media converter. Bus Topology Figure 3-1 Electrical/optical bus topology with SCALANCE X101-1 Only SCALANCE X101-1 or SCALANCE X101-1LD or SCALANCE X101-1POF Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A...
  • Page 12: Figure 3-2 Optical Ring, Example With Scalance X-400 As Redundancy Manager, X204-2 And A Extension For Optical Lines With Scalance X101-1Ld Media Converter

    See in chapter 4 Product Characteristics, subsection Cascade, of the concerning media converter. Figure 3-3 Electrical Ring, Example with SCALANCE X204IRT as Redundancy Manager, X208 and conversion to a Optical Line with SCALANCE X101-1 or X101-1LD Media converter Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A...
  • Page 13: Figure 3-4 Optical Ring, Example With Scalance X-400 As Redundancy Manager, X204-2 And A Extension For Optical Lines With Scalance X101-1Ld Media Converter

    Network Topologies 3.1 Network Topologies Figure 3-4 Optical Ring, Example with SCALANCE X-400 as Redundancy Manager, X204-2 and a extension for Optical Lines with SCALANCE X101-1LD Media converter Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A...
  • Page 14: Coupling Of Network Segments

    3.2 Coupling of Network Segments 3.2 Coupling of Network Segments The coupling of two ring network topologies using two SCALANCE X101-1 media converters shown here as an example is only possible indirectly via nodes with redundancy capability (e.g. SCALANCE X-400). This applies to all media converters of the SCALANCE X-100 series.
  • Page 15: Product Characteristics

    Product Characteristics 4.1 Overview Table 4-1 Overview of the product characteristics Characteristics Device type X101-1 X101-1FL X101-1LD X101-1POF SIMATIC environment Diagnostics LED 24V DC Compact housing 40mm (securing collar, etc.) 2x 24 V DC Signaling contact + on-site operation Diagnostics: Web, SNMP, PROFINET C-PLUG Ring redundancy with RM...
  • Page 16: Scalance X101-1

    Do not use any parts that show evidence of damage! Warning If the SCALANCE X101-1 device is operated in ambient temperatures between 55°C- 60°C, the temperature of the device housing may be higher than 70°C. The subject unit must be located in a Restricted Access Location where access can only...
  • Page 17: Scalance X101-1 Product Characteristics

    4.2.3 SCALANCE X101-1 Product Characteristics Possible Attachments The SCALANCE X101-1 media converter features an RJ-45 jack and a BFOC port for the connection of DTEs or other network segments. Note The BFOC socket (Bayonet Fiber Optic Connector) corresponds to the ST socket...
  • Page 18: Scalance X101-1 Tp Port

    Pin 3 Pin 2 Pin 1 On SCALANCE X101-1, the twisted pair port is implemented as RJ-45 jack with MDI-X assignment (Medium Dependent Interface–Autocrossover) of a network component. Notice TP cords or TP-XP cords with a maximum length of 10 m can be connected to the RJ-45 TP port.
  • Page 19: Scalance X101-1 Fo Port

    All media converters of the SCALANCE X-100 series support the MDI / MDIX autocrossover function. 4.2.5 SCALANCE X101-1 FO Port Transmission Speed The transmission rate of the optical Fast Ethernet port is 100 Mbps. Transmission Mode The transmission mode for 100Base-FX is specified in the IEEE 802.3 standard.
  • Page 20: Scalance X101-1 Power Supply And Signaling Contact

    (SELV) complying with IEC950/EN60950/ VDE0805 can be connected to the power supply terminals. The power supply unit to supply SCALANCE X101-1 must comply with NEC Class 2 (voltage range 18-32 V, current requirement 200 mA).
  • Page 21: Scalance X101-1 Button

    The signaling contact is connected to a 2-pin plug-in terminal block. The signaling contact (optical relay contact) is a floating switch with which error/fault states are signaled by contact separation. Figure 4-5 Signaling contact SCALANCE X101-1 Figure 4-6 Connector pinout...
  • Page 22: Cascade Connection Of Two Media Converters

    Product Characteristics 4.2 SCALANCE X101-1 If an empty fault mask (no port is monitored) is set or is to be set, the 2 port LEDs flash alternatingly. Simultaneously with the fault mask, the monitoring of the connected power supply is set. The existence of the two power supply units is only monitored if both power supplies are connected during saving the fault mask.
  • Page 23: Scalance X101-1 Displays

    Fault indicator (red LED) ) Status Meaning Lit red SCALANCE X101-1 detects an error. Simultaneously the signaling contact opens. The following errors are detected: 1. Link down event at a monitored port. 2. Failure of the supply voltage or supply voltage less than 14 V of one of the two redundant power supplies.
  • Page 24 Product Characteristics 4.2 SCALANCE X101-1 Transparent link display (green LED) “TL” (transparent link) LED: Status Meaning Lit green Transparent link parameterized. Not lit Stand-alone mode. DTEs are connected to both ports of the media converter (no cascading) See chapter 4.2.8 "Important notes"!
  • Page 25: Scalance X101-1 Technical Specifications

    Product Characteristics 4.2 SCALANCE X101-1 4.2.10 SCALANCE X101-1 Technical Specifications Technical Specifications of SCALANCE X101-1 Ports Attachment of DTEs or network components over 1xRJ-45 socket with MDI-X pinning 100 Mbps twisted pair full duplex Connection of further network components over...
  • Page 26 Product Characteristics 4.2 SCALANCE X101-1 Permitted Environmental Conditions / EMC Operating temperature -10°C to +60°C Storage/transport temperature -40°C to +80°C Relative humidity in operation ‹ 95% (no condensation) Operating altitude 2000 m at max 56 °C ambient temperature 3000 m at max. 50 °C ambient temperature...
  • Page 27 Product Characteristics 4.2 SCALANCE X101-1 Order Numbers SCALANCE X101-1 6GK5101-1BB00-2AA3 "Industrial Ethernet TP and Fiber Optic Networks" 6GK1970-1BA10-0AA0 manual IE FC stripping tool 6GK1901-1GA00 IE FC blade cassettes 6GK1901-1GB00 IE FC TP standard cable GP 6XV1840 2AH10 IE FC TP trailing cable...
  • Page 28: Scalance X101-1Fl

    Product Characteristics 4.3 SCALANCE X101-1FL 4.3 SCALANCE X101-1FL 4.3.1 SCALANCE X101-1FL Components Supplied What ships with the media converter? • SCALANCE X101-1FL device • 2-pin plug-in terminal block • 4-pin plug-in terminal block • Product information • CD – Commissioning manual (this document) –...
  • Page 29: Scalance X101-1Fl Product Characteristics

    Product Characteristics 4.3 SCALANCE X101-1FL 4.3.3 SCALANCE X101-1FL Product Characteristics Possible Attachments The SCALANCE X101-1FL media converter features an RJ-45 jack and a BFOC port for the connection of DTEs or other network segments. Note The BFOC socket (Bayonet Fiber Optic Connector) corresponds to the ST socket Figure 4-7 SCALANCE X101-1FL Industrial Ethernet Media Converters SCALANCE X-100 Series...
  • Page 30: Scalance X101-1Fl Tp Port

    Product Characteristics 4.3 SCALANCE X101-1FL 4.3.4 SCALANCE X101-1FL TP Port Connector Pinout RJ-45 jack Figure 4-8 RJ-45 connector pinout Pin number Pinout Pin 8 Pin 7 Pin 6 Pin 5 Pin 4 Pin 3 Pin 2 Pin 1 On SCALANCE X101-1FL, the twisted pair port is implemented as RJ-45 jack with MDI-X assignment (Medium Dependent Interface–Autocrossover) of a network component.
  • Page 31: Scalance X101-1Fl Fo Port

    Product Characteristics 4.3 SCALANCE X101-1FL MDI /MDIX Autocrossover Function The advantage of the MDI /MDIX autocrossover function is that straight-through cables can be used throughout and crossover Ethernet cables are unnecessary. This prevents malfunctions resulting from mismatching send and receive wires. This makes installation much easier for the user.
  • Page 32: Scalance X101-1Fl Power Supply And Signaling Contact

    Product Characteristics 4.3 SCALANCE X101-1FL Connectors The cables are connected to BFOC sockets. 4.3.6 SCALANCE X101-1FL Power Supply and Signaling Contact Power Supply The power supply is connected using a 4-pin plug-in terminal block. The power supply can be connected redundantly. Both inputs are isolated. There is no distribution of load. When using a redundant power supply, the power supply unit with the higher output voltage supplies SCALANCE X101-1FL alone.
  • Page 33: Figure 4-12 Connector Pinout

    Product Characteristics 4.3 SCALANCE X101-1FL Signaling Contact The signaling contact is connected to a 2-pin plug-in terminal block. The signaling contact (optical relay contact) is a floating switch with which error/fault states are signaled by contact separation. Figure 4-11 Signaling contact SCALANCE X101-1FL Figure 4-12 Connector pinout Pin number...
  • Page 34: Scalance X101-1Fl Button

    Product Characteristics 4.3 SCALANCE X101-1FL 4.3.7 SCALANCE X101-1FL Button What is the function of the button? Using the button , you can display and modify the set fault mask. After continuously pressing the button, the currently valid fault mask is displayed for approximately 3 seconds.
  • Page 35: Scalance X101-1Fl Displays

    Product Characteristics 4.3 SCALANCE X101-1FL It is mandatory that a cascade connection is set at both (!) media converters using • the button (“ TL” LED must be illuminated). If this is not done, malfunctions can occur. The setting remains after turning on/off. •...
  • Page 36 Product Characteristics 4.3 SCALANCE X101-1FL Note The link state of port P1 and port P2 (LED lit green) in stand-alone-mode is only indicated if both ports have link at the same time. Transparent link display (green LED) The TL LED has no function. “TL”...
  • Page 37: Scalance X101-1Fl Technical Specifications

    Product Characteristics 4.3 SCALANCE X101-1FL 4.3.10 SCALANCE X101-1FL Technical Specifications SCALANCE X101-1FL Technical Specifications Ports Attachment of DTEs or network components over 1xRJ-45 socket with MDI-X pinning 10 Mbps twisted pair half duplex Connection of further network components over 2 BFOC sockets (10 Mbps, half duplex to 10 BaseFL) Connector for power supply 1x4-pin plug-in terminal block...
  • Page 38 Product Characteristics 4.3 SCALANCE X101-1FL Permitted Environmental Conditions / EMC Operating temperature -10°C to +60°C Storage/transport temperature -40°C to +80°C Relative humidity in operation ‹ 95% (no condensation) Operating altitude 2000 m at max 56 °C ambient temperature 3000 m at max. 50 °C ambient temperature RF interference level EN 61000-6-3 Noise immunity...
  • Page 39 Product Characteristics 4.3 SCALANCE X101-1FL Order Numbers SCALANCE X101-1FL 6GK5101-1BY00-2AA3 "Industrial Ethernet TP and Fiber Optic Networks" 6GK1970-1BA10-0AA0 manual IE FC stripping tool 6GK1901-1GA00 IE FC blade cassettes 6GK1901-1GB00 IE FC TP standard cable GP 6XV1840 2AH10 IE FC TP trailing cable 6XV1840-3AH10 IE FC TP marine cable 6XV1840-4AH10...
  • Page 40: Scalance X101-1Ld

    Product Characteristics 4.4 SCALANCE X101-1LD 4.4 SCALANCE X101-1LD 4.4.1 SCALANCE X101-1LD Components Supplied What ships with the media converter? • SCALANCE X101-1LD device • 2-pin plug-in terminal block • 4-pin plug-in terminal block • Product information • CD – Commissioning manual (this document) –...
  • Page 41: Scalance X101-1Ld Product Characteristics

    Product Characteristics 4.4 SCALANCE X101-1LD 4.4.3 SCALANCE X101-1LD Product Characteristics Possible Attachments The media converter of SCALANCE X101-1LD features an RJ-45 jack and a BFOC port for the connection of DTEs or other network segments. Note The BFOC socket (Bayonet Fiber Optic Connector) corresponds to the ST socket Figure 4-13 SCALANCE X101-1LD Industrial Ethernet Media Converters SCALANCE X-100 Series...
  • Page 42: Scalance X101-1Ld Tp Port

    Product Characteristics 4.4 SCALANCE X101-1LD 4.4.4 SCALANCE X101-1LD TP Port Connector pinout RJ-45 jack Figure 4-14 RJ-45 connector pinout Pin number Pinout Pin 8 Pin 7 Pin 6 Pin 5 Pin 4 Pin 3 Pin 2 Pin 1 On SCALANCE X101-1LD, the twisted pair port is implemented as RJ-45 jack with MDI-X assignment (Medium Dependent Interface–Autocrossover) of a network component.
  • Page 43: Scalance X101-1Ld Fo Port

    Product Characteristics 4.4 SCALANCE X101-1LD Note Devices not supporting autonegotiation must be set to 100 Mbps/ half duplex. MDI /MDIX Autocrossover Function The advantage of the MDI /MDIX autocrossover function is that straight-through cables can be used throughout and crossover Ethernet cables are unnecessary. This prevents malfunctions resulting from mismatching send and receive wires.
  • Page 44: Scalance X101-1Ld Power Supply And Signaling Contact

    Product Characteristics 4.4 SCALANCE X101-1LD Range The maximum transmission range (segment length) is 26 km if the signal attenuation of the FOC is ≤ 0.5 dB/km. Connectors The cables are connected to BFOC sockets. 4.4.6 SCALANCE X101-1LD Power Supply and Signaling Contact Power Supply The power supply is connected using a 4-pin plug-in terminal block.
  • Page 45: Figure 4-18 Connector Pinout

    Product Characteristics 4.4 SCALANCE X101-1LD Warning The SCALANCE X101-1LD device is designed for operation with safety extra-low voltage. This means that only safety extra-low voltages (SELV) complying with IEC950/EN60950/ VDE0805 can be connected to the power supply terminals. The power supply unit to supply SCALANCE X101-1LD must comply with NEC Class 2 (voltage range 18-32 V, current requirement 200 mA).
  • Page 46: Scalance X101-1Ld Button

    Product Characteristics 4.4 SCALANCE X101-1LD 4.4.7 SCALANCE X101-1LD Button What is the function of the button? Using the button , you can display and modify the set fault mask and set the transparent link mode (see chapter 4.4.8). After continuously pressing the button, the currently valid fault mask is displayed for approximately 3 seconds.
  • Page 47: Scalance X101-1Ld Displays

    Product Characteristics 4.4 SCALANCE X101-1LD It is mandatory that a cascade connection is set at both (!) media converters using • the button (“ TL” LED must be illuminated). If this is not done, malfunctions can occur. The setting remains after turning on/off. •...
  • Page 48 Product Characteristics 4.4 SCALANCE X101-1LD Note The link state of port P1 and port P2 (LED lit green) in stand-alone-mode is only indicated if both ports have link at the same time. In transparent link mode the link state is also recognized and indicated by the optical port(P2) without a link at the port P1 (see chapter 4.4.8).
  • Page 49: Scalance X101-1Ld Technical Specifications

    Product Characteristics 4.4 SCALANCE X101-1LD 4.4.10 SCALANCE X101-1LD Technical Specifications SCALANCE X101-1LD Technical Specifications Ports Attachment of DTEs or network components over 1xRJ-45 socket with MDI-X pinning 100 Mbps twisted pair full duplex Connection of further network components over 2 BFOC sockets (100 Mbps, full duplex to 100 BaseFX) Connector for power supply 1x4-pin plug-in terminal block...
  • Page 50 Product Characteristics 4.4 SCALANCE X101-1LD Permitted Environmental Conditions / EMC Operating temperature -10°C to +60°C Storage/transport temperature -40°C to +80°C Relative humidity in operation ‹ 95% (no condensation) Operating altitude 2000 m at max 56 °C ambient temperature 3000 m at max. 50 °C ambient temperature RF interference level EN 61000-6-4 Noise immunity...
  • Page 51 Product Characteristics 4.4 SCALANCE X101-1LD Order Numbers SCALANCE X101-1LD 6GK5101-1BC00-2AA3 "Industrial Ethernet TP and Fiber Optic Networks" 6GK1970-1BA10-0AA0 manual IE FC stripping tool 6GK1901-1GA00 IE FC blade cassettes 6GK1901-1GB00 IE FC TP standard cable GP 6XV1840 2AH10 IE FC TP trailing cable 6XV1840-3AH10 IE FC TP marine cable 6XV1840-4AH10...
  • Page 52: Scalance X101-1Pof

    Product Characteristics 4.5 SCALANCE X101-1POF 4.5 SCALANCE X101-1POF 4.5.1 SCALANCE X101-1POF Components Supplied What ships with the media converter? • SCALANCE X101-1POF device • 2-pin plug-in terminal block • 4-pin plug-in terminal block • Product information • CD – Commissioning manual (this document) –...
  • Page 53: Scalance X101-1Pof Product Characteristics

    Product Characteristics 4.5 SCALANCE X101-1POF 4.5.3 SCALANCE X101-1POF Product Characteristics Possible Attachments The media converter of SCALANCE X101-1POF features an RJ-45 jack and an SC-RJ interface for the connection of DTEs or other network segments. Figure 4-19 SCALANCE X101-1POF Industrial Ethernet Media Converters SCALANCE X-100 Series 4-39 Commissioning Manual, 07/2008, A2B00051521A...
  • Page 54: Scalance X101-1Pof Tp Port

    Product Characteristics 4.5 SCALANCE X101-1POF 4.5.4 SCALANCE X101-1POF TP Port Connector pinout RJ-45 jack Figure 4-20 RJ-45 connector pinout Pin number Pinout Pin 8 Pin 7 Pin 6 Pin 5 Pin 4 Pin 3 Pin 2 Pin 1 On SCALANCE X101-1POF, the twisted pair port is implemented as RJ-45 jack with MDI-X assignment (Medium Dependent Interface–Autocrossover) of a network component.
  • Page 55: Scalance X101-1Pof Fo Port

    Product Characteristics 4.5 SCALANCE X101-1POF Note Devices not supporting autonegotiation must be set to 100 Mbps / half duplex. MDI /MDIX Autocrossover Function The advantage of the MDI /MDIX autocrossover function is that straight-through cables can be used throughout and crossover Ethernet cables are unnecessary. This prevents malfunctions resulting from mismatching send and receive wires.
  • Page 56: Scalance X101-1Pof Power Supply And Signaling Contact

    Product Characteristics 4.5 SCALANCE X101-1POF 4.5.6 SCALANCE X101-1POF Power Supply and Signaling Contact Power Supply The power supply is connected using a 4-pin plug-in terminal block. The power supply can be connected redundantly. Both inputs are isolated. There is no distribution of load. When using a redundant power supply, the power supply unit with the higher output voltage supplies SCALANCE X101-1POF alone.
  • Page 57: Figure 4-24 Connector Pinout

    Product Characteristics 4.5 SCALANCE X101-1POF Signaling Contact The signaling contact is connected to a 2-pin plug-in terminal block. The signaling contact (optical relay contact) is a floating switch with which error/fault states are signaled by contact separation. Figure 4-23 Signaling contact SCALANCE X101-1POF Figure 4-24 Connector pinout Pin number Pinout...
  • Page 58: Scalance X101-1Pof Button

    Product Characteristics 4.5 SCALANCE X101-1POF 4.5.7 SCALANCE X101-1POF Button What is the function of the button? Using the button , you can display and modify the set fault mask and set the transparent link mode (see chapter 4.5.8). After continuously pressing the button, the currently valid fault mask is displayed for approximately 3 seconds.
  • Page 59: Scalance X101-1Pof Displays

    Product Characteristics 4.5 SCALANCE X101-1POF It is mandatory that a cascade connection is set at both (!) media converters using • the button (“ TL” LED must be illuminated). If this is not done, malfunctions can occur. The setting remains after turning on/off. •...
  • Page 60 Product Characteristics 4.5 SCALANCE X101-1POF Note The link state of port P1 and port P2 (LED lit green) in stand-alone-mode is only indicated if both ports have link at the same time. In transparent link mode the link state is also recognized and indicated by the optical port(P2) without a link at the port P1 (see chapter 4.5.8).
  • Page 61: Scalance X101-1Pof Technical Specifications

    Product Characteristics 4.5 SCALANCE X101-1POF 4.5.10 SCALANCE X101-1POF Technical Specifications SCALANCE X101-1POF Technical Specifications Ports Attachment of DTEs or network components over 1xRJ-45 socket with MDI-X pinning 100 Mbps twisted pair full duplex Connection of further network components over 2 SC-RJ sockets (100 Mbps, full duplex to 100 BaseFX) Connector for power supply 1x4-pin plug-in terminal block...
  • Page 62 Product Characteristics 4.5 SCALANCE X101-1POF Permitted Environmental Conditions / EMC Operating temperature -10°C to +60°C Storage/transport temperature -40°C to +80°C Relative humidity in operation ‹ 95% (no condensation) Operating altitude 2000 m at max 56 °C ambient temperature 3000 m at max. 50 °C ambient temperature RF interference level EN 61000-6-3 Noise immunity...
  • Page 63 Product Characteristics 4.5 SCALANCE X101-1POF Order Numbers SCALANCE X101-1POF 6GK5101-1BH00-2AA3 "Industrial Ethernet TP and Fiber Optic Networks" 6GK1970-1BA10-0AA0 manual IE FC stripping tool 6GK1901-1GA00 IE FC blade cassettes 6GK1901-1GB00 IE FC TP standard cable GP 6XV1840 2AH10 IE FC TP trailing cable 6XV1840-3AH10 IE FC TP marine cable 6XV1840-4AH10...
  • Page 65: Installation And Maintenance

    Installation and Maintenance 5.1 Installation Types of Installation The media converters of the SCALANCE X-100 series can be mounted in different ways: • Installation on a 35 mm DIN rail • Installation on a SIMATIC S7-300 DIN rail • Wall mounting Note When installing and operating the device, keep to the installation instructions and safety- related notices as described here and in the SIMATIC NET Industrial Ethernet Twisted Pair...
  • Page 66: Installation On A Din Rail

    Installation and Maintenance 5.1 Installation 5.1.1 Installation on a DIN Rail Installation Install the media converter on a 35 mm DIN rail according to DIN EN 50022. Place the upper catch of the device over the top of the rail and then push in the lower part of the device against the rail until it clips into place.
  • Page 67 Installation and Maintenance 5.1 Installation Uninstalling To remove the media converter from the DIN rail: First disconnect the TP cable and the FO cables. Remove the terminal block for the power supply and the signaling contact. Use a screwdriver to release the lower rail catch of the device and pull the lower part of the device away from the rail.
  • Page 68: Installation On A Simatic S7 Din Rail

    Installation and Maintenance 5.1 Installation 5.1.2 Installation on a SIMATIC S7 DIN Rail Installation on a SIMATIC S7-300 DIN rail Place the upper guide at the top of the SCALANCE housing in the S7 DIN rail. Screw the media converter of the SCALANCE X-100 series to the underside of the DIN rail.
  • Page 69: Wall Mounting

    Installation and Maintenance 5.2 Grounding 5.1.3 Wall Mounting Wall Mounting Use four wall plugs (6 mm diameter and 30 mm long). To attach the device, use screws with a diameter of 3.5 mm and a length of 40 mm. Note the drilling templates in chapter 8 Dimension Drawings. Note The wall mounting must be capable of supporting at least four times the weight of the device.
  • Page 70: Assembling The Ie Fc Standard Cable

    Installation and Maintenance 5.3 Assembling the IE FC Standard Cable 5.3 Assembling the IE FC Standard Cable Assemble the IE FC RJ-45 plug 180 and the IE FC standard cable as follows For information on the assembly, please refer to the instructions that ship with the IE FC RJ-45 plug 180.
  • Page 71 Installation and Maintenance 5.3 Assembling the IE FC Standard Cable Inserting the IE FC RJ-45 plug 180 Insert the IE FC RJ-45 plug 180 in the twisted pair port of SCALANCE X005 or of the devices of the product lines SCALANCE X-100 or X-200 until it snaps into place. Figure 5-5 Inserting the IE FC RJ-45 plug 180 Due to the closing shape and the latching with the PROFINET-compliant connector IE FC...
  • Page 72: Maintenance

    30 minutes before it can be turned on again. If any different fault develops, please send the device to your SIEMENS service center for repair. Repairs on-site are not possible.
  • Page 73: Notes On The Ce Mark

    Notes on the CE Mark 6.1 Notes on the CE Mark Product Name SIMATIC NET SCALANCE X101-1 6GK5101-1BB00-2AA3 SIMATIC NET SCALANCE X101-1FL 6GK5101-1BY00-2AA3 SIMATIC NET SCALANCE X101-1LD 6GK5101-1BC00-2AA3 SIMATIC NET SCALANCE X101-1POF 6GK5101-1BH00-2AA3 EMC Directive 89/336/EEC "Electromagnetic Compatibility" Area of Application...
  • Page 74 6.1 Notes on the CE Mark Conformity Certificates The EU declaration of conformity is available for the responsible authorities according to the above-mentioned EU directive at the following address: Siemens Aktiengesellschaft Bereich Automatisierungs- und Antriebstechnik Industrielle Kommunikation (A&D PT2) Postfach 4848 D-90327 Nürnberg...
  • Page 75: References

    References 7.1 References Sources of Information and Other Documentation SIMATIC NET Industrial Twisted Pair and Fiber Optic Networks Order numbers: 6GK1970-1BA10-0AA0 German 6GK1970-1BA10-0AA1 English 6GK1970-1BA10-0AA2 French 6GK1970-1BA10-0AA4 Italian PROFINET Installation Guide can be ordered from the PROFIBUS User Organization (PNO) Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A...
  • Page 77: Dimension Drawings

    Dimension Drawings 8.1 Dimension Drawing Figure 8-1 Dimension drawing Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A...
  • Page 78: Figure 8-2 Dimension Drawing / Side View

    Dimension Drawings 8.1 Dimension Drawing Figure 8-2 Dimension drawing / Side view Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A...
  • Page 79: Figure 8-3 Bending Radii

    Dimension Drawings 8.1 Dimension Drawing Figure 8-3 Bending radii Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A...
  • Page 81 Glossary Attachment Unit Interface. 10 Mbps TP port (15-pin sub D) for connecting an AUI drop cable. Can be implemented either as DTE (data terminal equipment) or as DCE (data carrier equipment). Is primarily used for the connection to triax segments. Autocrossover Method with which a TP port is automatically switched between MDI and MDI-X assignment to establish a connection independently of the port assignment of the device to be...
  • Page 82 Glossary Fault Mask Definition of a desired status (good status); deviations from this status during operation are considered as errors/faults. Fiber optic Monomode The monomode fiber (also single-mode fiber) typically has a core diameter of 5 to 9 µm. However, the outer diameter is also 125 µm. The actual transmission of the information takes place in the core of the fiber.
  • Page 83 Glossary Reconfiguration Time Time required to restore a functional configuration in case of a device failure or an interruption of a connection line. Redundancy Manager (RM) Switch in a ring topology which does not forward frames between its ring ports in case of functioning connections between all other switches.
  • Page 85 Index ATEX, 1-2, 2-2 MDI /MDIX autocrossover function Autonegotiation SCALANCE X101-1, 4-5 SCALANCE X101-1, 4-4 SCALANCE X101-1LD, 4-29 SCALANCE X101-1LD, 4-28 MDI /MDIX Autocrossover function SCALANCE X101-1POF, 4-40 SCALANCE X101-1FL, 4-17 SCALANCE X101-1POF, 4-41 Button SCALANCE X101-1, 4-7 Network topology, 3-1...
  • Page 86 Index Ring topology, 3-2, 3-3 Signaling contact SCALANCE X101-1, 4-7 SCALANCE X101-1FL, 4-19 SCALANCE X101-1LD, 4-31 SCALANCE X101-1POF, 4-43 TL display (green LED) SCALANCE X101-1, 4-10 SCALANCE X101-1FL, 4-22 SCALANCE X101-1LD, 4-34 SCALANCE X101-1POF, 4-46 UL mark, 1-2 Industrial Ethernet Media Converters SCALANCE X-100 Series...