Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommend- ed or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Preface ............................v Related Documents ......................... v Accessing Documentation ....................... v Training ........................... v Customer Support ........................vi Contacting Siemens ........................ vi Introduction ........................... 1 Feature Highlights ....................1 Description ......................2 Required Tools and Materials ................. 3 Decommissioning and Disposal ................3 Cabling Recommendations ..................
Page 5
Table of Contents GBIC Optic Ethernet Ports ..................28 4.5.1 Installing a GBIC Optical Port ................28 4.5.2 Removing a GBIC Optical Port ................30 Technical Specifications ...................... 33 Power Supply Specifications ................33 PoE Power Supply Specifications ................33 Failsafe Relay Specifications ................
Siemens Customer Support. Training Siemens offers a wide range of educational services ranging from in-house training of standard courses on networking, Ethernet switches and routers, to on-site cus- tomized courses tailored to the customer's needs, experience and application.
Preface Customer Support Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request to submit a Support Request (SR) or check on the status of an existing SR.
Introduction The RUGGEDCOM RSG2100P is a rugged, Power over Ethernet (PoE) enabled, fully managed, modular Ethernet switch specifically designed to operate reliably in electri- cally harsh and climatically demanding utility substation, railway and industrial envi- ronments. The RUGGEDCOM RSG2100P’s superior rugged hardware design coupled with the embedded Rugged Operating System (ROS) provides improved system reli- ability and advanced cyber security and networking features, making it ideally suited for creating Ethernet networks for mission-critical, real-time, control applications.
Introduction 1.3 Required Tools and Materials Mode Color/State Description No link detected Duplex Green Full duplex mode Orange Half duplex mode No link detected Speed Green (Solid) 100 Mbps Green (Blinking) 1000 Mbps Orange (Solid) 10 Mbps No link detected Display Mode Indicator LEDs The display mode indicator LEDs indicate the current display mode for the port status indicator LEDs (i.e.
Siemens also does not recommend using copper Ethernet ports to interface with de- vices in the field across distances that could produce high levels of ground potential rise (i.e.
Introduction 1.5.3 Supported Fiber Optic Cables Cabling 1000Base- Required Action Category TX Compliant Verify TIA/EIA-568-A compliance. No action required. New installations should be designed with Cate- gory 5e or higher. No action required. > 6 Connector and wiring standards to be determined. Follow these recommendations for copper data cabling in high electrical noise envi- ronments: •...
This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
Visually inspect each item in the package for any physical damage. Verify all items are included. NOTICE If any item is missing or damaged, contact Siemens for assistance. Mounting the Device The RUGGEDCOM RSG2100P is designed for maximum mounting and display flexibil- ity.
Installing the Device 2.3.1 Mounting the Device to a Rack 2.3.1 Mounting the Device to a Rack The RUGGEDCOM RSG2100P can be secured to a standard 48 cm (19 in) rack using separately purchased rack mount adapters. The adapters can be installed at the front or rear of the chassis.
Installing the Device 2.3.2 Mounting the Device on a DIN Rail Make sure the rack mount adapters are installed on the correct side of the chas- sis. • To make the modules and ports accessible, install the rack mount adapters at the rear of the chassis •...
Installing the Device 2.3.3 Mounting the Device to a Panel To mount the device to a DIN rail, do the following: Align the adapters with the DIN rails and slide the device into place. Panel/DIN Rail Adapter DIN Rail Screw Figure 2.2 DIN Rail Mounting Install one of the supplied screws on either side of the device to secure the adapters to the DIN rails.
Installing the Device 2.4 Connecting the Failsafe Alarm Relay To mount the device to a panel, do the following: Place the device against the panel and align the adapters with the mounting holes. Screw Panel/DIN Rail Adapter Figure 2.3 Panel Mounting Install the supplied screws to secure the adapters to the panel. Connecting the Failsafe Alarm Relay The failsafe relay can be configured to latch based on alarm conditions.
Installing the Device 2.5 Connecting Power Normally Open Common Normally Closed Figure 2.4 Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM RSG2100P supports a single AC or DC power supply, and a separate 48 VDC power supply for PoE ports. The RUGGEDCOM RSG2100P can be equipped with either a screw-type or pluggable terminal block , which provides power to the AC/DC power supply and PoE ports.
Installing the Device 2.5.1 Connecting AC or DC Power • Equipment must be installed according to applicable local wiring codes and stan- dards. 2.5.1 Connecting AC or DC Power To connect a single high AC, high DC or low DC power supply to the device, do the following: CAUTION Electrical hazard –...
Page 22
Installing the Device 2.5.1 Connecting AC or DC Power Connect the positive wire from the power source to the positive/live (+/L) termi- nal on the terminal block. Screw-Type Terminal Block Pluggable Terminal Block Jumper Positive/Live (+/L) Terminal Negative/Neutral (-/N) Terminal (-/N) Surge Ground Terminal Chassis Ground Terminal Figure 2.5...
Installing the Device 2.5.2 Connecting External PoE Power Using a #6 ring lug and #6-32 screw, secure the ground terminal on the power source to the chassis ground terminal on the device. Make sure the lug is tight- ened to 1.7 N·m (15 lbf·in). Stainless Steel Stud #6-32 Screw #6 Ring Lug...
Page 24
Installing the Device 2.5.2 Connecting External PoE Power Connecting the External Power Supply To connect an external power supply for the PoE ports, do the following: CAUTION Electrical hazard – risk of damage to equipment Only connect the external PoE power supply to the terminals 5 and 7. Remove the terminal block cover.
Installing the Device 2.5.3 Wiring Examples If the external PoE power supply features a chassis ground connection, connect the ground terminal on the power supply to terminal 4 on the terminal block. DANGER Electrocution hazard – risk of death, serious personal injury and/or damage to the device Make sure the supplied terminal block cover is always installed before the de- vice is powered.
Page 26
Installing the Device 2.5.3 Wiring Examples Figure 2.9 AC and 48 VDC PoE Power Supply RUGGEDCOM RSG2100P Installation Manual, 01/2020, C79000-G8976-1041-16...
Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RSG2100P console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM RSG2100P User Guide for the RUGGEDCOM RSG2100P. RS232 Console Port Connect a workstation directly to the RS232 console port to access the boot-time control and RUGGEDCOM RSG2100P interfaces.
Device Management 3.2 Configuring the Device Name Description Comment RJ45 Male DB9 Female Ring Indicator The DSR, DCD and DTR pins are connected together internally. The CTS and RTS pins are connected together internally. RI is not connected. Communication Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RSG2100P console and Web interfaces via the device's IP address.
Communication Ports The RUGGEDCOM RSG2100P can be equipped with various types of communication ports to enhance its abilities and performance. Module Assignment Figure 4.1 Module Assignment Each type of module has a specific location in the RUGGEDCOM RSG2100P chassis: • Slot 5 supports a pair of Gigabit Ethernet (1 Gbps) ports •...
Communication Ports 4.1 Copper Ethernet Ports LED State Description Yellow (Solid) Link established Yellow (Blinking) Link activity No link detected Port LED Figure 4.2 Port LEDs Copper Ethernet Ports The RUGGEDCOM RSG2100P supports several 10/100/1000Base-TX Ethernet ports that allow connection to standard Category 5 (CAT-5) unshielded twisted-pair (UTP) cables with either RJ45 or Micro-D male connectors.
Communication Ports 4.1 Copper Ethernet Ports Name Description 10/100Base-TX 1000Base-TX BI_DB+ Transmit Data+ or Bi- Directional Pair B+ Reserved (Do Not Connect) BI_DC+ Transmit Data+ or Bi- Directional Pair C+ Reserved (Do Not Connect) BI_DC- Receive Data- or Bi- Directional Pair C- BI_DB- Transmit Data- or Bi- Directional Pair B-...
Communication Ports 4.2 PoE Ports PoE Ports The RUGGEDCOM RSG2100P comes standard with two 10/100Base-TX Power over Ethernet (POE) ports powered by an external power supply. Each port complies with the IEEE 802.3af standard and features auto-sensing and automatic power off when cables are removed.
RUGGEDCOM SFP Transceiver Catalog [https://support.indus- try.siemens.com/cs/ww/en/view/109482309] NOTICE Only use SFP transceivers approved by Siemens for RUGGEDCOM products. Siemens accepts no liability as a result of performance issues related in whole or in part to third-party components. RUGGEDCOM RSG2100P...
To install a GBIC optical port, do the following: CAUTION Electrical hazard – risk of damage to equipment Use only components certified by Siemens with RUGGEDCOM products. Damage to the module and device may occur if compatibility and reliability have not been prop- erly assessed.
Page 36
Communication Ports 4.5.1 Installing a GBIC Optical Port CAUTION Electrical hazard – risk of damage to equipment Make sure all electrostatic energy is dissipated before installing or removing compo- nents from the device. An electrostatic discharge (ESD) can cause serious damage to the component once it is outside the chassis.
Communication Ports 4.5.2 Removing a GBIC Optical Port Release the latches and make sure the port is locked in place. NOTICE Only remove the dust plug when ready to connect a cable to the GBIC optical port. Remove the dust cover from the port and store for future use. Remove the dust cap from the cable and immediately connect it to the port.
Page 38
Communication Ports 4.5.2 Removing a GBIC Optical Port Store the port in an ESD-safe bag or other suitable ESD-safe environment, free from moisture and stored at the proper temperature (-40 to 85 °C or -40 to 185 °F). Insert a dust plug into the socket opening to prevent the ingress of dust and dirt. RUGGEDCOM RSG2100P Installation Manual, 01/2020, C79000-G8976-1041-16...
Page 39
Communication Ports 4.5.2 Removing a GBIC Optical Port RUGGEDCOM RSG2100P Installation Manual, 01/2020, C79000-G8976-1041-16...
Technical Specifications This section details the specifications and operating conditions of the device. Power Supply Specifications The RUGGEDCOM RSG2100P can be equipped with the following power supplies: CAUTION Electrical hazard – risk of power supply failure or damage to the device Make sure power input to the device is within the specified input range.
Note • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. • All optical power numbers are listed as dBm averages.
14.2 Typical. Typical distance. The maximum distance is greatly dependent on factors such as cable type, the number of connectors and number of splices. Consult a Siemens sales associates when determining maximum distances. Fast Ethernet (10/100 Mbps) Optical Specifications Mode...
Typical. Typical distance. The maximum distance is greatly dependent on factors such as cable type, the number of connectors and number of splices. Consult a Siemens sales associates when determining maximum distances. Operating Environment The RUGGEDCOM RSG2100P is rated to operate under the following environmental conditions.
UL 60950-1 Information Technology Equipment – Safety Part 1: General Requirements 6.1.2 European Union (EU) This device is declared by Siemens AG to comply with essential requirements and other relevant provisions of the following EU directives: • EN 60950-1 Information Technology Equipment – Safety – Part 1: General Requirements •...
Methods of Measurement The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens AG. For contact information, refer to "Contacting Siemens (Page vi)".
6.1.8 RoHS This device is declared by Siemens AG to meet the requirements of the following Ro- HS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: •...
Certification 6.1.9 Other Approvals 6.1.9 Other Approvals This device meets the requirements of the following additional standards: • IEEE 1613 IEEE Standard Environmental and Testing Requirements for Communications Networking Devices in Electric Power Substations • IEC 61000-6-2 Electromagnetic Compatibility (EMC) – Part 6-2: Generic Standards – Immunity for Industrial Environments •...
Page 52
Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels Severity Levels IEC 61000-4-6 Induced (Con- Signal Ports 10 V ducted) RFI DC Power Ports AC Power Ports Earth Ground Ports IEC 61000-4-8 Magnetic Field Enclosure Ports 100 A/m Continuous 1000 A/m for 1 s IEC 61000-4-11 Voltage Dips...
Certification 6.2 EMC and Environmental Type Tests Description Test Levels Enclosure Contact ±2 kV ±4 kV ±8 kV Enclosure Air ±4 kV ±8 kV ±15 kV Radiated RFI Enclosure Ports 35 V/m Fast Transient Signal Ports 4 kV @ 2.5 kHz DC Power Ports 4 kV AC Power Ports...
Page 54
Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels Severi- ty Level Bump 10 g @ 16 ms Class 1 60255-21-2 Seismic Method A, Class 2 Class 1 60255-21-3 RUGGEDCOM RSG2100P Installation Manual, 01/2020, C79000-G8976-1041-16...
Page 55
Certification 6.2 EMC and Environmental Type Tests RUGGEDCOM RSG2100P Installation Manual, 01/2020, C79000-G8976-1041-16...
Further Information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...